4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker

Country/Region china
City & Province chengdu
Categories Battery Chargers
InquireNow

Product Details

 

40A 4 Pole 30mA Type B 10KA Residual Current RCD Circuit Breaker

 

What are RCDs?

Residual Current Devices (RCDs) are safety switching devices. They are designed to provide safety for three types of protection; 

  1. Fault Protection. Any tripping current dependent on the resistance of the earth path.
  2. Additional Protection. RCDs not exceeding 30 mA tripping current.
  3. Fire Protection. A tripping current not exceeding 300 mA.

 

Specification

 

Type(wave form of the earth leakage sensed)B Type RCCB
Rated current In
63A
Poles4P
Rated voltage Ue
2P 240V~,4P 415V~
Insulation voltage Ui500V
Rated frequency50/60Hz
Rated residual operation current(I n)30mA
Rated residual making and breaking capacity (I m)
500A(In≤40A), 10In(In>40A)
Short-circuit current Inc= I c10000A
SCPD fuse10000
Break time under I n≤0.1s
Rated impulse withstand voltage(1.5/50) Uimp4000V
Dielectric test voltage at ind.Freq. for 1min2.5kV
Electrical life2,000 Cycles
Mechanical life4,000 Cycles

 

Installation

 

Contact position indicatorYes
Protection degreeIP20
Ambient temperature(with daily average≤35°C)-5°C~+40°C
Storage temperature-25°C~+70°C
Terminal connection typeCable/Pin-type busbar/U-type busbar
Terminal size top/bottom for cable35mm2 18-3AWG
Terminal size top/bottom for busbar35mm2 18-3AWG
Tightening torque2.5Nm 22In-lbs
MountingOn DIN rail EN60715(35mm) by means of fast clip device
Connection
Power supply in both directions

 

Tripping Current Range

 

Tripping
Lagging Angle
I△n>0.01A
I△n≤0.01A
Current
0.35I△n≤I△≤1.4I△n
0.35I△n≤I△≤2I△n
Range
90°
0.25I△n≤I△≤1.4I△n
0.25I△n≤I△≤2I△n
 
135°
0.11I△n≤I△≤1.4I△n
0.11I△n≤I△≤2I△n

 

 
Detectable wave formPulsating direct current sensitiveSurge current proof
B class
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents,alternating residual sinusoidal currents up to 1000Hz,pulsating direct residual currents and for smooth direct residual currents,whether applied suddenly or increasing slowly.
RCD.jpg
They react to AC and pulsating DC fault current which reach 0 or almost 0 within one time period of the mains frequency.
rccb.jpg
RCCB’s surge capacity.
Not tripping at standardized 8/20 υs surge-current waves acc.to VDE 0432 Part 2 with surge current values of up to 250A.

 

Circuit Diagram

What are the effects of DC residual fault current on RCDs?
it might be worth thinking about some older models of earth fault loop impedance testers, which could cause the RCD to operate unintentionally. To prevent this, some types of earth fault loop impedance testers imposed a DC current on the AC test current. This DC current saturated the magnetic core of the RCD preventing it from tripping under the test condition.

 

Where equipment produces an element of residual DC, for example, variable-speed drives is connected to the electrical installation, the DC component can saturate the magnetic core and effectively blind or locks the RCD. This is known as ‘blinding’ and could either prevent the RCD from operating or reduce the sensitivity resulting in a dangerous situation.

 

Application

 

Construction sites

Agricultural and horticultural premises

Conducting locations with restricted movement

Caravan and camping parks

Exhibition shows and stands

Outdoor lighting

Marinas

Medical locations

Solar Photovoltaic system power supplies

Mobile or transportable units

Electric vehicle charging installations

Temporary installations for structures, amusement devices and booths at fairgrounds, amusement parks and circuses, and

Floor and ceiling heating systems.

 

 

Certification:TUV

 

Hot Products

32A 7.4kW type 1 charging cable electric car mode 3 cable type 1 to type 2 Product Features The ...
32A 480V 22kW AC EV Type 2 to Type 2 EV Charging Cables Product Features Product Name tpye2 to type2 ...
Rated Current:16A/32A Rated Voltage:250V/ 480V AC Casing Protection Rating:IP55 Casing Material...
22kW 3 Phase 480V EV Charger Type 2 EV Charging Cable for Electric Car Charging Leads The ANS ANSAG...
TUV/CE listed 11k Type 2 to Type 2 ev charging cable for Zoe Specification: Input volatge/output ...
EV Charging Plug Pins Terminal Contact Hard Sliving Plating EV pins AC IEC terminal Item dimension...