SELF SUPPORTING AERIAL APPLICATIONS(SM 12/24 FIBERS)

 

Cable Cross-section

 

 

 

Cable Identification

 Each cable ends are sealed with heat shrinkable end caps to prevent water ingress.

 Fiber color code

No.123456
ColorBlueOrangeGreenBrownGrayWhite
No.789101112
ColorRedBlackYellowVioletPinkAqua

 Loose tube (LT) & filler rod (FR) color code

Fiber

count

Element no.
123456789101112
12LTLTFRFRFR       
24LTLTLTLTFR       

 

* “LT” means “Loose Tube”;

** “FR” means “Filler Rod”.

Cable Assembly & Dimensions

Fiber

count

Max. fiber count

per tube

Total unit

count

(LT + FR)

Loose tube

Messenger

wire

Cable sheath thickness

(nominal*)

Connector (Height*Width)

Overall diameter

(nominal**)

Weight

(approx.)

mmmmmmmmmmkg/km
1262LT+3FR1.91.6*72.02.5*2.010.5*19.4235
2464LT+1FR1.91.6*72.02.5*2.010.5*19.4235

* The nominal sheath thickness may have a tolerance with ±0.2mm.

* * The nominal overall diameter may have a tolerance with ±0.5mm.

 Performance of Cabled Optical Fiber

The performance of cabled optical fiber (ITU-T Rec. G.652D)

ItemSpecification
Fiber typeSingle mode
Fiber materialDoped silica

Attenuation coefficient

@ 1310 nm

@ 1550 nm

 

£ 0.36 dB/km

£ 0.22 dB/km

Point discontinuity£ 0.05 dB
Cable cut-off wavelength£ 1260 nm
Zero-dispersion wavelength1302 ~ 1322nm
Zero-dispersion slope£ 0.092 ps/(nm2.km)

Chromatic dispersion

@ 1288 ~ 1339 nm

@ 1271 ~ 1360 nm

@ 1550 nm

@ 1625 nm

 

£3.5 ps/(nm. km)

£5.3 ps/(nm. km)

£18 ps/(nm. km)

£22 ps/(nm. km)

Mode field diameter @ 1310 nm9.2±0.4 um
Core / Clad concentricity error£ 0.5 um
Cladding diameter125.0 ± 0.7um
Cladding non-circularity£1.0%
Primary coating diameter245 ± 5 um
Proof test level

100 kpsi (=0.69 Gpa), 1%

 

Performance of Optical Fiber Cable

5.1 Cable bending radius: 15 x cable diameter (static)

25 x cable diameter (dynamic)

5.2 Application temperature range

Operating temperature range: -40oC to +70oC
Storage / Transport temperature range: -40oC to +70oC
Installation temperature range: -10oC to +50oC

 

 

 

 

 

5.3 Mechanical & environmental performance test

S/NItemTest MethodAcceptance Condition
1

Tensile Strength

IEC 794-1-E1

- Load: 5.0KN

- Length of cable under load: 50 m

-Load time: 1min

- Loss change £ 0.1 dB @1550 nm

- No fiber break and no sheath damage.

2

Crush Test

IEC 794-1-E3

- Load: 1.0KN/100mm

- Load time: ≥1min.

- Loss change £ 0.1 dB @1550 nm

- No fiber break and no sheath damage.

3

Impact Resistance

IEC 794-1-E4

- Points of impact: 3

-Times of per point: 1

- Impact energy: 4.5 NŸm

- Radius of hammer head: 12.5mm

- Loss change £ 0.1 dB @1550 nm

- No fiber break and no sheath damage.

4

Repeated Bending

IEC 794-1-E6

- Bending radius: 20 x cable diameter

- Load: 150 N

- Flexing rate: 3 sec/cycle

- No. of cycle: 30

- Loss change £ 0.1 dB @1550 nm

- No fiber break and no sheath damage.

5

Torsion

IEC 794-1-E7

- Length: 1 m

- Load: 150 N

- Twist rate: 1 min/cycle

- Twist angle: ±90°

- No. of cycle: 10

- Loss change £ 0.1 dB @1550 nm

- No fiber break and no sheath damage.

6

Water Penetration Test

IEC 794-1-F5B

- Height of water: 1 m

- Sample length: 3 m

- Test time: 24 hours

- No water shall have leaked from the opposite end of cable.
7

Temperature Cycling Test

IEC 794-1-F1

- Temperature step:

+20oC→-40oC→+70oC →+20oC

- Time per each step: 12 hrs

- Number of cycle: 2

- Loss change £ 0.05 dB/km@1550 nm

- No fiber break and no sheath damage.

8

Compound Flow

IEC 794-1-E14

- Sample length: 30 cm

- Temp: 70°C ± 2°C

- Time: 24 hours

- No compound flow

 

Packing

6.1 Each single cable length been wound on an iron stand-wooden composite or pure wooden drum.

6.2 Standard drum length is 4000m with ±2%.

6.3 Covered by plastic buffer sheet.

6.4 Sealed by strong wooden battens.

6.5 At least 1m of cable inner end should be reserved for testing.

 

Note: The value “D” contain the seal dimension

Cable TypeDrum lengthDdBb
GYFC8Smmmmmmmmm
12/24F400014407601100980

 

 

 

Hot Products

DA-ODN-OP-YH Fiber Optic Distribution Box Dawnergy’s DA-ODN-OP-YH fiber optic distribution box is a ...
DA-FDB-24D-A-8 Fiber Optic Distribution Box Dawnergy’s fiber optic distribution boxes are widely ...
DA-FDB-16Z-PA-3 Fiber Optic Distribution Box Dawnergy’s fiber optic distribution boxes are widely ...
DA-FDB-48B-PA-10 Fiber Optic Distribution Box Dawnergy’s fiber optic distribution boxes are widely ...
DA-FDB-16Z-PA-3 Fiber Optic Distribution Box Dawnergy’s fiber optic distribution boxes are widely ...
DA-FDB-16C-WPC-19 Fiber Optic Distribution Box FTTH Pre-terminated Application Refer to above FTTH ...