Home Companies Guangdong Bell Experiment Equipment Co., Ltd

High Current Short Circuit Graphite Resistance Battery Test Chambers 10000A 100mΩ

Guangdong Bell Experiment Equipment Co., Ltd
Active Member

Contact Us

[China] country

Address: No.11 Wusong 1st Street, Dongcheng District, Dongguan 523117, Guangdong, China

Contact name:Choi

Inquir Now

Guangdong Bell Experiment Equipment Co., Ltd

High Current Short Circuit Graphite Resistance Battery Test Chambers 10000A 100mΩ

Country/Region china
City & Province dongguan guangdong
Categories Polishers
InquireNow

Product Details

Custom High Current Short Circuit Graphite Resistance Cabinet

 

Design Overview
High-current short-circuit resistance cabinet line design shall be able to withstand the impact of high current colleagues to ensure the stability of the resistance value: contact copper plate and wire must be selected under the internal resistance value of all-copper material; resistance using graphite material resistance, resistance stability, resistance does not change with the temperature, resistance of very good linearity, you can adjust the resistance accuracy to 0.1mΩ.

 

 

 

Main technical parameters

 

 

Model

BE-XL-5000ADZBE-XL-10000ADZ

 

Maximum load short-circuit current

 

5000A10000A

 

Resistance

 

1~100mΩ adjustable (can choose to adjust the resistance value without pole or adjust in steps)
For example:
1mΩ (maximum passing current 5000A)
5mΩ (maximum passing current 5000A)
10mΩ (maximum through current 2000A)
20mΩ (maximum through current 1000A)
80mΩ(maximum passing current 500A)
100mΩ(maximum passing current 500A)

 

1~100mΩ adjustable (can choose to adjust the resistance value without pole or adjust in steps)
For example:
1mΩ (maximum passing current 10000A)
5mΩ (maximum passing current 10000A)
10mΩ (maximum through current 10000A)
20mΩ (maximum through current 5000A)
80mΩ(maximum passing current 1000A)
100mΩ(maximum passing current 500A)

 

Heat dissipation control system

2 axial flow fans installed on the top with intelligent temperature control control system.

 

 

Equipment features

 

Graphite resistance

 

  Graphite resistor performance.
  1. Thermal stability: for the use of the product rapid heat and cold conditions, special design to ensure the          reliability of product quality.
  2. Graphite has a high degree of electrical conductivity, can withstand more than 3000 ℃ high               temperature,melting point 3800 ℃, boiling point 4250 ℃, with plasticity, chemical stability, insoluble in acid and alkali.
 

  3. Corrosion resistance: uniform and fine matrix design delays the erosion degree of the product.
 

  4. Impact resistance: the thermal shock strength that the product can withstand is extremely high, so any          process treatment can be carried out with confidence.
 

  5. Acid resistance: The addition of special materials significantly improves the quality of the product, which        is excellent in terms of acid resistance index and greatly extends the service life of the product.
 

  6. Control of metal contamination: The strict control of material composition ensures that the product does        not contaminate metal when dissolving.
 

  7. Quality stability: High-pressure formation of the production technology process and quality assurance            system to more fully ensure the stability of quality.

 

 

 

  Design of graphite resistors
 

  1. Connection: the use of series connection, connected through the copper plate
 

  2. Graphite resistor: using round graphite resistor rod. Convenient for precision processing and assembly          as well as easy adjustment of linear resistance value.
 

  3. Structure: bracket support, multi-layer graphite assembly superimposed, side access to the wire.
 

  4. The top of the structure is installed with high temperature resistant axial flow exhaust fan heat dissipation control system. When the graphite resistor is instantly overloaded to generate high temperature, the heat dissipation control system will automatically start the axial fan for air absorption and heat dissipation. And put out a red light alarm. Protect the graphite resistor and also remind the operator to pay attention to the safety of the experiment.
 

  5. Heat dissipation partition network: steel wire sealing plate is installed on the left and right sides of the            bracket to improve heat dissipation performance and high safety protection.

 

 

 

Hot Products

Lab Tabletop 50L Small Volume Temperature Humidity Environmental Test Chamber Application Benchtop ...
Constant Temperature Humidity Chamber,3 Layer Environmental Test Chambers Manufacturers Advantage ...
Benchtop Temperature and Humidity Environmental Test Chambers Application Benchtop Temperature and ...
Benchtop Temperature And Humidity Environmental Test chamber Application Benchtop Temperature and ...
Temperature Humidity Test Chamber ≤ 2.0 ℃ Temperature Deviation Temperature Humidity Test Chamber ...
Three Box Temperature Humidity Test Chamber for Temperature / Humidity Test Features With high ...