1U 144 Cores Pre-terminated High Density MPO/MTP-LC Rack Mounted
Patch Panel
1.Product Description:
With the rapid development of data centers, super-large data
centers are planning to move from 100G to 400G. Mass deployment is
expected
to begin in 2019, increasing the reliability, manageability, and
compatibility requirements of data center cabling.
The reliability, manageability, and compatibility of cabling are
the most basic guarantees for speed improvements in data centers.
Geehe's HD-Fiber Optic Patch Panels are applied to MDA, IDA, or HDA areas of the data center. It is
designed for the management of MPO-LC Module and MPO Adapter
Panels and can be installed in a 19-inch rack and cabinet.
2.Features & Benefits:
- Sliding-type with Ergonomic design, convenient installation, and
maintenance
- Radius protected patch cord routing, easy for the cable management
and improved density
- The module box can be installed or removed from the front or rear
of the distribution frame
- 3* 16F module or 3*6-port adapter panels in each layer
- Designed to fit fiber optic wall mount and rack mount enclosures
- Patch panel design guide rail and easy pull out
- Available with OM4 or single-mode fiber arrays and adapters
3.Application:
- Data communication applications
- Data Centre infrastructure
- Storage Area Network - Fibre Channel
- Emerging 40 and 100Gbps Protocols compatible
4. Specification and Technology Parameter
Product | HD 1U Fiber patch panel |
Material | Cold-rolled steel sheet |
Cassettes | 4 pcs MPO Cassettes |
Max Capacity | 144 Cores |
Adapter | LC adapter, MPO adapters |
Colors | Black |
patch cord Qty | 1x24fo, 2x12Fo ,1x12 Fo |
Fiber Mode | G657A1, OM1,Om2,Om3,Om4 |
Panel Height | 1U |
5. Frequent Q&A For HD Fiber Patch Panel :
Q: What are the benefits of using a patch panel?
A: Patch panels will allow testing routing and maintenance of
network cables connected to your network. With a patch panel this
is quickly done just by making changes to cables on the patch panel
itself. Patch panels also allow for easier cable management and
identification of cable routing.
Q: What is a rack unit?
A: A rack unit U or RU is a unit of measure that describes the
height of equipment designed to mount in a rack. A rack unit is
1.75 inches. Typically one rack unit will take three vertical screw
holes on each side of a standard rack.
Q: Can I use any fiber patch cable in my network with my enclosure?
A:If your fiber enclosure is loaded you must have cables that are
compatible with the included adapters. For unloaded enclosures you
must select adapter panels which correspond to your fiber connector
type or use a splice tray for single- and mass-fusing.
Q: What are the differences between the fiber connectors?
ST- Uses a push and turn to lock system
SC- Has a molded plug casing with push and pull locking system
6.More Black Box HD Fiber Patch Panels Options: