Home Companies Xi'an Kacise Optronics Co.,Ltd.

RS485 Insurstial Wastewater Flow Meter , Magnetic Type Flow Meter High Accuracy

Xi'an Kacise Optronics Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Contact name:Evelyn Wang

Inquir Now

Xi'an Kacise Optronics Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

RS485 Insurstial Wastewater Flow Meter , Magnetic Type Flow Meter High Accuracy

Country/Region china
City & Province Shaanxi
Categories Pumps
InquireNow

Product Details

RS485 Insurstial Waste Water Treatment Electromagnetic Flow Meter Water Milk Beer Drink Water Flow Meter

 

 

Introduction


Electromagnetic flow meter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control. Electromagnetic flow meters are widely used in industrial sectors such as chemical industry, environmental protection, metallurgy, pharmaceutical, paper making, water supply and removal etc.
Besides measuring flow of general conductive liquid electromagnetic flow meter can measure flow of liquid-solid mixed fluid, high-viscosity fluid and salt, strong acid and strong alkali.

 

Features

 

1. Simple structures, firm, no movable parts and long operation life.

2. No intercepting fluid parts, no pressure loss and fluid clogging.

3. No mechanical inertia, quick response and good stability, application in automatic examination, adjustment & controlling.

4. Measuring accuracy not influenced by physical parameters such as style, temperature, viscosity, density and pressure.

6. Supply many styles of flow meters such as inline type and insertion type, etc.Adopt EEPROM memory to measure operation data, safe and reliable protection of memory.

7. High pressure sensor with PFA liner is resistant to high pressure and negative pressure, and available to chemistry and corrosive solution.

8. It is applicable not only to general process, but also in tough applications such as mining, papermaking, pastry, etc.

 

Parameters

Main powerAC220V 50HZ / DC24V
Power consumption<15W (And set with sensor supporting power consumption )
Display and push buttonsThe big screen LCD display with back lighting can display the instantaneous flow ,total flow and percentage of flow as well as alarm display ,four thin-film touch nubs ,which is used to data set .
AccumulatorForward total quantity ,reverse total quantity

 

 

 

 

 

 

 

 

 

Output signal

 

Analog output

Bi-direction with two ways ,Isolation 0-10mA/4-20mA
Load resistor:0-10Ma;0-1.5KΩ;4-20Ma;0-750Ω
Frequency outputForward & reverse flow output with frequency range set between 1-5000Hz.The external voltage must be lower than 35V and the max output and the max output current is 50Ma when the transistor is turned on

 

 

Alarm output

Two outputs from the collectors of photoelectric isolate transistors are for alarm signals .The external voltage must be lower than 35V and the max output current is 250Ma when the transistor is turned on.Alarm status:Activates when the measured pipes are empty ,the excitation circuits are broken or the volume of flow rate exceeds the value designed limits.

 

 

 

Pulse output

For pulse output in forward and reverse flow measurement ,upper frequency of pulse output can be up to 5000 CP/S relevant value of pulse is from 0.0001 to 1.0 M3/P .The width of pulse can be set to 20ms or squired wave from automatically.The collector of transistor with photoelectric is open circuited.The external voltage must be lower than 35 V and maximum output current is 250Ma when the transistor is turned on .
Accuracy±0.5% of the value displayed ,±0.3% or ±0.2% are selectable.
Damping time constantContinuous variable from 0-100 s (90%)can be selected by group
CommunicationRS232 ,RS485 or HART Communication are selectable ,with lighting resistance
Power failureAn anti-failure clock is designed in the flow meter which can save the power failure records for 16 times (10 years)
Protection classIP65
Ex-proof MarkExd IIBT4

 

Electrode Material

Item Suitable medium
SS316LLiving water; wastewater; Corrovise water and Mud, etc;
Hastelloy BNon-oxidizing acids at concentrations less than 10%; NAOH Concentrations less than 50%
Hastelloy CMixed Acid and Oxidizing salts
TitaniumSalt and weak acid ;Not application; hydrochloric acid, nitric acid and other reducing acids
Tantalumhydrochloric acid(<40%);Sulfuric acid and Other oxidizing acids
PlantinumAlmost all acid-base salt solution But not application for aqua regia, except ammonium salt
Tungsten carbidePulp ;sewage ;slurry

 

 

 

 

 

 

 

 

 

 

 

Model selection

 

 

Application

Hot Products

GXPS400 Series High Accuracy Submersible Liquid Level Sensor Description GXPS400 series liquid level ...
GXPS400M Split Type High Accuracy Liquid Level Sensor GXPS400M is a split type liquid level sensor ...
Introduction GXPS353 series pressure transmitter is a high-volume, low cost OEM, civil & industrial ...
GXPS353 Refrigeration Industry pressure transmitter 1.Product Description GXPS353 series pressure ...
GXPS550 Female thread Internal thread differential pressure sensor with output 0-10V ​ Introduction ...
GXPS240 High-frequency Water Supply Pressure Transmitter Introduction GXPS240 series pressure ...