PMCC-I Automatic Oil Analysis Equipment Pensky Martens Apparatus Easy Operate

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

PMCC-I Automatic Pensky-Martens Closed-Cup Flash Point Test Equipment

 

Summary
PMCC-I Automatic Pensky-Martens Closed-Cup Flash Point Tester is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.

I. Main technical features
1. Light-touch colored LCD. English man-machine dialog interface. All parameters including preset flash temperature, sample number, atmospheric pressure and date can be set by prompt menu.
2. Simulation tracking of temperature rising curve with time. Prompt function. Test date and time can be modified.
3. 120 groups of data can be saved.
4. Automatically calculate the corrected flash point when the pressure differs from standard atmospheric pressure.
5. Differential detection. Automatic correct the system bias.
6. Automatically open cover, ignite, detect and print result.
7. Safe and easy to operate.


II.technical specifications

1Power supplyAC(220±10%)V, 50Hz.
2Flash point determinationRange: Ambient to 300℃.
Meet requirement of GB/T 261-2008
Meet requirement of GB/T 261-2008
Resulotion: 0.1℃
3Heating rateProcedure A: (5~6)℃/min
Procedure B: (1~1.5)℃/min
4Stirring rateProcedure A: (90~120)RPM,
Procedure B: (250±10)RPM
Automatic control and manually adjustable.
5Igniting mode
Igniting source: gas(or other civilian fuels)Electric ignition.
Gas flame diameter: 3.2mm~4.8mm
6Ambient temperature≤ 40℃
7Relative humidity≤ 80%
8Maximum power consumption500W
9Overall dimension410mm×360mm×310mm

 

 

 

 

 

 

 

 

 

 

 


 

 

 

 

 

 

III.Accessories

No.
Item
Unit
Qty
1
Oil Cup
Piece
1
2
Power supply wire (250V 6A) 
Piece
1
3
Printer paper
Roll
1
4
Burning torch
Piece
1

Hot Products

Please email to Sandy@yuyangtest.com if you need details. BS476 Part 6 Fire Propagation Index Test ...
Please email to Sandy@yuyangtest.com if you need details. ISO 5660 Cone Calorimeter Fire Testing ...
Please email to Sandy@yuyangtest.com if you need details. EN ISO 9239-1 Flooring Radiant Panel Test ...
Please email to Sandy@yuyangtest.com if you need details. EN 13823 SBI Single Burning Items Test ...
Please email to Sandy@yuyangtest.com if you need details. EN ISO1182 Non-Combustibility Test ...
ISO 6722-1 Lab Single Core Wire Fire Testing Equipment with 60V/600V Introductions: Single wire / ...