Length 19 Mm Dental Endodontic Instruments SX NITI CM Mire Taper File

 

CM Gold Engine, SX NITI CM-Mire taper File,root canal instruments, ISO, used for dental
 
Specifications:

 

TaperSX.05
TorqueSX3.0 N/CM
Rotary Speed RangeSX300-375 RMP
SizeSX#19
ISO ColorSXYellow
Using TimesSX15-18 times
Cross SectionTriangle

 
Description:


1. The Heat Activation is almost identical to the Gold at the Top of Operation.

 

2. Heat Activation is also made with special materials and processing technology.

 

3. Especially in terms of fracture resistance, it has an advanced bending function and temperature dependent change, it is now the international leader level.


Structure:


1. Shaping Files(SX,S1,S2):Using SX to make the formation of crown and short root canal, preparation the upper 1/3 root canal with S1, S2 for middle 1/3 root canal preparation.

Operation Sequence:


1. Establishing linear channel , cleaning the canal with sodium hypochlorite


2. Detect the root canal Using #10, #15 SSK file


3. Makes the formation of crown with SX and create the canal path (cleaning with Sodium Hypochlorite )

 
 
Warning:


1.Only skilled dentists are allowed to use.
2. Be sure to sterilize this product for each use.
3. Do not use this product except for the dental service and treatment. Use it in accordance with the intended use.
 
Precautions for use:


1. To prevent infection, sterilize the product by autoclave and make sure
sterilization is completed before using.
2. Choose the most appropriate type for each case and follow the general
method.
3. Before using, make sure the instruments outside of dental cavity that
there are no deformations, scratches and cracks.
4. If the head of product is thin, long or large, there are possibilities for
breaking or twisting. Because of this, be sure to avoid using
unreasonable angle and excessive pressure.
5. Wear safety glasses to protect your eyes from damage. Also, wear a
dust protective mask to prevent inhaling dust.
6. Wear rubber dam etc. to avoid accidental ingestion and falling.
7. Do not use this instrument for any purposes except for listed
applications above.
8. Only for use by dentists.
9. After using, follow an appropriate treatment as medical waste.
10. Dispose the product if damaged or contaminated.
11. After using, wash it with medical cleaning agent and brush, then
wash away foreign substances like adherent body fluids and body
tissues.
12. Set the product to a stand when cleaned by ultrasonic cleaner to avoid
working part deterioration.
13. Use this product with great care to avoid puncturing fingers because
of its possession of sharp-edged part.
 
 
Storages and duration of use:


1. Avoid storing at high temperature, humidity and direct sunlight.
Keep liquids away. Store it at room temperature.
2. Do not damage or make a pinhole to packaging materials.
3. Do not keep under germicidal lamp to avoid deterioration.
 
Maintenances and inspections:


1. Sterilize this product by autoclave under established method and
term for each use.
Method of sterilization:
Put this product in a sterilization pack or (or foil) and place it on a
sterilization tray, or files stand for autoclave sterilization with
reference to the following terms.
Terms for sterilization:
term(1) temperature: 121degrees Celsius time: 20 minutes or more
term(2) temperature: 126degrees Celsius time: 15 minutes or more
2. Do not use high pressure steam sterilizer which heats more than 135 degrees Celsius including drying process.

 
Packages:


1. Minimum packaging unit: 6 pcs. /package (SX)
 
 
Applications:

 

Dental Root Canal TreatmentHospital , Clinic , lab...

 
Competitive Advantage:


1, Eliminating Root Canal perforation
2, Improving 300%-500% Fracture Resistance
3, Optimizing recovery of Unique NITI CM-Wire Material
 

Hot Products

Size S1 Niti Files Endodontics Voilet Root Canal Instruments With ISO Approved NITI Super Files Gold ...
NITI Super Files Gold Material Endo Hand Files For The Formation Of 1/3 Root Canal Tip They are ...
Super Files Gold Hand use NITI Material Assorted Size ISo Color Dental Material with Silicon Stopper ...
NITI Super Files Gold Hand File like Protaper Gold with M-wire Material Size F4 ISO Yellow Root ...
Blue M Wire Endodontic Files Size F3 With Advanced Nano Gold Plating Technology NITI Super Files ...
NITI M Wire Material Endo Hand Files Gold With Good Fracture Resistance NITI Super Files Gold Hand ...