Home Companies Xi'an Kacise Optronics Co.,Ltd.

304 Stainless Steel DC24V Dissolved Oxygen Monitor Water Quality

Xi'an Kacise Optronics Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Contact name:Evelyn Wang

Inquir Now

Xi'an Kacise Optronics Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

304 Stainless Steel DC24V Dissolved Oxygen Monitor Water Quality

Country/Region china
City & Province Shaanxi
Categories Ice Tongs
InquireNow

Product Details

KFDO600 Low Cost Good Quality Dissolved Oxygen Meter Water Quality For Aquaculture 304 Stainless Steel Probe

Product Introduction
 
The fluorescence method dissolved oxygen measuring instrument is based on fluorescence quenching principle.The fluorescent material at the front of the sensor is a special platinum porphyrin compound with a polyester foil that allows gas molecules to pass through. The surface is coated with a black light-blocking material to avoid interference by sunlight and other fluorescent substances in the water.
When blue light hits the fluorescent material, the fluorescent material is excited and emits red light. Since oxygen molecules can carry away energy (quenching effect), the time and intensity of the excited red light are inversely proportional to the concentration of oxygen molecules.By measuring the phase difference between the excitation red light and the reference light and comparing with the internal calibration value, the concentration of oxygen molecules can be calculated.After linearization and temperature compensation, the final value is output.
 
 
 
Performance characteristics:
 
1. Principle of fluorescence quenching, no electrolyte digestion, maintenance-free
2. No need to replace the fluorescent cap, the use cost is lower;
3. No oxygen consumption, no flow rate and agitation requirements
4. No interference from chemicals such as sulfides
5. High resolution and measurement accuracy
6. Chinese menu operation is simple, easy to operate and master
7. Special thickened cap film, not easy to wear, longer service life
8. The unique protective cover design prevents irreversible damage caused by the cap film hitting hard objects during the sensor reuse process

 
 
 
Feathre Chart

 

 
 
 

Electrode installation

 

Electrodes are very delicate components and must be installed correctly. The wrong installation can result in damage to the electrodes or irreversible damage.The electrode is installed in pipeline.Immersion. Both French and French installations are available.

 

Do not put the electrode directly into the water. Instead, select the electrode mounting bracket or the flow cup for fixation.Before installation, please make sure to use the raw material belt (3/4 thread) to do waterproof sealing work, to avoid water entering into the electrode and causing short circuit of the electrode cable.

During water outage, make sure that the electrode is immersed in the tested liquid or wear the protective cap with the protective liquid inside. If the temperature is low and the water is stopped for a long time in winter, add antifreeze device or take back the room to add water and store.Otherwise, the service life will be shortened.
 
Technical Parameters of Fluorescence Dissolved Oxygen Analyzer
 

ClassPerformanceParameter
HostSupply VoltageAC220V or DC24V (choose one of the two)
Power Consumption<2W
DisplayLCD Chinese display/TFT color LCD (customized version)
Measuring range

0~100NTU,0~500NTU,0~5000NTU
0~10000NTU,0~25g/L,0~50g/L

Resolution0.01NTU,0.1NTU,1NTU,0.01mg/L
Precision2-3% calibration accuracy
Operating TemperatureTransmitter -10~65℃
MaterialPVC
Protection LevelI65/IP67(customized version)
Signal Output

485 communication/4-20mA analog output/support HART protocol/NB.GPRS.LORA

Communication (function option)

Installation MethodWall mount
SensorSupply VoltageDC5V
Protection Levelip68
Temperature0-60℃
Sensor Material304 stainless steel (input type), PVC (circulation type)
Cable LengthStandard 10 meters (extendable)
Operating Temperature0-60℃
Storage Temperature-10-60℃
Installation MethodBracket drop-in installation / flow-through wall-mounted installation.

 

 
Ordering Information selection table

 

 

Ordering Information selection table
KFDO600Fluorescence Dissolved Oxygen Meter
 Power supply
DC24V
AC220V
 Cable length
10m
15m
20m
30m
 Signal output
Only 4-20mA
Only 485

Also with 4-20mA , 485 signal output

 

Special custom signal
KFDO600-AC220V10mOnly 485

with AC220V adapter, cable between host and sensor,The cable length is 10 meters, the sensor is equipped without temperature compensation, and is equipped with only 485 communication signal output.
 

 

 
 
Q&A
 
What is zero drift?
It refers to the size of the indicating value of the automatic analyzer changing within a certain period of time when the zero correction liquid specified in this technical requirement is used as the sample for continuous testing.
 
What is Range drift?
refers to the change of the indicating value of the automatic analyzer in a certain period of time when the range correction liquid specified in this technical requirement is used as the sample for continuous testing.
 
What is Mean fail-free?
continuous running time refers to the ratio of the total running time (h) of the automatic analyzer to the number of failures (times) during the test period, which is shown in "MTBF". The unit is h/time.
 
What is response time (T90)?
electrodes from range correction fluid to zero correction fluid, the determination of displayed value range correction liquid concentration 90%.
 
 
Contact us

 
Website: www.kacise.com
Phone: +86-17719566736
Email: sales@kacise.com
Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
 


 
 
 
 
 
 
 

Hot Products

1. Description KPS110 pressure and temperature integrated transmitter is a temperature and pressure ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Features 1) ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...