Home Companies Sinuo Testing Equipment Co. , Limited

IEC60068-2-1 High And Low Temperature Test Environmental Chamber SN889-240L

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC60068-2-1 High And Low Temperature Test Environmental Chamber SN889-240L

Country/Region china
City & Province guangzhou guangdong
Categories Electrical Instruments
InquireNow

Product Details

 

 

IEC60068-2-1 High and Low Temperature Test Environmental Chamber SN889-240L

 

Complied Standards & Clauses


 

IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

 

Product Overview


 

1. Energy saving: The technology is based on the PWM solenoid valve customized by Sporlan Company in the United States. This technology realizes the regulation of the pipeline flow through the frequent actions of the solenoid valve. The standard solenoid valve cannot adapt to it, and it will cause fatigue damage in a short time. Currently, this technology is supported. The main performance valve is only produced by Sporlan Company in the United States. The following picture shows the difference between the solenoid valves.

 

2. Performance: The equipment conforms to the latest standards, the equipment is integral, beautiful and easy to transport;The main parts of the equipment are selected from well-known brands at home and abroad. The fully enclosed and imported French "" compressor with higher precision and the Hangzhou "Yuanfang" variable frequency power supply with better stability make the precision control more accurate during the operation of the equipment. Noise Lower, more stable performance and longer service life;

 

3.Device control: The device can be connected to multiple devices, controlled by mobile phone APP, and controlled by advanced PLC, which is more intelligent and more convenient to operate. The true color touch screen displays various test data (temperature, time, test curve), which is easier to operate. observation records;

 

4.Measurement and control system: real-time and dynamic display of test process and test curve, data processing through modular software, data reanalysis and editing of curve amplification, output of test reports and curve patterns in different formats, and support for networked data transmission.

 

5. Professional, safe and user-friendly design: emergency stop control switch, in case of emergency, can lock equipment reliably; effectively protect equipment; multiple protection of software and hardware to ensure the safety of equipment and personnel.

 

Technical Parameters


 

Main technical parameter

 

No.ProjectContent
AProduct modelSN889-240L
BProduct brandSINUO
CStudio sizeD600 x W800 X H500 mm (without motor)
Outer DimensionsCabinet part: about 14500 D × 1050W × 1570H mm
DTemperature range-40℃~+250℃(range adjustable)
Temperature uniformity≤2.0℃ (stable state)
Heating rate≥3.0℃/min (no load)
Cooling rate1.0℃/min (no load)
Temperature fluctuation±0.5℃ (stable state)
Temperature deviation±2.0℃
EMotor noise≤85dB
WeightAbout 680kg
FNoteThe above performance indicators are the values measured at room temperature +25°C without sample.
 
MaterialInner box materialSUS304# stainless steel plate
Outer box materialCold-rolled steel plate, pickling and phosphating high-grade powder paint
Insulation materialRigid polyurethane foam + ultra-fine glass fiber
StructureAir duct partsCentrifugal fan; the air outlet can adjust the air volume, height and return air volume
Door(Single) Open hinged door, equipped with observation window, lighting, window frame/door frame anti-condensation electric heating device, door size: (approx.) 0.8*0.5M
Test windowThere is a conductive film explosion-proof tempered glass observation window on the door (with anti-condensation function) 380W×580H (mm)
FanLong axis centrifugal fan
Sample holderTwo built-in stainless steel adjustable movable trays
ImpellerImported stainless steel impeller from Taiwan
HeaterNickel-chromium alloy electric heater
Refrigeration CompressorsImported Tecumseh compressor
EvaporatorFinned evaporator
Cooling methodMechanical compressor cascade
Cooling methodAir cooling
Temperature control instrumentColor touch screen imported from South Korea
Lead holeφ50mm, 1 piece (located on the left side of the box)
 Sample holder2 stainless steel sample racks, height adjustable.
 
Heating and cooling systems and how they work
 
ProjectPrinciple description
Heating systemStainless steel tube sleeve type anti-dry heating tube with built-in nickel-chromium alloy heating wire
U-shaped fin type stainless steel high-speed heating electric heater for heating
Completely independent system, does not affect the control line
Refrigeration systemCooling methodAir-cooled
Refrigeration compressorAdopt imported Tecumseh compressor, use environmentally friendly refrigerant
Refrigerant copper tubeInternal spiral K-TYPE refrigerant copper tube
CondenserCorrugated fin type air-cooled condenser
EvaporatorSlope type FIN—TUBE evaporator
Freezing elementOriginal imported solenoid valve, drying filter, etc.
FeaturesThe whole system pipelines are tested for leak detection by ventilating and pressurizing 22kg.
Heating and cooling systems are completely independent
Equipped with the company's professional technical characteristics, it can prevent the high temperature and high-pressure airflow from returning to the cooling machine and damage the system.
All refrigeration system action programs are completely controlled by microcomputer controller
 

Adjustment system

 

ProjectSpecifications
Adjustment method

Forced circulation ventilation, balanced temperature regulation. The control system controls the output of the heater according to the temperature point set by the system through the result of PID automatic calculation output, and finally achieves a dynamic balance.

 

 

 

Circulation deviceThe built-in air-conditioning room, circulating air duct and long axial flow fan improve the air flow and heating capacity by improving the agitation airflow of the air, and greatly improve the temperature uniformity of the test chamber.

 

Control system:

 

ProjectIllustrate
Controller7-inch PLC LCD touch programmable controller
Touch high-definition screenThe fixed conditions and program conditions can be set arbitrarily, the Chinese screen can be set, and the curing test name and serial number can be set.
Settable time range0—999H59min.

Programmable mode

 

At the same time, 120 groups of programs with different conditions can be set. In any group of programs, the work can be divided into 1200 segments, and the number of segments can be arbitrarily intercepted to execute the cycle, or the periodic cycle of any segment or group can be performed.
In each group of programs, up to 1200 different temperature and time sections can be set (each section can be set up to 999h59min). 120 groups of programs can be connected in series at will, and the maximum number of sections can be cycled up to 999 times.
SafetyWith a power-off memory device, the remaining programs can continue to be executed when the power is restored, and the machine can be reserved to execute the start-up and machine running time.
ControlRising and cooling can be used for slope control and curve control, and has the function of self-correcting temperature and humidity reference points. It has the function of PID automatic calculation, which can reduce the convenience brought by manual setting.
Communication functionU disk interface, RS-232 interface, mis operation hardware lock, random computer communication software
Set upTouch setting, direct display of position, all conditions are completely automatically locked by microcomputer
AlarmIf there is an error in the setting or operation, a warning signal will be provided
OutputThe controller has a recording signal port output, which can be connected to a temperature and humidity recorder and output a recording curve
InterfaceWith standard RS-232 communication interface, long transmission distance, can be connected to PC for control and recording.
 

Safety protection device

 

Cooling System

Compressor overheating protection

Compressor overcurrent protection

Compressor high and low pressure protection

Compressor oil pressure protection

Liquid temperature over-temperature protection

Ultra-high pressure relief protection

Air-cooled: the condensing fan is overheated

Test box

Adjustable over temperature protection

Air conditioning channel extreme over temperature protection

Fan motor overheating protection

Other

Overload and short circuit protection

Refrigeration system failure alarm protection caused by multiple openings of the box

Other configuration
Power cableAC380V power supply: five-core (three-phase four-wire + protective ground wire) cable (about 4 meters long)
Main power switchChint Circuit Breaker
Installation site

1. The ground is flat and well ventilated

2. No strong vibration around the device

3. There is no strong electromagnetic field around the device

4. There is no flammable, explosive, corrosive substances and dust around the equipment

5. Appropriate space for use and maintenance should be reserved around the equipment, as shown in the following figure:

 

A: ≥40cm, B: ≥150cm, C: ≥100cm, D: ≥60cm, E: ≥40cm

Environmental conditions

1. Temperature: 5℃~35℃

2. Relative humidity: ≤85%

3. Air pressure: 86kPa~106kPa

Power supply conditions

AC380V power supply requirements:

1. Three-phase four-wire + protective ground wire

2. Voltage range: AC (380±38) V

3. Frequency fluctuation range: (50±0.5) Hz

4. The grounding resistance of the protective ground wire is less than 4Ω

5. The user is required to configure an air or power switch of the corresponding capacity for the equipment at the installation site, and this switch must be used independently for the equipment

Power supply

Imax≤20A

Pmax≤6.5KW

Maximum currentOpening the door of the test box during the test will cause the temperature and humidity in the box to fluctuate; if the door is opened multiple times or for a long time or the test sample emits moisture during the test, it may cause the heat exchanger of the refrigeration system to freeze instead of working properly.

 

 

Details


 

  

Hot Products

IEC 62196-1 Electric Vehicle Charging Interface Mechanical Load Test Device Complied Standards & ...
IEC 62196 Electric Vehicle Connector And Plug Universal Material Tensile Machine Complied Standards ...
IEC62196-1 EV Mechanical Load Flexing Test Equipment of Vehicle Plugs Socket-outlets Complied ...
IEC 62752 EV Chargers Electromagnetic Vibration Shock Testing Machine Complied Standards & Clauses ...
IEC60068-2-78 Constant Temperature Humidity Testing Chamber 1500L Complied Standards & Clauses ...
IEC60068-2-2 Programmable Constant Temperature and Humidity Test Chamber 1000L Complied Standards & ...