Vertical PHYM 150 Gallon Mild Steel Foam Bladder Tank System For Fire Fighting

Vertical 150 Gallon Foam Bladder Tank System For Fire Fighting

 

 

INTRODUCTION

Foam bladder tank is the key unit in foam extinguishing system. Foam bladder tank system provides foam solution for all kinds of foam discharge devices such as foam chamber, foam generator, foam branch pipe, foam sprinkler, etc. It aims at fire of class A and class B, especially for fire of class B. The foam bladder tank mainly applied in occasions such as places where inflammable liquid was produced, stored and transported. It is especially suitable to put out fire caused by inflammable liquid tank or large scale of spill fire.

 

PRINCIPLE

Foam bladder tank consisty of bladder tank, rubber bladder, foam proportioner, pressure gauge, control valves and pipes. A pump is needed to supply pressurized water. When pressurized water flow though proportioner, a small part of water (3%-6%) flow into tank from branch pipe to press the bladder to swap out equal foam concentrate and then mix with another part of water (97%-93%) to form foam solution in proportioner and provide to foam generator.

 

PARAMETERS

Working Pressure Range (MPa)0.6~1.2 (87~174 PSI)
Pressure Drop (MPa)≤0.2
Test Pressure (MPa)1.6
Tank Capacity (L)200~15000 (52~3963 Gallon)
Size of Proportioner (mm)DN80~DN250 (3"~10")
Flow Capacity(L/S)4~360 (63~1513 GPM)
Mixing Ratio (L/S)3% OR 6%

 

 

INSTALLATION

Device should be installed at places with shelter to avoid sun and rain. Ambient temperature should be within 40°C and leave enough space for operation. Device should be installed at concrete floor and fastened with anchor nuts.

Do the hydraulic test after installing. Open the tank vent valve first then fill water into bladder from concentrate draining pipe. Then close tank vent valve when bladder is full of water. Pressurize the system and keeping for 10 minutes when pressure gets test pressure, tank should have no leakage. Close water inlet valve and open water drainage valve and concentrate drainage valve to drain water away in tank and bladder. (We will do this test when products leave the factory)

 

 

 

 

 

 

1. Tank

2. Pressure Gauge

3. Water Inlet

4.Feed Inlet

5. Foam Outlet

6. Safety Valve

7. Tank Vent

8. Inspection Hole

9. Lifting Lug

10. Check Valve

11. Bladder Vent

12. Liquid Indicator

13. Bracket

14. Water Drainage

15. Foam Drainage

16. Proportioner

 

CAPACITY LITERSD
mm
L
mm
L1
mm
B
mm
B1
mm
H
mm
H1
mm
WEIGHT
(KG)
5008008106001000115017001200280
1000100010108001200135021001200350
15001200121010001400155021001200450
20001400141012001600175020501200550
30001400141012001600175024501200800
400016001600140018001950280012001050
500017001680150019002050300012001200
600018001760160020002150330012001400
800019001820170021002250380012001600
900020001920180022002350390012001900
1000022002120200024002550430012002200

Hot Products

Dry Powder Fire Suppression Systems Description and Principle The dry powder system rely on the ...
Fire Suppression Systems With Dry Powder , Fire Protection For Fire Fighting Description and ...
Dry Powder Fire Suppression Systems Description The dry powder system rely on the dynamic of ...
Dry Powder Fire Extinguishing Equipment 3000kg Dry Powder Fire Suppression Systems For Oil and ...
Dry Powder System Fire Extinguisher Gas Dry Powder Fire Suppression Systems 500kg 750kg 1000kg ...
1.0~1.2mm stainless steel fire hose cabinet for school hotel library using fire cabinet Introduction ...