KCS540 Infrared CO2 Module

 

 

 

1. overview

KCS540 is a gas detection module based on the principle of NDIR infrared absorption, which is suitable for detecting the concentration of carbon dioxide in a gaseous environment at room temperature.

KCS540 adopts a patented optical cavity, imported light source and dual-channel detector to achieve dual optical path reference compensation in space. KCS540 has good selectivity, no oxygen dependence and long life.

KCS540 has UART, IEC digital output, analog voltage output and PWM frequency output mode, which is convenient for customers to choose the application; The KCS540 provides zero calibration, sensitivity calibration, and clean air calibration commands, and provides customers with a manually calibrated MCDL pin to facilitate the relative zero calibration of the sensor module using outdoor free-flowing clean air. KCS540 adopts diffusion ventilation method, which has a fast diffusion speed.

KCS540 can be widely used in HVAC fresh air control, indoor air quality monitoring, agricultural and animal husbandry production process monitoring, can be installed in intelligent buildings, ventilation systems, robots, automobiles and other applications. It can also be applied to other confined spaces for air quality monitoring.

 

 

 

 

KCS540 diffusion exterior view

 

 

 

 

 

 

KCS540 pump suction exterior view

 

 

 

2. Technical parameters

 

 

parametersymbolminimumTypical valuesmaximumunit
Storage temperatureTstg-20-80°C
Operating temperatureTA-20 60°C
Operating humidityHA0 90% RH
Work pressurePA0.8 1.2atm
Supply voltageVs91218V
Maximum operating currentImax100120150mA
Detection range 20050000100% vol can be customizedppm
Measurement accuracy-± 50ppm or ±3% true value± 300ppm± 3% trueppm 
T90diffusion-3060second
Repeatabilityzero  <±50 ppm
50% FS- <± 2% of the measured value- 
Life Span 31015year

 

 

3. Structural Dimension Drawing

Unit: mm

                                                               

 

 

 

Diffusion

 

                                         

Pump-suction type

 

4. Installation instructions

The sensor is mounted with a positioning hole spacing of 44.5mand a mounting hole diameter of 2.8 mm

The wiring socket spacing is 2.54 m m

Note: SW400PV3.01, mounting aperture: 3.2mm

5. Matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, it is recommended that it be no more than 3 months, and calibration is not required on the long-term operation side if automatic calibration is turned on

Do not use the sensor for a long time in an environment with a high density of dust

Please use the sensor within the range of the sensor's power supply

6. Ordering instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name

2) Sensor range

3) Sensor measurement accuracy such as SW400, 0-2000pp

 

 

8 Order Information

Order information sheet
KCS540KCS540 CO2 concentration sensor
 xxxxThe sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000Range 200ppm (default).
10000Range 10000ppm
50000Range 50000ppm
 encodeThe reaction speed is divided into two types: fast and slow
SSlow (default).
Qfast
 encodeBaud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
CustomConfirm the baud rate before ordering
24002400bps baud rate
96009600bps baud rate
1920019200bps baud rate
3840038400bps baud rate (default)
 encodeSerial port protocol
Modbus-RTUStandard Modbus-RTU protocol (default).
Modbus-ASCIIStandard Modbus-ASCII protocol
Modbus-SelfModbus private protocol
KCS540-2000-S-38400-Modbus-RTU 

 

9. Ordering Instructions

URL: www.kacise.com

Tel: +86-29-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, Xi'an City, Shaanxi Province, China

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appendix

 

ShorthandFull name
VOL1% VOL refers to 1% of the volume of a particular gas in air.
PPM1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2Oxygen molecules
LCDLCD display
RS485Asynchronous serial port 485
DCdirect current
ACCommunication
PVCpolyvinyl chloride

 

Hot Products

1. Description KPS110 pressure and temperature integrated transmitter is a temperature and pressure ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Features 1) ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...