Sinuo Testing Equipment Co. , Limited |
Verified Suppliers
|
Electromagnetic Shielding Room
Complied Standards & Clauses
EN50147 “High-performance shielding room shielding effectiveness of
the measurement method”
CISPR17 “passive radio interference filter and suppression element
suppression characteristics of the measurement method”
CISPR25 “Radio disturbance characteristics of vehicles, boats and internal combustion engines Limits and methods of
measurement for the protection of vehicular receivers”
ISO11452-4 “Road vehicles with narrowband emitted electromagnetic energy electronic interference components test method
BCI large current injection method”
GB/T 50719-2011 “Electromagnetic shielding room engineering
specifications”
GB/T 12190 “Electromagnetic shielding room shielding effectiveness
of the measurement method”
Equipment Overview
Samples and Resrictions: The electromagnetic shielding room is used to isolate the electromagnetic environment indoors and outdoors to ensure the normal operation of indoor electronic and electrical equipment. Mainly used for conducted emission test, conducted immunity test, EMI discontinuous interference test, etc.
Application: Electrical appliances and electronic devices, including in-car electronic systems, generate a certain amount of electromagnetic waves at work that may interfere with surrounding equipment or be received by specialized equipment.
The electromagnetic shielding room is used to isolate the
electromagnetic environment indoors and outdoors, which can prevent
external electromagnetic interference from entering the room to
affect the test, and can limit the electromagnetic leakage of
indoor high-power high-frequency equipment to prevent the influence
to people and equipment around. It is the ideal venue for EMC
testing.
Test Principle: Electromagnetic shielding room is mainly used for automotive
electronic conduction emission (CE) test, transient conducted
immunity test, bulk current injection method (BCI) test, stripline
method test, etc.
Technical Parameters
Typical Application | Conducted Emission Test (CE) | |
Discontinuous Interference Test (CLICK) | ||
Conducted Immunity Test (CS) | ||
RF Disturbance Power Test (RFP) | ||
Tricyclic Antenna Radiation Test (MFI) | ||
Inductive Current Density Test(EMF) | ||
Harmonic currents, voltage fluctuations and flicker (Harmonic & Flicker) | ||
Shielding effectiveness SE (According to EN50147-1) | ||
Field Source | Frequency (MHz) | Shielding Effectiveness (dB) |
Magnetic Field | 0.014 | ≧70 |
Magnetic Field / Electric Field | 0.1 | ≧90 |
Magnetic Field / Electric Field | 1 | ≧100 |
Electric Field | 100 | ≧110 |
Electric Field | 450 | ≧110 |
Electric Field | 950 | ≧100 |
Electric Field | 3000 | ≧100 |
Electric Field | 18000 | ≧100 |