Vicat Softening Point Temperature Testing Equipment Microcontroller for Polymer Materials

Country/Region china
City & Province dongguan guangdong
Categories Valves
InquireNow

Product Details

Microcontroller Thermal Deformation, Vicat Softening Point Temperature Testing Equipment for Polymer Materials

 

Scope of application:

Mainly used for thermal deformation of polymer materials (such as plastics, rubber, nylon, electrical insulation materials, etc.) and determination of Vicat softening point temperature. Applicable to universities, research institutes and product quality supervision and inspection units.

 

Compliance with the standard:

in line with GB/T 8802-2001, ISO 2570 hard polyethylene (PVC), GB/T 1633, GB/T 1634, ISO 75-1987 (E), ISO 306-1987 (E) and other standards.

Standards compliant:

GB/T 1633-2000 (idt ISO 306:1994) Determination of Vicat Softening Temperature (VST)

GB/T 1634.1-2004 (idt ISO75-2:2003) Determination of plastic deformation temperature (general test method)

GB/T 1634.2-2004 Plastics Determination of Deflection Temperature at Loading (Plastics, Hard Rubber and Long Fiber Reinforced Composites)

GB/T 1634.3-2004 Plastics Determination of Deflection Temperature at Loading (High Strength Thermosetting Laminate)

GB/T 8802-2001 (eqv ISO 2507:1995) Determination of Vicat softening temperature of thermoplastic pipes and fittings

 

Parameters:

Test range: room temperature ~ 300 °C;

Number of sample holders: 2, 3, 6;

Heater power: 4KW;

Vicat variability: 1mm.

Deformation resolution error: 0.005mm

Heating rate: A = 5 °C / 6min B = 12 °C / 6min;

Maximum temperature measurement error: ±0.5°C

Maximum temperature control error: ±12°C/6 minutes (thermal deformation test) ±5°C/6 minutes (Vicat test)

1# weight (ie load rod, standard indenter, sensor probe, tray, screw): 68g ±1g

Heating medium: Silicone oil (200 cSt or less, flash point above 300°C)

Cooling method: natural cooling or water cooling (C type machine)

Dimensions: 520×420×1100mm;

Main power supply: 220V+10%, 15A, 50HZ;

Thermal deformation, Vicat softening point temperature tester Chinese version of the operating system test application software

Hot Products

EN137 Fire Testing Equipment , Mask Flame Resistance Flammability Test Chamber EN137 Mask Flame ...
PLC Touch Screen Control Thermal Insulation Rock Wool Thermal Load Testing Equipment Application: ...
IS0 3873 Safety Helmet Fire Resistance Testing Machine , Helmet Flammability Test Chamber Meet the ...
Steel Structure Fireproof Coating Sample Test Furnace / Construction Materials Flammability Testing ...
NBS Plastic Fire Resistance Smoke Density Testing Chamber for ISO 5659-2 Standard Product Descriptio...
DIN7520 Automotive Interior Material Combustion Fire Resistance Testing Equipment Standard: Conforms ...