IEC 60243-1 Dielectric Strength Of Solid Electrical Insulating Materials Test Equipment

 

Application:

Apply to continuous uniform boosting or step by step boosting way, step by step toward a sample breakdown, ac/dc voltage until the breakdown voltage measurement, calculation of the sample breakdown strength.

 

Specifications:

Breakdown voltage0~50kV
Booting speed100,200,500,1000,2000,5000(KV/S)
Booting speed controlElectrical automatic control
Voltage measurement accuracy≤ 2%
The leakage current selection1~100 mA
Methods of testDC & AC
Methods of bootingAutomatic program-controlled
Power Frequencysine wave 50Hz/60HZ
Supply powerAC220V 50/60Hz
DimensionL 1400* W 1040* H 1500 mm
Weight200kg
Transformer capacity10 KVA
AC 0~50 KV (continuously adjustable)

 

 

Note:
 
After each test is completed, the sample must be fully discharged in advance before taking out the sample. When discharging, the contact residence time at each discharge point exceeds 2 seconds.

 

Instructions:


Take out the discharge rod and straighten the telescopic rod, insert the other end of the ground clamp into the metal probe socket of the discharge rod, and then clamp the ground clamp to the ground terminal A or B of the instrument. Bend down, open the glass door of the test chamber, and use the metal probe to touch the output voltage equalizing ball of the high voltage transformer, the electrode on the sample and the high voltage end of the capacitor one by one. (If necessary, use a multimeter to test the voltage between the electrode and the human body in the AC voltage file (AC20V file) after the discharge is completed, which is less than 36v, indicating that the residual voltage has been discharged.)

 

Hot Products

UL790 Roof Covering Combustion Performance Fire Resistance Testing Machine Introduction: The ...
Insulator Resistance To Electrical Tracking And Erosion Testing Machine IEC60587 Meet the standards: ...
Insulator Resistance To Electrical Tracking And Erosion Testing Machine IEC60587 Standards: IEC60587...
ISO 1182 Fire Testing Equipment Non Combustibility Test Apparatus ASTME2652 Application: When a ...
Molten Metal Splash Resistance Materials Test Machine Introduction: Evaluate the material's ...
ISO 9151 HTI Heat Transmission BS EN 367 Product Description: Heat transfer index is calculated from ...