Home Companies Forsentek Co., Limited

Universal S Type Tension Load Cell 3kN 2kN 1kN 500N 300N 200N 100N 50N

Forsentek Co., Limited
Active Member

Contact Us

[China] country

Address: 2# Jinlong Rd. Baolong Industrial Zone, Longgang Dist. Shenzhen China 518000

Contact name:Tarik Lu

Inquir Now

Forsentek Co., Limited

Universal S Type Tension Load Cell 3kN 2kN 1kN 500N 300N 200N 100N 50N

Country/Region china
City & Province shenzhen guangdong
Categories Other Chargers
InquireNow

Product Details

Universal S Type Tension Load Cell 3kN 2kN 1kN 500N 300N 200N 100N 50N

Universal s-beam Tension Load Cell FS6A/FS6B is strain gauge based intended for tension and compression force measurement. S Type Load Cell FS6A/FS6B offers 0-50N / 0-100N / 0-200N / 0-300N / 0-500N / 0-1000N / 0-2000N / 0-3000N eight rated measuring ranges to choose from. M8/M12 metric threaded holes located on both ends can be used to mount attachments such as eye bolts and hooks for adapt to different cases. S Type Force Transducer FS6A/FS6B offers an accurate and affordable measuring solution for applications such as material testing machines, hanging scales, hopper weighing, automation equipment and so on.

s beam tension load cell 3kN 2kN 1kN 500N 300N 200N 100N 50N
Dimensions
s beam force sensor 3kN 2kN 1kN 500N 300N 200N
Specifications

Capacity

5kg / 50N / 11 lb

10kg / 100N / 22lbf

20kg / 200N / 44lb

30kg / 300N / 66 lbf

50kg / 500N / 110lbf

100kg / 1kN / 220 lb

200kg / 2kN / 440lbf

300kg / 3kN / 660 lb

Rated output2.0mV/V
Excitation3-15V
Zero balance±0.05mV/V
Nonlinearity±0.05% R.O.
Hysteresis±0.05% R.O.
Nonrepeatability±0.03% R.O.
Creep(5min)±0.03% R.O.
Safe overload150% F.S.
Ultimate overload200% F.S.
Compensated temperature-10...+40oC
Operating temperature-20...+60oC
Temperature shift zero±0.05% R.O./10oC
Temperature shift span±0.05% R.O./10oC
Input resistance385±50 ohms
Output resistance380±30 ohms
Insulation resistance>5000M ohms
Ingress protectionIP50
Material of elementAlloy steel
CableØ5.5*2000mm 4-core shielded
Wiring code

Red--Excitation+ Black--Excitation-

Green--Signal+ White--Signal-

 

Load cell glossary:

Wheatstone Bridge:A Wheatstone bridge is a network of four resistive legs. One or more of these legs can be active sensing elements. The Wheatstone bridge is the electrical equivalent of two parallel voltage divider circuits. R1 and R2 compose one voltage divider circuit, and R4 and R3 compose the second voltage divider circuit. The output of a Wheatstone bridge is measured between the middle nodes of the two voltage dividers.
Excitation: The voltage applied to the input terminals of the load cell.

Rated Capacity: The maximum axial load the load cell is designed to measure within its specifications.

Non-linearity: The maximum deviation of the calibration curve from a straight line drawn between the no-load and rated outputs; expressed as a percentage of the rated output and measured on increasing load only.

Non-repeatability: The maximum difference between load cell output readings for repeated loadings under identical loading and environmental conditions.

Hysteresis: The maximum difference between load cell output readings for the same applied load; one reading obtained by increasing the load from zero and the other by decreasing the load from rated output; usually measured at half rated output and expressed in percent of rated output.

Creep: The change in load cell output occurring with specified period of time, while under load, and with all environmental conditions and other variables remaining constant; usually measured with rated load applied.

Safe Overload: The maximum load in percent of rated capacity which can be applied without producing a permanent shift in performance characteristics beyond those specified.

Ultimate Overload: The maximum load in percent of rated capacity which can be applied without producing a structural failure.

Operating Temperature: The extremes of temperature within which a load cell will operate without permanent adverse change to any of its performance characteristics.

Temperature Shift Span: The change in output due to a change in load cell temperature; usually expressed as a percentage of load per degree Celsius change in temperature.

Temperature Shift Zero: The change in zero balance due to a change in ambient temperature; usually expressed in percent of rated output per degree Celsius change in temperature.

Input Resistance: The resistance of the load cell bridge circuit measured at the positive and negative excitation terminals with no load applied and with the output terminals open-circuited.

Output Resistance: The resistance of the transducer bridge circuit measured at the positive and negative signal terminals with no load applied and with the input terminals open-circuited.

Universal S Beam Tension Load Cell Force Transducer 3kN 2kN 1kN 500N 300N 200N 100N 50N
S type force transducer 3kN 2kN 1kN 500N 300N 200N 100N 50N

Click here to download datasheet

Hot Products

Flange Style Tension Compression Load Cell 200kg 100kg 50kg 20kg 10kg 5kg 2kg Miniature Flange-to...
Multi Axis Load Cell 50kN 30kN 20kN 10kN 5kN 3kN 3-Axis Force Sensor 3-Axis Load Cell F3H/F3J is ...
Smallest Load Cell Sensor 2kg 5kg 10kg Smallest Weight Measurement Transducer Smallest Weight Sensor ...
Miniature Force Transducer 10N 20N 50N 100N 200N 500N Tension Compression Sensor Miniature Force ...
Micro Force Sensor 10N 20N 50N 100N 200N 500N Miniature Load Cell Tension Compression Miniature Load ...
M16 threaded Load Cell 500N 1000N 2000N 3kN 5kN 10kN Compression Force Measurement M16 threaded ...