Home Companies Xi'an Kacise Optronics Co.,Ltd.

Sea Water Electromagnetic Flow Meter Transmitter Negative Pressure Resistant

Xi'an Kacise Optronics Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Contact name:Evelyn Wang

Inquir Now

Xi'an Kacise Optronics Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Sea Water Electromagnetic Flow Meter Transmitter Negative Pressure Resistant

Country/Region china
City & Province Shaanxi
Categories Flow Switches
InquireNow

Product Details

Sea water Electromagnetic Flow Transmitter Meter Negative Pressure Resistant Electromagnetic Flowmeter Flow Meter

 

Introduction

KEF series electromagnetic flow meters are intended for fluid measurement in most industries including Electromagnetic flow meters are widely used in industrial sectors such as chemical industry, environmental protection, metallurgy, pharmaceutical, paper making, water supply and removal etc.Besides measuring flow of general conductive liquid electromagnetic flow meter can measure flow of liquid-solid mixed fluid, high-viscosity fluid and salt, strong acid and strong alkali.Electromagnetic flow meter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control.There are two basic components of electromagnetic flow meter: 1) The Detector, which includes the flow tube, isolating liner and measuring electrodes, and 2) The Converter, which is the electronic device responsilbe for signal processing, flow calculation, display and output signals.The materials of construction of the wetted parts( liner and electrodes) should be appropriate for the specification on the intended type of of service. Revies of the compatibilities consistent with the shipment of each meter.

 

Features

 

1. LCD back light display with high clearness. (Option: LED back light display)

2. No intercepting fluid parts, no pressure loss and fluid clogging.

3. No mechanical inertia, quick response and good stability, application in automatic examination, adjustment & controlling.

4. Measuring accuracy not influenced by physical parameters such as style, temperature, viscosity, density and pressure.

6. Supply many styles of flow meters such as inline type and insertion type, etc.

Adopt EEPROM memory to measure operation data, safe and reliable protection of memory.

7. Integral type flow meters and remote type flow meters.

8. Simple structures, firm, no movable parts and long operation life.(Guarantee in 1 years)

 

 

Parameters

ItemsDescription
Suitable DiameterDN25~DN2600 (below DN25 non-standard)
Suitable FluidLiquid with conductive ratio more than 5 μs/cm
Measuring Range0.5~10m/s (extendable to 15m/s)
Upper Limit of Span0.5~10m/s. 1~5m/s recommended
Accuracy0.3% (Option), 0.5%, 1.0% of F.S..
RepeatabilityBelow 0.25%
Display of Converter

Display : Flow rate ( 4-digits), Totalizer (9-digits), Velocity, Alarm status

by LCD ( LED-option)

Scale unit: selectable of L/h, L/m, L/s, m3/h, m3/m, m3/s
Flow direction : selectable by program
3 Digits display below of decimal points.
K-factor: 5 digits.
Data logger for 2-3years.
Programming language: English, Korean(on request)
Mounting: Integral type; Remote Type
PowerAC: 220V, 50-60Hz; DC: +24V(Option)
Output Signals

4~20m ADC, load ≤ 750ohm,

0~3kHz, 5V with source and changeable width.

High terminal and effective frequency output

Voltage output:0-5 V DC

Conduit connectionM20 * 1.5 Thread
Communication InterfaceRS-232; RS-485; HART
Operation Pressure1.0MPa, 1.6MPa, 4.0MPa, 16MPa (Special)
Fluid Temperature-20°C~80°C, 80°C ~130°C, 130°C ~180°C Depending on Lining Material
Ambient TemperatureSensor -40°C ~80°C. transducer -15°C ~50°C
Ambient Humidity≤ 85%RH (at 20C)
Cable Outlet SizeM20×1.5
Power Supply220VAC±10%, 50-60Hz±1Hz, 24VDC±10%, Battery power (3-5years)
Power Consumption≤ 8W
Protection RatingsIntegral type: IP65. Remote type: sensor IP68, transducer IP65.
MaterialsElectrode

316L (stainless steel), Hastelloy C, Hastelloy B,

Titanium, Tantalum, etc.

 LinerPTFE, Soft rubber, Hard rubber, F46, FS, PUR.
Measuring tubeSUS 304
FlangeCarbone Steal
Ground ring316L (stainless steel), HC, Ti, Ta, Cu.
Connection of Flange

National Standard GB9119-88 (DIN2051, BS4504), JIS, ANSI. Screw.

Tri-clamp for sanitary application

Insertion type.

EX-proof protectionExde ib ii BT2
Quality controlISO9001-2008, CE

Model selection

 

 

Application

 

Hot Products

GXPS400 Series High Accuracy Submersible Liquid Level Sensor Description GXPS400 series liquid level ...
GXPS400M Split Type High Accuracy Liquid Level Sensor GXPS400M is a split type liquid level sensor ...
Introduction GXPS353 series pressure transmitter is a high-volume, low cost OEM, civil & industrial ...
GXPS353 Refrigeration Industry pressure transmitter 1.Product Description GXPS353 series pressure ...
GXPS550 Female thread Internal thread differential pressure sensor with output 0-10V ​ Introduction ...
GXPS240 High-frequency Water Supply Pressure Transmitter Introduction GXPS240 series pressure ...