Home Companies Janson Controls Technologies (Shenzhen) Co.,Limited

Solar Water Pump VFD, off Grid Solar Inverter VFD With MPPT for 0.4KW~1132KW

Janson Controls Technologies (Shenzhen) Co.,Limited
Active Member

Contact Us

[China] country

Address: Gushu Industrial Park, Hangcheng Street, Xixiang Town,Baoan District, Shenzhen City, China

Contact name:Wade Wang

Inquir Now

Janson Controls Technologies (Shenzhen) Co.,Limited

Solar Water Pump VFD, off Grid Solar Inverter VFD With MPPT for 0.4KW~1132KW

Country/Region china
City & Province shenzhen guangdong
Categories Inverters & Converters
InquireNow

Product Details

SI200 series frequency inverter has the following features:

Closed-Loop Vector Control ( +PG Card)
Robust design, high start torque
Can do big kilowatt ( around 1300KW)
Infenion Brand IGBT Inside Only
Total failure ratio <1%.
Built In MODBUS
Built In C3 EMC Filter

 

Basic principle

Si200 solar pumping system can provide water for remote areas lacking of electricity or places where the electricity supply is unstable. PV pump controller can convert the DC power from solar panels to AC power so to drive various kinds of pumps.System enables continiously pumping when in good weather. System is not equipped with strorage battery devices, it is suggested that pumping the water to conservation pool
for future use.Water source could come from river, lake,well,or other natural water source or special soucre.System enables application of floating switch in the conservation pool or water tower to control the operation of pumps. Low water level probes can be installed in the well to detect the water level of the well in order to stop the pumps when the well in low water level. Diagram 1 is a typical SI200 PV pumping
system. The main parts and compenents of this system is after diagram 1.

 

 

 

General Purpose Series & Off Grid Solar Pump Inverters & Elevator Inverters
FC280 & SI200 & FC280E

 

Diagram Wire

 

 

SI200 PV Pump Controller input/output parameter
SI200-2SXXX

ModelSI200-2S-0.7SI200-2S-1.5SI200-2S-2.2
PV array input parameter
Max input voltage(V)DC 450V
Min input voltage(V)DC 180V
Recommended voltage(mpp)DC 280~360V
Recommended PV power(Kw)0.9 ~1.21.8~2.42.7~3.5
Spare AC generator
Input voltage ( V )Singel phase AC 200-240(+10%)
Max current(A)8.21423
Generator capacity(kVA)1.534
Output parameter
rated output voltage3-phase AC 200-240V
Max current(A)4.77.510
Rated output power(kW)0.751.52.2
Output frequency0~50Hz/60Hz


SI200-4TXXX Input/output parameter

ModelSI200-4T-2.2SI200-4T-3.7SI200-4T-5.5SI200-4T-7.5
PV array input parameter
Max input voltage(V)DC 800V
Min input voltage(V)DC 350V
Recommended
voltage(mpp)
DC 500~600V
Recommended
PV power(Kw)
2.7 ~3.54.8~6.46.6~8.89~12
Spare AC generator
Input voltage ( V )3-phase AC 380/400/415/440V(+15%)
Max current(A)5.810.514.620.5
Generator capacity(kVA)45.98.911
Output parameter
rated output voltage3-phase AC 380/400/415/440V(+15%)
Max current(A)5.191317
Rated output power(kW)2.23.75.57.5
Output frequency0~50Hz/60Hz
       
ModelSI200-4T-11SI200-4T-15SI200-4T-18.5SI200-4T-22
PV array input parameter
Max input voltage(V)DC 800V
Min input voltage(V)DC 350V
Recommended
voltage(mpp)
DC 500~600V
Recommended
PV power(Kw)
13.2~17.618~2422.2~29.626.4~35.2
Spare AC generator
Input voltage ( V )3-phase AC 380/400/415/440V(+15%)
Max current(A)263538.546.5
Generator capacity(kVA)17212430
Output parameter
rated output voltage3-phase AC 380/400/415/440V(+15%)
Max current(A)25323745
Rated output power(kW)111518.522
Output frequency0~50Hz/60Hz
         


 

ModelSI200-4T-30SI200-4T-37SI200-4T-45SI200-4T-55
PV array input parameter
Max input voltage(V)DC 800V
Min input voltage(V)DC 350V
Recommended
voltage(mpp)
DC 500~600V
Recommended
PV power(Kw)
36~4844~59.254~7266~88
Spare AC generator
Input voltage ( V )3-phase AC 380/400/415/440V(+15%)
Max current(A)627692113
Generator capacity(kVA)40576985
Output parameter
rated output voltage3-phase AC 380/400/415/440V(+15%)
Max current(A)607591112
Rated output power(kW)30374555
Output frequency0~50Hz/60Hz
       
ModelSI200-4T-75SI200-4T-90SI200-4T-110SI200-4T-132
PV array input parameter
Max input voltage(V)DC 800V
Min input voltage(V)DC 350V
Recommended
voltage(mpp)
DC 500~600V
Recommended
PV power(Kw)
90~12044~59.2132~176159~211
Spare AC generator
Input voltage ( V )3-phase AC 380/400/415/440V(+15%)
Max current(A)157180214256
Generator capacity(kVA)114134160192
Output parameter
rated output voltage3-phase AC 380/400/415/440V(+15%)
Max current(A)150176210253
Rated output power(kW)7590110132
Output frequency0~50Hz/60Hz
       



 

ModelSI200-4T-160SI200-4T-200SI200-4T-220SI200-4T-250
PV array input parameter
Max input voltage(V)DC 800V
Min input voltage(V)DC 350V
Recommended
voltage(mpp)
DC 500~600V
Recommended
PV power(Kw)
192~256240~320264~352300~400
Spare AC generator
Input voltage ( V )3-phase AC 380/400/415/440V(+15%)
Max current(A)307385430468
Generator capacity(kVA)231250280355
Output parameter
rated output voltage3-phase AC 380/400/415/440V(+15%)
Max current(A)304377426465
Rated output power(kW)160200220250
Output frequency0~50Hz/60Hz
       
ModelSI200-4T-280SI200-4T-315SI200-4T-355SI200-4T-400
PV array input parameter
Max input voltage(V)DC 800V
Min input voltage(V)DC 350V
Recommended
voltage(mpp)
DC 500~600V
Recommended
PV power(Kw)
192~256240~320264~352300~400
Spare AC generator
Input voltage ( V )3-phase AC 380/400/415/440V(+15%)
Max current(A)525590665785
Generator capacity(kVA)396445500565
Output parameter
rated output voltage3-phase AC 380/400/415/440V(+15%)
Max current(A)520585650725
Rated output power(kW)280315355400
Output frequency0~50Hz/60Hz
       

 

Model : ( Three-Phase 380V Range: -15%~20%)


Inverter Model
Capacity PowerInput CurrentOutput CurrentAdoptable Motor
FC280-4T-0.7G1.5KVA3.4A2.3A0.75KW
FC280-4T-1.5G3.05.03.71.5
FC280-4T-2.2G4.05.85.12.2
FC280-4T-4.0G5.910.58.54.0
FC280-4T-5.5G8.914.6135.5
FC280-4T-7.5G1120.5177.5
FC280-4T-11.0G1726.02511
FC280-4T-15G2135.03215
FC280-4T-18.5G2438.53718.5
FC280-4T-22G3046.54522
FC280-4T-30G4062.56030
FC280-4T-37G5776.07537
FC280-4T-45G6992.09145
FC280-4T-55G8511311255
FC280-4T-75G11415715075
FC280-4T-90G13418017690
FC280-4T-110G160214210110
FC280-4T-132G192256253132
FC280-4T-160G231307304160
FC280-4T-185G255333330185
FC280-4T-200G287380377200
FC280-4T-220G311429426220
FC280-4T-250G355470465250
FC280-4T-280G396525520280
FC280-4T-315G439605600315
FC280-4T-350G479665660350
FC280-4T-400G530730725400
FC280-4T-450G600825820450
FC280-4T-500G660910900500

 

Products Specifiction:
 

Basic FunctionSpecification
Maximum output frequency0~600Hz
Carrier frequency2.0kHz~10kHz;According to the load characteristics, carrier
frequency can be adjusted automatically
Input frequency resolutionDigital setting : 0.01Hz Analog setting : Maximum frequency x0.025%
Control mode0:V/F 1:Vector mode 0 control
Speed range1:50(Vector mode 0 ) 1Hz/150% rated torque
Overload capabilityG type:150% rated current for 60s;
P type:110% rated current for 60s.
Torque boostAuto Torque boost Manual Torque boost ; 0.1%~20.0%.
V/F curveFour modes : Line , Multi-point , Square V/F curve,V/F separation
Jog controlJog frequency range:0.00Hz to F00.03(Max frequency)
Accelerate/Decelerate curveLine or S-curve Acc/Dec mode ,four kinds of Acc/Dec time Range
of Acc/Dec Time0.0~6000.0s.
DC brakeDC brake frequency : 0.00Hz to Maximum frequency
brake time : 0.0 to 100.0s
brake current value : 0.0 to 150%
Simple PLC, Multi-speed16-speed operating through built-in PLC or control terminal
Built-in PIDClose loop control system can be formed easily by using PID
Automatic voltage
regulating (AVR)
Output voltage is regulated when voltage of the power network
changes
Overvoltage and overcurrent
stall control
During operation automatically limits the inverter output current
and bus voltage, to prevent fan overcurrent and overvoltage trip.
Rapid current limiting
function
Minimizing flow failures, protect the normal operation of the
inverter
Instantaneous stop non-stopLoad feedback energy compensation voltage is reduced and continue
to maintain a short time when change is momentarily interrupted.
Speed tracking startFor high-speed rotation of the motor speed identification, impact-
free smooth start
Rapid current limitRapid software and hardware limiting technology to avoid
frequent converter overcurrent fault.
Virtual IOFour sets of virtual DO,five sets of virtual DI, enables easy logic
control.
Timing ControlTiming control: set the time range 0.0Min~6500.0Min
Multi-motor
switch
Two independent motor parameters, enabling two motors switching control
Bus SupportTwo independent Modbus communication, Profibus-DP
Motor overheating
protection
Optional IO expansion card 1, analog input T_Motor(AI5) acceptable the input of
motor temperature sensor .(PT100,PT1000)
Command sourceGiven the control panel, control terminal, serial communication port given. It
can be switched by a variety of ways.
Torque boostAuto Torque boost Manual Torque boost ; 0.1%~20.0%.
Frequency sourceEleven kinds of frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, or serial port and so on. It can be switched by a variety of ways.
Auxiliary
frequency source
Eleven kinds of auxiliary frequency source. Flexible implementation of auxiliary
frequency tuning, frequency synthesis.
Input terminalStandard:
Six digital input terminals, one only supports 50khz high pulse input
Three analog input terminals,two support -10V~10V voltage input
One support 0 ~ 10V voltage input or 0 ~ 20mA current input
Expansion capability:
Two digital input terminals
One analog input terminal, support -10V ~ 10V voltage input, and supports
PT100 / PT1000
Output
terminal
Standard:
One high-speed pulse output terminal (optional open collector type), support of
square wave 0 ~ 50kHz signal output
One digital output terminal
Two relay output terminals
Two analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V
voltage output
Expansion capability:
One digital output terminal
One relay output terminal
One analog output terminal, support 0 ~ 20mA current output or 0 ~ 10V voltage
output
Display and operation
LED displayDisplay parameters and status information
The key lock and function
selection
Achieve some or all of the keys locked, scope definition section keys
to prevent misuse.
Protection functionInput/output phase failure protection ,Overcurrent protection ;Over
voltage protection; Undervoltage protection; Overheat protection ;
Overload protection
OptionsBrake assembly, simple IO expansion cards, multi-IO expansion card
Environment

Hot Products

FC100 series AC drive is a compact small power AC drive. It is an economic model specialized for the ...
FC100 series AC drive is a compact small power AC drive. It is an economic model specialized for the ...
FC100 series AC drive is a compact small power AC drive. It is an economic model specialized for the ...
FC100 series AC drive is a compact small power AC drive. It is an economic model specialized for the ...
FC100 series AC drive is a compact small power AC drive. It is an economic model specialized for the ...
FC100 series AC drive is a compact small power AC drive. It is an economic model specialized for the ...