Home Companies Xi'an Kacise Optronics Co.,Ltd.

KLD800 Series FMCW 80GHz Non Contact Radar Level Transmitter For Liquid And Solid

Xi'an Kacise Optronics Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Contact name:Evelyn Wang

Inquir Now

Xi'an Kacise Optronics Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

KLD800 Series FMCW 80GHz Non Contact Radar Level Transmitter For Liquid And Solid

Country/Region china
City & Province Shaanxi
InquireNow

Product Details

KLD800 Series FM CW 80GHz Non-contact Corrosion Resistant Lens Antenna Radar Level Transmitter For Liquid and Solid
 
Introduction

80GHz frequency modulation radar level transmitter is also called frequency modulation continuous wave (FMCW) radar level transmitter, which is a higher frequency radar level gauge. Its main advantages are smaller emission angle, more concentrated energy, stronger echo signal, stronger penetration, and higher measurement accuracy. It can be applied to various occasions and is more stable than other radar products.

It is effective in harsh conditions. Whether it is a toxic medium, or a corrosive medium, and whether it is a solid, liquid, dusty, or slurry medium, it can be measured.

 

Feature

1. More compact architecture, higher signal-to-noise ratio, and smaller blind spots.
2. Higher measurement resolution and measurement accuracy.
3. The narrowt 3° antenna beam angle, the interference in the installation environment will have less impact on the instrument, and the installation is more convenient.
4. The wavelength is shorter and has better reflection characteristics on solid surfaces, so there is no need to use special universal flanges for aiming.

5. Stable performance and long life. It can adapt to various environments and working conditions, and has strong corrosion resistance and anti-interference ability, and can work in various harsh working conditions.

6. Accurate, safe and energy-saving: The chemical and mechanical properties of the materials used in radar level gauges are quite stable, and the materials can be recycled, which is extremely environmentally friendly.

7. Maintenance-free and highly reliable: Microwaves are almost immune to interference and do not directly contact the measurement medium, so they can be used in almost all occasions, such as vacuum measurement, liquid level measurement or material level measurement, etc. Due to the use of advanced materials, it is durable to extremely complex chemical and physical conditions, and it can provide accurate, reliable, long-term stable analog or digital level signals.

 

 

Specification
KLD801Medium: liquid, non-corrosive
Measuring range: 0.05m~10/20/30/60/100m
Process connection: G1½A / 1½NPT thread / flange ≥ DN40
Process temperature: -40~80℃
Process pressure: -0.1~0.3 MPa
Antenna size: 32mm lens antenna
Antenna material: PTFE
Accuracy: ±2mm
Protection class: IP67
Center frequency: 80GHz
Launch angle: 3°
Power supply: Two-wire /DC24V
Four-wire system/DC12~24V
Four-wire system/AC220V
Casing: aluminum/plastic/stainless steel
Signal output: two-wire /4...20mA/HART protocol
Four-wire system: 4...20mA/ RS485 Modbus
KLD802Medium: non-corrosive liquid, slightly corrosive liquid
Measuring range: 0.1m~10/20/30/60/100m
Process connection: flange ≥ DN80
Process temperature: -40~110℃
Process pressure: -0.1~1.6MPa
Antenna size: 32mm lens antenna
Antenna material: PTFE
Accuracy: ±2mm (range below 35m)
±5mm (range between 35m and 100m)
Protection class: IP67
Center frequency: 80GHz
Launch angle: 3°
Power supply: two-wire /DC24V
four-wire /DC12~24V
four-wire /AC220V
Casing: aluminum/stainless steel
Signal output: two-wire /4...20mA/HART protocol
four-wire / 4...20mA/ RS485 Modbus
KLD803Medium: strong corrosive liquid, steam, foam
Measuring range: 0.1m~10/20/30/60/100m
Process connection: flange ≥ DN50
Process temperature: -40~130℃
Process pressure: -0.1~2.5MPa
Antenna size: 34mm lens antenna (according to flange size)
Antenna material: PTFE
Accuracy: ±2mm (range below 35m)
±5mm (range between 35m and 100m)
Protection class: IP67
Center frequency: 80GHz
Launch angle: 3°
Power supply: two-wire /DC24V
four-wire /DC12~24V
four-wire /AC220V
Casing: aluminum/stainless steel
Signal output: two-wire /4...20mA/HART protocol
four-wire 4...20mA/ RS485 Modbus
KLD804Medium: strong corrosive liquid, steam, foam
Measuring range: 0.1m~10/20/30/60/100m
Process connection: flange ≥ DN50
Process temperature: -40~130℃
Process pressure: -0.1~1.0MPa
Antenna size: 76mm lens antenna
Antenna material: PTFE
Accuracy: ±2mm
Protection class: IP67
Center frequency: 80GHz
Launch angle: 2°
Power supply: two-wire /DC24V
four-wire /DC12~24V
four-wire /AC220V
Casing: aluminum/plastic/stainless steel
Signal output: two-wire /4...20mA/HART protocol
four-wire 4...20mA/ RS485 Modbus
KLD805Medium: strong corrosive liquid, steam, foam,
high temperature. and high pressure
Measuring range: 0.1m~10/20/30/60/100m
Process connection: flange ≥ DN80
Process temperature: -40~200℃
Process pressure: -0.1~2.5MPa
Antenna size: 76mm lens antenna (according to flange size)
Antenna material: PTFE/overall filling
Accuracy: ±2mm
Protection class: IP67
Center frequency: 80GHz
Launch angle: 3°
Power supply: two-wire /DC24V
four-wire /DC12~24V
four-wire /AC220V
Casing: aluminum / plastic / stainless steel
Signal output: two-wire /4...20mA/HART protocol
four-wire 4...20mA/ RS485 Modbus
KLD806Medium: solid, storage container, process container,
strong dust application
Measuring range: 0.3m~10/20/30/60/100m
Process connection: flange ≥ DN100
Process temperature: -40~110℃
Process pressure: -0.1~0.3MPa
Antenna size: 76mm lens antenna (purge optional)
Antenna material: PTFE
Accuracy: ±5mm
Protection class: IP67
Center frequency: 80GHz
Launch angle: 3°
Power supply: two-wire /DC24V
four-wire /DC12~24V
four-wire /AC220V
Casing: aluminum/plastic/stainless steel
Signal output: two-wire /4...20mA/HART protocol
four-wire 4...20mA/ RS485 Modbus

 

KWL800 water level sensor

Transmit Frequency76GHz~81GHz
Measuring Range0.1 m ~ 65m
Measurement Accuracy±1mm
Beam Angle
Power Supply Range9~36 VDC
Communication MethodRS485
Operating Temperature-40~85℃
Shell MaterialPP
Antenna TypeLens antenna
Recommended Cable7*0.3mm²
ProtectionIP68
Installation MethodBracket

 

  
Installation Method

Thread installation (KLD801)


Flange installation 
When using flange installation, the minimum distance between the instrument and the tank
wall should be 200mm.
① datum plane
② vessel center or axis of symmetry
 
               
 
Hoisting Installation
         

     

 

Hot Products

30mm /1.2" aluminium glycerine freon hydraulic pressure gauge Product Description Application PGV ...
60mm /2.5" aluminium glycerine freon nitrogen pressure gauge Product Description Application PGV ...
50mm / 2" 316ss oil filled ammonia refrigerant pressure gauge Product Description Application PGV ...
50mm / 2" brass silicone oil filled refrigerant freon pressure gauge Product Description Application ...
60mm /2.5" brass silicone oil filled lpg ammonia pressure gauge Product Description Application PGV ...
China supplier high accuracy low price digital peak pressure gauge for pressure peak value recording ...