KYN61-40.5 High voltage AC metal enclosed switchgear customized by professional switchgear manufacturer
Product description
KYN61-40.5 armored removable AC metal-enclosed switchgear
(hereinafter referred to as switchgear) three-phase AC 50Hz, rated
voltage 40.5kV indoor complete power distribution device. As power
plants, substations, and industrial and mining enterprises to
receive and distribute electric energy, it can control, protect and
monitor circuits, and can also be used in places with frequent
operations.
This switchgear complies with GB3906-2006 "3~35kV AC Metal-enclosed
Switchgear", GB/T11022-1999 "High Voltage Switchgear and Control
Equipment Standard Common Technical Requirements" and DL/T 404-2007
"3.6kV~40.5kV AC Metal-enclosed switchgear and control equipment"
and other standards.
Model and its meaning
①Metal armored switchgear
②Removable
③Indoor
④Design serial number
⑤Rated voltage (kV)
⑥Type of circuit breaker: Z-vacuum; SF6-sulfur hexafluoride
⑦Rated current
⑧Rated short-circuit breaking current (kA)
Scope of application
•Ambient temperature: upper limit +40°C, and the average value
measured within 24h does not exceed 35°C, lower limit -10°C;
•Altitude: altitude does not exceed 1000m;
•Relative humidity: the daily average value does not exceed 95%,
and the monthly average value does not exceed 90%;
•Earthquake intensity: no more than 8 degrees;
• Water vapor pressure: the daily average value does not exceed
2.2kPa, and the monthly average value does not exceed 1.8kPa;
Surrounding environment: a place where there is no fire,
explosion hazard, serious pollution, chemical corrosion and severe
vibration.
Technical Parameters
Name | Unit | parameter |
Rated voltage | kV | 40.5 |
Rated current | A | 1250 1600 2000 |
Rated frequency | Hz | 50 |
Rated short-time withstand current | kA | 20 25 31.5 |
Rated peak withstand current | kA | 50 63 80 |
Rated power frequency withstand voltage | kV | 95/lmin |
Rated lightning impulse withstand voltage | kV | 185 |
Rated short-circuit duration | s | 4 |
Protection level | IP3X |
Installation dimension drawing
A. Busbar room
B. Handcart room
C. Cable room
D. Relay instrument room
1. Lifting ring
2. Main bus
3. Cover ring for small busbar compartment
4. Instrument room door
5. Branch bus
6. Bus bushing
7. Hornworm head box
8. Analog bus coil
9. Nameplate
10. Lighting
11. Handcart room door
12. Current transformer
13, hairpin chain
14. Insulator
15. Zinc oxide arrester
16. Insulating partition
17. Grounding switch
18. Valve assembly
19. Vacuum circuit breaker handcart
20. Small busbar terminal room
Need to know when ordering
Users need to provide the following information if ordering
• The main circuit plan number, purpose, single-line system
diagram, arrangement diagram and power distribution room layout
diagram, etc.;
• Auxiliary circuit wiring schematic diagram and terminal
arrangement diagram;
• The model, specification and quantity of electrical components in
the switchgear;
• Requirements for control, measurement and protection functions of
switchgear, as well as requirements for other locking and automatic
devices;
• If a bus bridge connection is required between switchgears or
incoming cabinets, the rated current carrying capacity of the bus
bridge, the span of the bus bridge, the height from the ground and
other specific requirements data should be provided; • When
accessories and spare parts are needed, the types and quantities
should be provided;
• The switchgear is used in special environmental conditions and
should be specified when ordering.