Product Details

Thermal Abuse Test Chamber for Battery Module According to UL 1642 IEC62133 IEC62619

 

 

What is Thermal Abuse Test Chamber ?

 

Thermal abuse test chamber protect for short circuit caused by incorrect operation of the operator and battery electrode, battery positive and negative connection, etc

 

 

What are the standards for thermal abuse test chambers?

  • IEC 62133
  • IEC 62619
  • UL 1642

 

What are the relevant standard requirements ?

Single storage cell Safety Test

Heating test steps:

  • Charge the battery according to the standard 6.1.3
  • Place it into the chamber

–For lithium storage battery, the oven temperature is raised at a rate of 5℃/min to the temperature of 130℃±2℃, remain this temperature for 30min, then stop heating.

–For metal cyanide nickel battery, the oven temperature is raised at a rate of 5℃/min to a temperature of 85℃±2℃, remain this temperature for 2h, then stop heating.

  • Observe for 1h

 

Storage Battery Module Safety Test

  • Charge the battery module according to the standard 6.1.4
  • Place it into the chamber

-For lithium storage battery, the oven temperature is raised at a rate of 5℃/min to a temperature of 130℃±2℃, remain this temperature for 30min, then stop heating.

–For metal cyanide nickel battery, the oven temperature is raised at a rate of 5℃/min to a temperature of 85℃±2℃, remain this temperature for 2h, then stop heating.

  • Observe for 1h

 

Thermal Abuse Test Chamber Technical Parameters

 

Model

 

BE-101-1000A

Temp. Range

 

Ambient – 200℃ (Controllable)

Control Accuracy

 

±0.5℃

Temp. Uniformity

 

±2.0℃( No load)

Temp. Rising Speed

 

RT – 150℃ (≧5℃/min, liner with load 40kg module)

Temp. overshoot

 

≦2.0℃

Control Display

Method

 

PLC Touch screen + remote control, networking,
Cell phone APP alarm device, with USB interface, R485 interface can be connected to computer control.

Testing Room Dimension

 

W1000 X D1000 X H1000 mm

External Chamber Dimension

 

W1400 X D1300 X H1840 mm

Inner chamber Material

 

SUS304 Stainless Steel (Mirror finished)

External chamber Material

 

SECC Steel Plate, Powder Painted

Basement

 

With universal wheel

Observation Window

 

390 X 360mm (20mm Tempered Explosion Proof Glass)

Power Source

 

380V 50HZ

Heating Power

 

About 12 KW

Safety Protection Device

 

over-voltage, over-temperature, over-current protection.

 

protection for short circuits caused by incorrect operation of the operator and battery electrode, battery positive and negative connection, etc.

Safety Device

 

Smoke exhaust system, explosion-proof pressure relief port, tri-color light alarm.

 

Hot Products

Lab Tabletop 50L Small Volume Temperature Humidity Environmental Test Chamber Application Benchtop ...
Constant Temperature Humidity Chamber,3 Layer Environmental Test Chambers Manufacturers Advantage ...
Benchtop Temperature and Humidity Environmental Test Chambers Application Benchtop Temperature and ...
Benchtop Temperature And Humidity Environmental Test chamber Application Benchtop Temperature and ...
Temperature Humidity Test Chamber ≤ 2.0 ℃ Temperature Deviation Temperature Humidity Test Chamber ...
Three Box Temperature Humidity Test Chamber for Temperature / Humidity Test Features With high ...