Home Companies Xi'an Kacise Optronics Co.,Ltd.

0.8-1.2 atm SF6 Gas Detector Sensor Ir Sensor Module 1500ppm

Xi'an Kacise Optronics Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Contact name:Evelyn Wang

Inquir Now

Xi'an Kacise Optronics Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

0.8-1.2 atm SF6 Gas Detector Sensor Ir Sensor Module 1500ppm

Country/Region china
City & Province Shaanxi
InquireNow

Product Details

KSS524 Infrared SF6 Gas Sensor Module

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 1 Version history

versiondatedescription
V1.02016-10-12V1.0 released
V2.22018-03-06Adapt product attribute modifications

 

 

 

 

 

 

Table of Contents

1.Overview....................................................................................................................... 4

2. Technical Parameters............................................................................................ 5

3. Structural dimension drawing................................................................................ 6

4. Signal output....................................................................................................... 6

5. Installation instructions....................................................................................... 11

6. Problems that should be paid attention to in maintenance...................................... 11

7. Ordering instructions.......................................................................................... 11

8. Ordering Information.......................................................................................... 12

9. Contact Details................................................................................................... 13

 

 

 

1.Overview

 

SF6 gas is widely used as an insulating medium and arc extinguishing gas in power equipment, especially in high-voltage circuit breakers, transformers, transformers, capacitors, arresters, fuses, etc. If leakage occurs, the pressure of the equipment is reduced and the insulation capacity is reduced; Pollute and destroy the atmospheric environment, increase the greenhouse effect; Accumulation in low-level spaces, resulting in accidents such as lack of oxygen in the brains of staff and even rapid asphyxiation; Under the influence of partial discharge, high temperature and other factors, SF 6 gas will produce highly toxic decomposition substances such as SF 4, SF 2, SOF2, etc.

KSS524 is a gas sensor module using NDIR infrared absorption detection principle, which determines the concentration according to the absorption of SF6 gas at 10.5um. KSS524 adopts MEMS light source, optical cavity with special structure and dual-channel detector to realize spatial dual-optical path reference compensation, and microprocessor for signal acquisition, processing and output. KSS524 has a UART digital interface to run Modbus ASCII protocol, which is compatible with Smartgas' modules; Provides digital calibration zero and sensitivity functions, and manually implements calibration zero function.

KSS524 can be widely used in SF6 gas leak detection and other occasions SF6 gas concentration analysis in the power industry.

 

 

KSS524 diffusion KSS524 pump suction type

 

 

2. Technical Parameters

 

 

parametersymbolminimumTypical valuesmaximumunit
Storage TemperatureTstg-20-80°C
Operating TemperatureTA-20 60°C
Operating HumidityHA0 90% RH
Work PressurePA0.8 1.2atm
Supply VoltageVs 911V
Maximum Operating CurrentIavg100120150mA
Range (customizable)  1500 ppm
Measurement AccuracyAcurracy ± 5ppm or ±2% true value is the greater %vol
T90Pump Suction  5 second
Diffusion 30 second
RepeatabilityZero  <±50 ppm
50%F.S.  

<±5%.

Measurements

  
Life Span  10 year

 

 

 

 

3.Structural dimension drawing

 

 

 

 

 

 

 

4.Installation instructions

The sensor is installed with a reference structure diagram with a positioning hole spacing and an aperture of 3.2mm

The wiring socket spacing is 2.0mm

5.Problems that should be paid attention to in maintenance

The sensor should be calibrated regularly, it is recommended that it be no more than 3 months, and calibration is not required if automatic calibration is turned on for long-term operation

Do not use the sensor for a long time in an environment with a high density of dust

Please use the sensor within the range of the sensor's power supply

6.Ordering instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name 2) Sensor range 3) Sensor measurement accuracy

For example, KSS524, 0-1500ppm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.Ordering Information

 

Order information sheet
KSS524KSS524 infrared SF6 gas sensor module
 xxxxThe sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000Range 200ppm (default).
10000Range 10000ppm
50000Range 50000ppm
 encodeThe reaction speed is divided into two types: fast and slow
SSlow (default).
Qfast
 encodeBaud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
CustomConfirm the baud rate before ordering
24002400bps baud rate
96009600bps baud rate
1920019200bps baud rate
3840038400bps baud rate (default)
 encodeSerial port protocol
Modbus-RTUStandard Modbus-RTU protocol (default).
Modbus-ASCIIStandard Modbus-ASCII protocol
Modbus-SelfModbus private protocol
KSS524-2000-S-38400-Modbus-RTU 

 

 

 

8.Contact Details

URL: www.kacise.com

Tel: +86-29-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, Xi'an City, Shaanxi Province, China

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appendix

 

ShorthandFull name
VOL1% VOL refers to 1% of the volume of a particular gas in air.
PPM1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2Oxygen molecules
LCDLCD display
RS485Asynchronous serial port 485
DCdirect current
ACCommunication
PVCpolyvinyl chloride

 

 

 

 

 

 

Hot Products

1. Description KPS110 pressure and temperature integrated transmitter is a temperature and pressure ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Features 1) ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...