Product Details

RS485 Ultrasonic Mud Level Meter 5-70M Sludge Interface Instrument

Product Description

Ultrasonic mud level meter, also known as ultrasonic sludge interface instrument, is designed for long-term reliable work in industrial and municipal field.

By analyzing ultrasonic emissions and water suspended solids echo, it can calculate the height of the sludge. It works when the sensor is immersed in water for 5-10cm.

Ultrasonic mud level meter is suitable for rivers, lakes, reservoir, waterway, port, deep sea underwater cross-section measurement, underwater topography measurement and navigation and underwater detecting, etc.

It can work continuously for 24 hours, and realize real - time data transmission.

 

Parameters

FunctionSplit Type
Range5m, 10m, 15m, 20m, 30m, 40m, 50m, 60m, 70m
Accuracy1%-3%
Resolution1mm or 0.1%(which is bigger)
DisplayEnglish LED Display
Analog OutputFour wire 4~20mA/510Ωload
Digital OutputRS485, RS232 (optional)
Relay Output4 way AC 250V/ 5A or DC 30V/ 5A (optional)
Power SupplyDefault: 24VDC, Optional: 220V AC+15% 50Hz
Environment TemperatureLED: -20~+60℃, Probe : -20~+80℃
Protection GradeLED: IP65, Probe: IP68
Cable Probe10m
InstallationThread or Flange

 

Installation 

 

 

Solid measurement

 

Installation flange

 

The installation method is the same as liquid measurement. It can install on the flange which joint the connected tube of container. The axis must aim to container outlet or perpendicular to the media surface, the probe should be able to come out of the connected-tube.

 

 

 

Operating instructions of Ultrasonic Level Difference Meter menu

 

The ultrasonic level difference meter which has Chinese and English menu and simple

setup, can meet different requirements from customer. Normally, after followed installation instruction, then set several parameters, it will start to work.

Simple operation:

1. Key: Our products can be debugged through three keys on the panel. Then, the measured value is showed by LED.

2. After switched on of our product, press the SET key for two second and enter the first level menu.

3. The height value of probe(No.1) inputs to the “reference zero 1”, the “reference zero 1"position can be found structure table in the menu. (the height of probe is the distance from the launch surface of probe to the bottom).

4. The height value of probe(No.2) inputs to the “reference zero 2”. the “reference zero 2"position can be found structure photo of the menu.

5. Set “4mA ”corresponds difference value and "20mA corresponds difference value.

  • 4mA corresponds difference value :output is 4mA, when the difference value equal to setting value.
  • 20mA corresponds difference value:output is 20mA, when the difference value equal to setting value.
  • “As the corresponds difference value and "20mA corresponds difference value, please check the structure photo of menu.

 

One. Application

Ultrasonic level difference meter (material, liquid), is used to measure height differences of level or material level in the two different of containers.

Three. Wiring

 

Electrical wiring of ultrasonic level difference meter

 

Terminal of ultrasonic level difference meter

 

Wiring instruction

 

Grounding: First ground terminal of instrument must be grounded actually. Do not share the ground terminal with other devices. Pick up 4th Terminal. Transducer:

  • Red: Trans_n transducer n
  • Blue: Temp n + temperature sensor +
  • Black: GND earth wire
  • single probe: n=1, double probes, n=1,2 Current:“current+”connect mA n+; “current-”connect mA n-/GND
  • single probe: n=1, double probes, n=1,2 Relay:RLlnA and RLnB show open; RLnA and RLnC show closed. Single probe: n=1,2 double probes, n=1,2,3,4
  • Power: power AC connect L, N power DC: 24V+ connect 24VDC+,GND connect 24VDC-

Note:

① Delay 1 is used for probe1 alarm, delay 2 is used for probe2 alarm.Delay 3 and delay 4 are used for difference alarm.


★ The output of mA1+ and mA- is difference current.The default output of mA2+ and mA- is probe 2 current or choose the probe 1 current.( select from “9 work mode”-------“2 the output of mA 2”)
★ As the running mode of double material level, the output of mA 1+ and mA-is probe 1 current. The output of mA2+ and mA- is probe 2 current.

 

 

Hot Products

Product Description: The KQRS14 is a versatile tool designed for measuring angular rotation rates ...
Product Description: The KQRS14: A Compact, Solid-State Inertial Sensor The KQRS14 is an inertial ...
2020 hot sale 485 cod instrument for surface water Introduction The COD sensor is Kacise's new ...
Liquid industrial non non contact radar level transmitter We also produce 6G and Guided wave radar ...
High accuracy radar liquid level meter We also produce 6G and Guided wave radar level meter. ...
stable silo cement radar level gauge We also produce 6G and Guided wave radar level meter. ...