Mass Flow Meters Installation and Operation Manual

                                             

 

 

1.Introduction
Kacise Mass Flow Meters patented and developed by our company are the leading meters for precision flow measurement. And with good reason, the meters offer the most accurate measurement available for virtually any process fluid, while exhibiting exceptionally low pressure drop. The meters offer direct mass flow, volume flow, density, and temperature measurement of liquids and slurries — without the need for additional equipment, manual calculations, or estimations.
The meters are designed for unsurpassed performance in even the harshest operating environments. They have no moving parts, and any special mounting or flow conditioning requirements. Every meter is available with stainless steel wetted parts and a wide variety of process connections to meet your every need.
The meters carry hazardous area approval for P. R. China.

 

2.product feature
The instrument is based on the Coriolis Force principle and enables direct and accurate measurement of mass flow without any conversion, correction or modification of pressure, temperature, viscosity, or density. (Kg / h, t / h or g / s) are directly displayed on the electronic unit panel and output on the back of the electronic unit. 0-10kHz, 4- 20mA and RS485 communication protocol. The flowmeter has no moving parts, wide range, accuracy (± 0.2%), high pressure, wide temperature range, can be used to measure high viscosity (10000CP) and non-Newtonian fluid flow. The characteristics of the instrument in the oil field, refinery, chemical, building materials, food, medicine, leather, paper, paint, dyes, nuclear energy, metallurgy, aerospace and other sectors are widely used. Flow sensor measurement tube 316L stainless steel or Kazakhstan C alloy material, the sensor components are not in contact with the medium, good corrosion resistance.
Instrument installation using quick and easy, stable and reliable operation, is currently the most flow characteristics of many instruments, the most popular new mass flowmeter. The instrument according to intrinsically safe explosion-proof design and manufacture of national standards, explosion-proof mark for EX d ib IICT5Gb.

 

 

3.Typical application

 

4. Instrumentation dimensions

 

Instrumentation Dimensional Drawings                                                                             

 

                                                                                                                      

                                                                                                                             

Dimensions of large - scale instrument

 

Unit:mm

 

 

 

Model

Weld Neck Flanges-ANSI B16.5

 

 

A

 

 

B

 

 

C

 

 

E

 

 

F

 

 

W

 

 

G

 

 

K

 

 

d

 

 

D

DNLB
KMF-1-6c100150670510740858109226019.1190.5157.2228.6
KMF-1-6CD125150670510740858109226022.4215.9185.7254
KMF-1-6D1501508606709501130137028022.4241.3215.9279.4

 

Dimension of medium - sized instrument

 

ModelDimension of medium - sized instrumentABCEFWGKdD
DNPN(MPa)
KMF-1-3A104.02802102352854858014604190

 

 

ModellangeGB-/T 9112-9124- 2000ABCEFWGKdD
DNlb
KMF-1-3B153002802102753255258015.766.553595.2
KMF-1-420300290230325375575901982.542.9117.3
KMF-1-5A253004103004405006961201988.950.8123.9
KMF-1-5B4030052036048058579013022.3114.373.15155.4
KMF-1-6A5015055037054867087515319.1120.791.9152.4
KMF-1-6AB6515056044060071593620019.1139.7104.6177.8
KMF-1-6B8015060047065076798822019.1152.4127190.5

 

Miniature instrument appearance dimensions

 

Unit: mm

 

Model

Take over the

outside diameter

PN(MPa)ABCEFWG
KMF-1-1-A625160165180140150537
KMF-1-1-B825160165180140150537
KMF-1-2-A825175208245185188537

 

Micro - bending instrument appearance size

 

Unit:mm

 

ModelDNLHWH1
KMF-1-V-101055016068360
KMF-1-V-151558017068370
KMF-1-V-202064020068400
KMF-1-V-2525780320100520
KMF-1-V-5050900230108460
KMF-1-V-8080995260140515
KMF-1-V-1001001300350150605
KMF-1-V-1501501750490262805
KMF-1-V-2502501920510262825

 

Transmitter dimensions size

 

Unit:mm

 LL1L2L4L5L6L7L8L9H4
Transmitter1561251181305410218045.48532

 

Signal output and Power Supply

5. Installation method

 

 

Horizontal installation-Normal

 

Suitable for liquid measurement conditions ,To ensure that the gas may exist in the gas discharge

 

 

Horizontal installation-reverse

 

 

Suitable for gas measurement conditions,To ensure that the fluid may be condensate discharge

 

Flag installation with bypass

 

 

For liquids and high viscosity,High Temperature liquid,And requirefrequent emptying of the fluid from the pipeline

 

Flag installation simple

 

Be suitable for overflow conditions,But the Throttle device at the outlet of the flow meter is very important,If there is no throttle device may produce siphon effect,Affect the measurement of the fluid
 

6.Instrument Selection

 

Code: KMF-1- Product Flow meter selection guide
 CodeDN/Measuring range
 1ADiameter:3mm, 0-40kg/h
 1Bdiameter:6mm, 0-100kg/h
 2Adiameter:8mm, 0-200kg/h
 3Adiameter:10mm, 0-5000kg/h
 3Bdiameter:15mm, 0-1000kg/h
 4diameter:20mm, 0-3000kg/h
 5Adiameter:25mm, 0-10th/h
 5Bdiameter:40mm, 0-20th/h
 6Adiameter:50mm, 0-30th/h
 6ABdiameter:65mm, 0-50th/h
 6Bdiameter:80mm, 0-100th/h
 6Cdiameter:100mm, 0-150th/h
 6CDdiameter:125mm, 0-200th/h
 6Ddiameter:150mm, 0-500th/h
 6Ediameter:200mm, 0-800th/h
 6Fdiameter:250mm, 0-1000th/h
  Code Transmitter output
  A4-20mA(Instantaneous flow or density is optional); 0-10KHz(Instantaneous flow pulse signal); RS485 Modbus RTU; HART
   Code Transmitter housing
   BDie-cast aluminum alloy shell Wiring hole dimensions:M20*1.5
    Code Pressure rating
    161.6MPa
    404.0MPa
    xxSpecial customization:using this letter to ask for the customization, please inform the pressure rating
     Code Temperature rating
     A-50~150℃
     B-50~250℃
     C-50~350℃
     D-200~150℃
      Code Accuracy class
      N0.20%
      M0.15%
      H0.10%
       Code Pressure link
       FStandard Flanges GB/T 9123.1-2000 ANSI Weld Neck Flanges-ANSI B16.5
       WHealth type
       LWelding thread
       TCustomization
        Code Inspection certificate
        FFactory standard:factory test certificate
        IGB:third-party verification certificate
         Code Material
         AMeasuring tube:316L
         CMeasuring tube:Hastelloy
         FMeasuring tube:inner wall spray PTFE(for large diameter)
         TSpecial customization:using this letter to ask for the customization, please inform the pressure rating
          Code Transmitter
          AIntegrated type
          B(XX)Split type(cable length), with bracket
           Code Explosion-proof mark
           AExd II CT5 Gb
KMF-1-3b(0~800kg/h)AB40ANFFAB(10)ATypical Orders information

 

 

 

 

 

Hot Products

GXPS200 Piezoresistive Explosion-proof Pressure Transmitter Description Pressure transmitter is a ...
MPTD-5000 Melt Pressure Transducer (Sanitary) Description GX MPTD-5000 series Melt Pressure ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Features 1) ...
GXPS 4-20ma differential pressure transmitter GXPS500 4-20ma differential pressure transmitter 1. ...
GXPS353 Universal Pressure Transmitter / Industry High Accuracy Pressure Sensor Feature Accuracy: ±0...
GXPS600 Series ±0.5%F.S Accuracy Digital RS485 Digital output pressure sensor Pressure Transducer ...