Respiratory Protective Devices Particle Filters Testing Instrument
BS EN143 2000 Laboratory Automated
Scope of application:
PFE tester is used to detect the filtration efficiency of
particulate matter such as daily masks and filters. Factory
direct sales, mask inhalation and exhalation filter or filtration
efficiency tester automated filter tester.
Standards:
NIOSH 42 CFR 84, EN 149
YY/T 2626-2019 respiratory protection products
Technical Parameters:
Flow range | (20 ~ 100) L / min, accuracy 2% |
Filtration efficiency | (0.001 ~ 99.999)% |
Resistance | 0 ~ 2000Pa, accuracy 2% |
Test area | 100cm² |
Aerosol concentration | (12 ~ 20) mg / m³ (salinity), (50 ~ 200) mg / m³ (oily) |
External dimensions | 950 × 600 × 600mm |
Weight | 100kg |
Gas source | flow 198L / min (0.6Mpa) at 550kPa |
Aerosol | Sodium chloride (optional DOP, DEHS, paraffin oil, corn oil) |
Test temperature | (25 ± 5) ℃ |
Operation method:
1. The continuous and stable aerosol particles are produced by
using a cold generated aerosol generator, which is convenient for
filling solution.
2. High precision PM2.5 sensor * 2 imported from USA was used to
measure aerosol concentration.
3. The whole process is designed to prevent the leakage of
particles to protect the safety of laboratory personnel.
4. 2 sets of aerosol generator: salt particle aerosol generator and
oily particle aerosol generator (select salt particles or select at
the same time).
5. Electrostatic charge neutralization device is equipped with
aerosol.
6. Pneumatic fixture is equipped with protection device, which is
safe and convenient to use.
7. Equipped with glass rotor flowmeter, vacuum pump, laser dust
particle counter.
8. Control system: PLC and touch screen control.
9. It can automatically calculate assist and filter efficiency,
save, output, query and print test data.
10. Touch screen control, simple and intuitive operation.
![](http://img.everychina.com/nimg/2a/8d/311477f2c3da3273cc95b7da551b.jpg)
NACL