Home Companies Sinuo Testing Equipment Co. , Limited

IEC60068-2-2 Vibration Shaker with Climatic Chamber Testing Equipment -40℃~+180℃

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC60068-2-2 Vibration Shaker with Climatic Chamber Testing Equipment -40℃~+180℃

Country/Region china
City & Province guangzhou guangdong
Categories Used Measuring & Analysing Instruments
InquireNow

Product Details

 

 

IEC60068-2-2 Vibration Shaker with Climatic Chamber Testing Equipment -40℃~+180℃

 

Complied Standards & Clauses


 

IEC 60068-2-1:2007 Environmental testing for electric and electric products-Part 2-1: Tests-Test A: Cold, IDT

IEC60068-2-2: 2007 Environmental Testing-Part 2-1:Tests- Test B-Dry heat, IDT

IEC60068-2-30:2005 Environmental Testing-Part 2-30:Tests-Test Db.: Damp heat, cyclic (12h+12h cycle),IDT

IEC60068-2-78:2001 Environmental Testing-Part 2-78:Tests-Test Cab: Damp heat, steady

state, IDT

 

Product Overview


 

It is used to provide temperature and humidity change environment for aerospace, aviation, aviation petroleum, chemicals, electronics, communications and other scientific research and production units. At the same time, the electrical vibration stress can be applied to the test sample according to the specified period in the test chamber for test the reliability and adaptively of the sample. The product introduction is divided into two parts, the first part is Electromagnetic Vibration Testing Machine SN553-EV322HG120VT120.GP.VCS-2,and the second part is Temperature, Humidity and Vibration Three Comprehensive Test Chamber SN888-7200B-CT.

 

Technical Parameters


 

Input channel
Number of input channels2 simultaneous input channels
Input signal typeVoltage/charge
Input resistance>110 kΩ
Maximum voltage input range±10V
Maximum charge input range±10000PC
SNR>100dB
Filter160dB/octave analog filter
Input interfaceThree optional inputs: voltage, ICP and charge
Maximum input士10VPEAK

Analog/digital converter

(ADC)

24-bit resolution,

dynamic range: 114dB, maximum sampling frequency 192kHz

Circuit characteristicsThe input interface has a built-in ICP constant current source and charge amplifier, with two ranges of 10V/1V and optional AC/DC coupling, and an analog anti-aliasing filter.
Output channel
Number of output channels2 output channels
Output signal typeVoltage signal
Output impedance<30Ω
Maximum voltage output range±10V
Maximum output current100mA
Amplitude accuracy2mV
Harmonic distortion<-95dBfs
Filter160dB/octave analog filter
Channel matchingAmplitude 0.04dB, phase ±0.5

Digital/analog converter

(DAC)

24-bit resolution, dynamic range: 120dB, maximum sampling frequency 192kHz
Circuit characteristicsAnalog anti-aliasing filter; output protection circuit
Test typeRandom vibration control/sinusoidal control/typical shock control
 

 

Digital vibration controller function description

Random control

According to the user-defined power spectrum diagram (made by the target spectrum editor), random control adopts the method of transfer function equalization. Continuously output Gaussian random signals to quickly implement real-time and accurate multi-channel closed-loop control. Built-in adaptive control algorithms react quickly to system nonlinearities, resonant frequency, and load changes.

Frequency range: 0~4800Hz, extendable to 18750Hz

Resolution: 100, 200, 400, 800, 1600, 3200 spectral lines

Control power range: >90dB

Control strategy: single channel control, weighted average, maximum value, minimum value.

Sine control

Sine provides analog-quality sine and sine sweep signals with control over the amplitude of the sine waveform. The dwell magnitude, dwell frequency can be set, and the dwell duration can be determined by setting the time or the number of cycles of the sinusoidal signal.

Frequency range: 1Hz~5000Hz, expandable to 10000Hz

Closed loop time: 5 mS

Harmonic distortion: <-100dB

Frequency sweep mode: linear frequency sweep 0~6000 Hz/min | Logarithmic sweep 0~100 Oct/min

Sweep direction: up, down

Sweep duration: can be set as the number of sweeps or test times.

Classical Shock

Adopt transfer function equalization method, support half sine wave, bell wave, rectangular wave, trapezoidal wave, front peak sawtooth wave, back peak sawtooth wave, triangular wave. Users can also input pulse peak value according to their needs.

Pulse duration from 0.5 to 3,000mS

Maximum analysis bandwidth 18750Hz

Frame size: up to 16384

Meet the standards: MIL-STD-810 (US military standard), ISO standard, user-defined interrupt control limit.

 

Details


 

Hot Products

IEC 62196-1 Electric Vehicle Charging Interface Mechanical Load Test Device Complied Standards & ...
IEC60068-2-2 Programmable Constant Temperature and Humidity Test Chamber 1000L Complied Standards & ...
IEC60068-2-78 -70℃ Cold Balanced Constant Temperature and Humidity Test Chamber 1000L Complied ...
IEC 60068-2-6 Linear Temperature Humidity and Vibration Three Comprehensive Test Chamber 5400L ...
IEC60529 IP5/6X Walk-In & Ground Embedded Sand And Dust Test Chamber Complied Standards & Clauses ...
IEC60529 IP5/6X EV Charge Station Walk-In Sand & Dust Test Chamber Complied Standards & Clauses ...