Home Companies Dongguan HOOHA Electrical Equipment Company Limited

NFPA 701:2004 Textile Flammability Testing ZY6278 White Curtain Combustion Tester

Dongguan HOOHA Electrical Equipment Company Limited
Active Member

Contact Us

[China] country

Address: ROOM 1205, 12/F, TAI SANG BANK BUILDING, 130-132 DES VOEUX ROAD,CENTRAL, HONG KONG

Contact name:Jack young

Inquir Now

Dongguan HOOHA Electrical Equipment Company Limited

NFPA 701:2004 Textile Flammability Testing ZY6278 White Curtain Combustion Tester

Country/Region china
City & Province hong kong hong kong
Categories Solar Chargers
InquireNow

Product Details

NFPA 701:2004 Textile Flammability Testing ZY6278 Curtain Combustion Tester

 

Scope of application:


Used for testing the flame retardant properties of hanging fabrics such as curtain and curtain. It can be used for single or multi-layer fabric, but not for fabric material that is important in grams of 700 g/m2 (21 OZ/yd2).

 

Meet the standard:


Comply with the American fire protection association (NFPA) NFPA 701:2004 Test Method 1

 

Main parameters:


1. Combustion chamber:

Specification: width 675mm, depth 500mm, 700mm.

Structure: using 12mm thick Marinite mineral plate (calcium silicate plate), external package 1.2 thick 304# stainless steel composition, in front of the open type test case, the test box inner surface must be a smooth black coating. Conformity (NFPA) NFPA 701:2004 Chapter 5 requirements

2. Burner: a laboratory Burner for the Meker Burner hammer, which can be used for 10,500 BUT/Hour. Compliance with (NFPA) NFPA 701:5.3.3 requirements of 2004;

3. Needle bar for sample installation: 9mm stainless steel strip, 190mm long, with diameter of 0.7mm and 11mm steel needle

Steel wire brush: made of bronze (NFPA) NFPA 701:5.9 requirements of 2004

5. Sample frame: equipped with 5 stainless steel sample clips

6. Equipped with stainless steel standard test sample clip 5

7. Equipped with standard burning line 1 volume

8. Control part: conforming to (NFPA) NFPA 701:5.6 requirements of 2004

Control part: adopt automatic method: such as trigger timing, automatic opening and cutting off gas source, etc.

Touch mode: use proximity switch to trigger timing start;

9. Air supply system: equipped with pressure-reducing valve. The solenoid valve is used to automatically open and cut off the gas source. Conformity (NFPA) NFPA 701:5.4 requirements of 2004

10. Timer: 0~99.99 seconds can be set arbitrarily, resolution: 0.01 second, accuracy: 0.1 second;

11. Flow meter: for the rotor flow meter, adjust the height of the flame.

Hot Products

ZY6235 Pavement Material Radiant Heat Flux Test Device With Powerful Exhaust System Scope of ...
wire and cable test machine QJ57 DC Kelvin Bridge wire and cable test machine Product description: ...
HH62112 Series Bridge Fixtures cable test machine Product description: Bridge fixture in line with ...
IEC 60335 Withstand Voltage Test Instrument IEC 60335 Product description: Withstand voltage test ...
GB/T3048.5-2007 ZC-90 Series Insulation Resistance Meter GB/T3048.5-2007 ZC-90 Series Insulation ...
GB / T2951.11-2008 HH31113 Intelligent Auto Profile Projector Intelligent Auto Profile Projector ...