KLD806 80GHz Radar Level Transmitter with Air Purge for Solid Medium and Strong Dust Application
 
Introduction

The 80GHz FM level radar transmitter is especially suitable for industrial and mining environments with high temperature and high pressure or high dust and agitation spaces. It meets many measurement needs that require a large range and high precision.

KLD800 series level transmitter have the ability to penetrate non-polar substances. In the industrial environment with strong adhesion and strong dust, it has ideal measurement stability and environmental anti-interference ability.
This product is also due to its extremely small antenna beam angle and strong adaptive automatic gain function. The 80GHZ frequency modulation continuous wave radar uses FPGA chip hardware to realize fast Fourier transform calculation, making the measurement accuracy reach 0.217mm within 50 meters. KLD800 FM radar level transmitter adopts PTFE lens antenna full-seal potting design, and solves the structural treatment of antenna near-field radiation suppression, which makes it have good directivity performance.

 
Feature

1. Easy maintenance and simple operation: the radar level gauge has fault alarm and self-diagnosis functions. Analyze the fault according to the error code prompted by the operation display module, determine the fault in time and eliminate it, making maintenance and calibration more convenient and accurate, and ensuring the normal operation of the instrument.

2. It has a wide range of applications and can measure almost all media: from the shape of the tank body, the radar level gauge can measure the liquid level of spherical tanks, horizontal tanks, cylindrical tanks, cylindrical cone tanks, etc.; In terms of body functions, it can measure the liquid level in storage tanks, buffer tanks, microwave tubes, and bypass pipes. From the perspective of the measured medium, it can measure liquids, particles, slurry, etc.

3. Continuous and accurate measurement: The probe of the radar level gauge has no contact with the surface of the medium, which belongs to non-contact measurement, and can accurately and quickly measure different media. The probe is hardly affected by temperature, pressure, gas, etc.

4. Accurate, safe and energy-saving: The chemical and mechanical properties of the materials used in radar level gauges are quite stable, and the materials can be recycled, which is extremely environmentally friendly.

5. No maintenance and high reliability: Microwave is almost free from interference and does not directly contact with the measurement medium, so it can be used in almost all kinds of occasions, such as vacuum measurement, liquid level measurement or material level measurement, etc. Due to the use of advanced materials, it is durable to extremely complex chemical and physical conditions, and it can provide accurate, reliable, long-term stable analog or digital level signals.

 

Specification

 

Mediumsolid, storage container, process container, strong dust application
Measuring range 0.3m~10/20/30/60/100m
Process connection flange ≥ DN100
Process temperature -40~110℃
Process pressure -0.1~0.3MPa
Antenna size​ 76mm lens antenna (air purge optional)
Antenna material PTFE
Accuracy  ±5mm
Protection class IP67
Center frequency  80GHz
Launch angle 3°
Power supply two-wire /DC24V
  four-wire /DC12~24V
  four-wire /AC220V
Casing aluminum/stainless steel
Signal output two-wire: 4...20mA/HART protocol
  four-wire: 4...20mA/ RS485 Modbus

 
Product Dimension
Unit in mm:

  
Installation Method
Flange installation 
When using flange installation, the minimum distance between the instrument and the tank
wall should be 200mm.
① datum plane
② vessel center or axis of symmetry
 
               
 
Hoisting Installation
         

            
 

 


 

 

Hot Products

30mm /1.2" aluminium glycerine freon hydraulic pressure gauge Product Description Application PGV ...
60mm /2.5" aluminium glycerine freon nitrogen pressure gauge Product Description Application PGV ...
50mm / 2" 316ss oil filled ammonia refrigerant pressure gauge Product Description Application PGV ...
50mm / 2" brass silicone oil filled refrigerant freon pressure gauge Product Description Application ...
60mm /2.5" brass silicone oil filled lpg ammonia pressure gauge Product Description Application PGV ...
China supplier high accuracy low price digital peak pressure gauge for pressure peak value recording ...