Home Companies Hongkong Yaning Purification industrial Co.,Limited

Class 100 405W 1800m3/h Cleaning Laminar Flow Hood

Hongkong Yaning Purification industrial Co.,Limited

Contact Us

[China] country

Trade Verify

Address: No. 6, Sanhuan Rd, Chiling Industrial Zone , Houjie Town, Dongguan City, Guangdong Province, China

Contact name:Viola

Inquir Now

Hongkong Yaning Purification industrial Co.,Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Class 100 405W 1800m3/h Cleaning Laminar Flow Hood

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

Class 100 cleaning laminar flow hood with a light switch and a socket.

 

 

Cleaning  laminar flow hood usage :

1. When used in a Class 100 laimar flow hood, the ultraviolet germicidal lamp should be turned on 50 minutes in advance to deal with the microorganisms accumulated in the clean workbench. After 30 minutes, the germicidal lamp should be turned off and the blower should be started.
2. Do not store unnecessary items on the surface of the 100-level clean laimar flow hood to keep the net airflow in the work area undisturbed.
3. Newly installed or unused class 100 clean benches must be carefully cleaned with ultra-clean vacuum cleaners or non-fiber-producing tools for the clean benches and surrounding environment before being used, and then UV sterilization Carry out sterilization treatment.

4. Always pay attention to the indication of the differential pressure gauge above the working area. When the pointer enters the red zone from green, it indicates that the dust holding capacity of the high-efficiency air filter is becoming saturated. The fan voltage should be increased, and the wind speed in the working area must be measured with an anemometer. When the average wind speed is less than 0.3m/s, then The filter has expired and should be replaced.
5. Unnecessary items should not be stored in the clean workbench to keep the net air flow pattern undisturbed.

6. After installing the Class 100 clean bench, please check again whether all parts are normal or not. Before starting the work, please clean it thoroughly with alcohol. Check whether the power plug is reliably inserted into the power socket. Turn on the power switch, the controller power indicator light is on, press the increase/decrease button of the fan to start the operation of the fan, please do not put items in the suction port or above the suction port, so as not to cause damage to the product due to the reduced air intake performance.
When the resistance of the high-efficiency filter is greater than 200Pa or less than 0.3m/sec, the high-efficiency filter should be replaced.
7. Always pay attention to the indication of the differential pressure gauge above the working area. When the pointer enters the red zone from green, it indicates that the dust holding capacity of the high-efficiency air filter is becoming saturated. The fan voltage should be increased, and the wind speed in the work area must be measured with an anemometer. When the average wind speed is <0.
At 3m/s, the filter has failed and should be replaced.
8. Regularly use a hot bulb electric anemometer to measure the average wind speed in the work area. If it is found that the technical indicators are not met, the voltage of the fan unit motor can be adjusted to make the class 100 clean workbench in a better working condition.
9. The HT533A air volume controller is used to explain that the HT533A air volume controller is one of the HT533 series of air volume controllers. It is a special modulator designed and developed to adjust the air volume for the clean bench.
There are eight lines of electrical appliances, adjustable voltage memory. Touch keyboard operation and other functions.
10. The class 100 clean bench can be operated by one person or by two persons.

 

Cleaning laminar flow hood parameter

 

SPECIFICATIONS FOR LAMINAR FLOW CABINET
Itemsingle horizontal typedouble horizontal typedouble vertical type
Size960*750*1580 mm1200*820*15801500*700*1800
Class levelclass 100 @0.3 um(FED 209)
Rated air volume1200m3/h1800m3/h2300m3/h
Air velocity0.3-0.6 m/s
Filter Efficiency99.999%@ 0.3um H13,H14
Power280W405W490W
Noise65dB
Power Supply220V/50Hz

Customized design is welcome.

 

Production detail photos

 

Packaging
Size1600*800*1950mm
Weight200kg

 

 

 

Packaging Details

The normal package is wooden box(Size: L*W*H). If export to european countries,the wooden box will be fumigated.If container is too tigher,we will use pe film for packing or pack it according to customers special request.

 

Shipping
itemby air or by sea
time7-30 days

 

 

 

Shipping Details

1. Samples be shipped by DHL/FedEx/UPS and so on.
2. Mass production be shipping by Air or Sea.

 

Hot Products

Lacquering plate air locked room automatic air shower with Face recognition system Entrance guard ...
Cargo Air Shower tunnel Cargo Pass through box with PVC fast rolling door 1.Product description 1...
Full 304 SUS Air shower room for clean room accessories decontamination air shower 1. Air shower ...
Clean room accessories clean room air shower with Automatic sliding door 1.Air shower description ...
Air shower clean room air shower cabin with powder coating steel frame Product Description Details ...
Air Shower For Clean Room With Face Recognition System And Temperature Detection System Facial ...