ASTM D1298 Density / Specific Gravity Testing Equipment With Hydrometer Method

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

 

ASTM D1298 Density / Specific Gravity Testing Equipment With Hydrometer Method

                                       

Introduction

This density meter is suitable to determine density of easy flowing liquid,and if working with suitable constant bath,it can also be used to measure viscous liquid and opaque liquid under condition of higher temperature than room temperature.

 

I.Main features

1.Use glass heating bath,easy to observe

2.Integrated structure is easy to operate

3.Insulated glass tank,inner tank is Φ300×300mm

4.Two samples can be analyzed simultaneously,which is convenient to do parallel test

5.Big power solid relay controls output,no voltage leakage

6.There is stirrer on electrical heating bath

7.Stainless steel heater

8.Temperature controller displays heating status

9.It’s made by cold-rolled sheet,surface treated by Electrostatic spraying.It’s corrosion resisting and easy to clean.

10.Safety device can prevent over-heating or low liquid level

11.Contact control box is very convention

12.Micro-computer controller,PID function,digitally display temperature(continuously display during test),accuracy 0.1℃,Pt100 temperature sensor.

 

II.Technical specifications

1Applicable standards

GB/T1884 ISO3675 ASTM D1298

2Working unit

double units

3

Refrigeration method

Air compressor

4

Temperature controlling method

Imported digital PID

5

Temperature controlling accuracy

±0.1℃

6

Working temperature

10~100℃

7Power supply

AC220V/50Hz

 

                                              

Hot Products

Please email to Sandy@yuyangtest.com if you need details. Solar Cell Spread of Flame & Burning Brand ...
ISO 8301, EN 12667 Thermal Conductivity Tester of Heat Flow Meter 0.1 ~ 8.0 m2K/W Description: It is ...
100~450℃ Melt Flow Index Tester MFR MVR Thermoplastics ISO 1133 ASTM D1238 Description: The melt ...
BS EN136-1998 Medical Surgical Mask Flame Retardant Tester (800 ± 50) ℃ Description: The Flammabilit...
100~450℃ Melt Flow Index Tester MFR MVR Thermoplastics ISO 1133 ASTM D1238 Similarities ISO 1133 and ...
100~450℃ Melt Flow Index Tester MFR MVR Thermoplastics ISO 1133 ASTM D1238 ISO 1133 Vs. ASTM D1238 ...