Product Description

The stress and strain of the steel wire rope have a nonlinear corresponding relationship in the bending condition. The wire rope vibration isolator is to make the wire rope have a certain bending shape through a strong method, and use the internal friction to dissipate the vibration and impact energy when the wire rope is deformed by force, so as to eliminate vibration, reduce impact and reduce noise.
The wire rope vibration isolator is a high performance shock absorber and vibration isolator with nonlinear stiffness. Excellent vibration isolation performance under harsh environmental conditions such as chemical contamination or extreme temperatures. It has a long service life, can adapt to elastic displacements of various sizes, can realize vibration isolation in all directions, and has various installation methods.
It is usually used to provide elastic support for heavy machinery (such as generators, large hydraulic presses, rocket launch bases, etc.), to provide shock absorption protection for the transportation of large equipment such as precision instruments, missiles, aircraft, tanks and satellites, and for vehicle, ship, aircraft, etc. Carry precision equipment, precision instruments, and provide a vibration-isolated working environment.

Product Size Chart

Product numberHigh(mm)Width(mm)Product weight(kg)Installation methodHole size(mm)Thread size(mm)Counterbore taper
JGX-286-8-X-16860-A-S178± 6.3521620.9A, B, C, D, E, SØ19.8 + 0.13- 0.38M18X2.590°

 

Press Fit Test Data Sheet

Curve numberProduct numberStatic load(N)Maximum deformation (mm)Vibration stiffness Kv kN/mImpact stiffness Ks kN/m
1JGX-286-8-X-16860-A-S1686067.327061044

 

45° Inclined Press Fitting Load Test Data Sheet

Curve numberProduct numberStatic load(N)Maximum deformation (mm)Vibration stiffness Kv kN/mImpact stiffness Ks kN/m
1JGX-286-8-X-16860-A-S1197096.51541518

 

Shear Rolling Load Test Data Sheet

Curve numberProduct numberStatic load(N)Maximum deformation (mm)Vibration stiffness Kv kN/mImpact stiffness Ks kN/m
1JGX-286-8-X-16860-A-S632071.1636

636

 

Wire rope vibration isolators have the following advantages:
1: With nonlinear stiffness
2: All-round shock absorption
3: The resonant frequency is low, and the low-frequency shock absorption effect is good
4: Corrosion resistance, high and low temperature resistance, can continue to work in harsh environments
5: Easy installation, maintenance-free, long service life

Product Size Chart

Guide for installation of wire rope isolator

1. Before installation, please carefully check whether the mounting hole matches the mounting hole of the vibration isolator, such as whether the thread is the same, etc.

2, the installation hole is clean, there is no burr, rust, damage and other defects.

3. Since the vibration isolator is an elastic component, it needs a little movable space when working. Before installation, please carefully check whether there is any equipment affecting installation in the installation part and whether the movable space of the vibration isolator is enough. Please check whether the vibration isolator is in good condition and has no defects before installation.

4. Prepare a suitable screwdriver and crowbar.

5, first install the isolator to heavy equipment or fixed equipment, installation screws do not need to tighten, so that the isolator can be slightly active.

6. Install the connecting device on the other side of the vibration isolator. If the mounting hole is slightly misaligned, you can move the vibration isolator or use a crowbar to align the mounting hole of the vibration isolator with the mounting hole of the equipment, and then screw the fixing screw.

7. After fixing the device position, tighten all the fixing screws.

Application

Hot Products

1. Description KPS110 pressure and temperature integrated transmitter is a temperature and pressure ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Features 1) ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...