Home Companies Xi'an Kacise Optronics Co.,Ltd.

Ip68 KPH500 PH/ORP Flexible Black PVC Water Quality Sensor

Xi'an Kacise Optronics Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Contact name:Evelyn Wang

Inquir Now

Xi'an Kacise Optronics Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Ip68 KPH500 PH/ORP Flexible Black PVC Water Quality Sensor

Country/Region china
City & Province Shaanxi
Categories Water Treatment
InquireNow

Product Details

KPH500 PH/ORP sensor,Compact, flexible and easy to use,black PVC,gray meter host,water quality test.

Production Introduction
The PH/ORP meter is a precision meter used to detect the pH/oxidation-reduction potential of liquids. It is designed with a microcomputer based on the principle of the primary battery and is simple to operate and easy to maintain. Not affected by color, turbidity, colloidal substances, oxidants and reducing agents, it is suitable for the determination of various media such as clean water, wastewater, industrial water, chemical reagents, etc., and is widely used in agriculture, environmental protection and industry.
 
 
 
The sensor uses a composite electrode, which can eliminate the influence of the inconstant "K" value,
A long-term, stable and accurate measurement of PH is realized. The internal structure of the sensor is shown on the right.
 
 

 
 

 
 

 

 
 
 

 

PH/ORP size structure chart
 
Host size
 
 
 

 
 
Sensor size
 

 

 

 

 


 

PH/ORP technical parameters
 
 
 

ClassPerformancePH parameterOPR parameter
HostMeasuring range0-14PH-2000mv-2000mv
Resolution0.01PH1mv
Precision2% Calibration accuracy
Operating TemperatureTransmitter 0-65℃
MaterialPVC
Protection LevelI65/IP67(customized version)
Signal Output

485 communication/4-20mA analog output/support HART protocol/NB.GPRS.LORA

Communication (function option)

Supply VoltageAC220V or DC24V (choose one of the two)
Power Consumption<1W
DisplayLCD Chinese display/TFT color LCD (customized version)
Installation MethodWall mount
SensorTemperature CompensationAutomatic temperature compensation
Protection Levelip68
Temperature0-60℃
Sensor MaterialPVC
Cable LengthDedicated PH cable, standard 5 meters (extendable)
Operating Temperature0-60℃
Storage Temperature-10-60℃
Installation MethodBracket drop-in installation

 
 
 
 

Ordering Information Selection Table
KPH500PH/ORP analyzer
Power supplyDC24V
AC220V
Cable length5m
10m
15m
20m
Temperature compensationSensor without temperature compensation
Sensor with temperature compensation
Signal outputOnly 4-20mA
Only 485
Also with 4-20mA , 485 signal output
Special custom signal
KPH500-P-DC24V-5m-Sensor without temperature compensation-Only 485PH host, with DC24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication.
KPH500-R-AC220V-10m-Sensor with temperature compensation-Only 485

Optional ORP host, with 220V adapter, line between host and sensor
The cable length is 10 meters, the sensor with temperature compensation, and is equipped with only 485 communication signal output.

 

Q&A

1.Does pH affect oxidation?

The dissolved oxygen concentration increases and because the reaction in the broth is an oxidation process, the redox is also increasing. Oxidation also increases with pH decreasing but why? When I am supplying oxygen for a long time, redox decreases as well as the pH also behaves the same way.

 

 

2.How can I lower my water ORP?

Lowering the pH to 6.0 raises the ORP, as more hypochlorous acid (HOCl) becomes available. Raising the pH to 8.0 lowers the ORP value, as more hypochlorite ions (OCl–) are present. Maintaining constant pH but adding more chlorine raises the ORP to a plateau of 900 to 950 mV, generally around 25 ppm HOCl.

 

 

3.What is pH?

pH is a measure of how acidic/basic water is. The range goes from 0 to 14, with 7 being neutral. pHs of less than 7 indicate acidity, whereas a pH of greater than 7 indicates a base. The pH of water is a very important measurement concerning water quality.

 

4.What does ppm stand for in pools?

parts per million

By Steve Donohoe. As pool service guys, we use the term parts per million several times a day when checking the chemical parameters of a swimming pool. It's the unit of measure that we use for the amount of chlorine, alkalinity, salt, TDS, cyanuric acid, and so on.

 

5.Is pH 10 Water Safe?

There has been no evidence of harm found in drinking water with a pH of between 7 and 8.5. (Interesting to note: The pH of human blood is a little on the basic side, 7.365.) When the PH of water becomes greater than 8.5, water taste can become more bitter.

 

 

Contact us
Website: www.kacise.com
Phone: +86-17719566736
Email: sales@kacise.com
Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
 
 

Hot Products

1. Description KPS110 pressure and temperature integrated transmitter is a temperature and pressure ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Features 1) ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...