Home Companies Godson Technology Co., Ltd

Twin Spots Emergency LED Downlight White 2.5W 130mm CRI70 5700k

Godson Technology Co., Ltd

Contact Us

[China] country

Trade Verify

Address: Unit 103B (Main Building), Building 4, No. 29 North Pier Road, Huang Pu Village, Haizhu District, Guangzhou, Guangdong, China ,510330

Contact name:Paul Huang

Inquir Now

Godson Technology Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Twin Spots Emergency LED Downlight White 2.5W 130mm CRI70 5700k

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details


LED Twin Spots Emergency LED Downlight White 2.5W 130mm TGSS3


Technical Specifications

 

Mains Supply220-240VAC ,50/60Hz
Power2.5W
Duration Time3 Hours
Recharge Period16 Hours
Battery Size & TypeLiFePO4 3.2V1.5Ah
LED Power1.6/2.0/2.5W (emergency)
CCT5700k
CRI70
Luminous Flux350 lm (emergency)
Protection ClassClass
Operating Temperature0-40

 

 

Features

 

-Plastic head and steel base
-Wall mounting, IP20
-LiFePO4 battery, replaceable
-Non-maintained operation
-Intelligent charge and discharge
-3 hours emergency duration
-Self test is customizable
- With 1.2meter flex and plug

 

 

Materials
 
-Base: steel
-Lamp head: PC+ABS
-Diffuser: PC



Standard Compliance

 

-AS2293.3
-AS 60598.2.22
-AS/NZS 60598.1
-AS CISPR 15
-IEC62133
-AS61347-2-7
 

Dimensions

 

 

LED Emergency Twin Spot Light:
 

An LED Emergency Twin Spot Light is a type of emergency lighting fixture that utilizes LED technology. It is designed to provide illumination during power outages or emergencies. Here are some key features and characteristics of LED Emergency Twin Spot Lights:

1.LED Technology: LED (Light Emitting Diode) lights are energy-efficient and have a longer lifespan compared to traditional lighting sources. They provide bright and reliable illumination.

2.Twin Spot Design: The "twin spot" refers to the presence of two separate light heads or lamps in the fixture. This design allows for broader coverage and flexibility in directing the light.

3.Battery Backup: LED Emergency Twin Spot Lights typically have built-in rechargeable batteries that automatically activate when the main power supply fails. These batteries provide power to the LEDs, ensuring continuous illumination during emergencies.

4.Adjustable Heads: The light heads of twin spot lights are often adjustable, allowing users to pivot or rotate them to direct the light where it is needed most.

5.Mounting Options: These lights can be mounted on walls, ceilings, or other suitable surfaces, depending on the specific model and installation requirements.

6.Duration of Operation: The duration of operation during an emergency can vary depending on the battery capacity and power consumption of the LED lights. It is important to consider the expected runtime and ensure that it meets the required standards and regulations.



What Are Maintained Emergency Lights Types?

 

Maintained lights are illuminated all the time (24/7) for safety. This means that they switch to a battery-powered emergency output. Even if the power fails, the light will remain on.

This safety light is most commonly an LED, and it should illuminate an exit path and should be easily seen should there be a fire to provide the occupant's safety.

An emergency lighting system in continuous use is called a maintained system. These lighting systems typically remain illuminated 24/7, and each light has dual purposes - one as a regular emergency lamp and another as an emergency light. Maintained lighting systems are often used as escape route lighting and found in buildings such as hospitals or police stations.

 

 

What Are Non-Maintained Emergency Lights?

 

Non-maintained lights usually are not illuminated and will only turn on (illuminate) when the power fails. - The batteries are constantly being charged while ever there is power to the fitting. Power can be cut to a building in the event of a fire. Fire safety security alarm systems can control signs and luminaires. These fire safety systems require appropriate training, building signs and appropriate lighting.

 

 

Why Godson?

-- Professional And Stay Focused

More than twenty years’ experience in battery industry; Keep focusing on emergency lighting battery, e-bike battery and power tool battery.

-- Great Reliability

Expected life of our Ni-Cd battery pack is more than 5 years; Expected life of our LiFePO4 battery pack is more than 10 years; Our batteries comply with standards of ICEL 1010, IEC 60598, IEC 61951, IEC 61960, IEC 62133 and UN38.3.

-- Super High Cost-Effective

Price of our products is much more competitive comparing with our competitors, but with the same or even better performance.

-- Strict Control In Production Process

ISO9001/2008 standards are strictly implemented in every process of our production.

-- Quick Response and Fast Delivery

Every inquiry would be replied within 24 hours, each order would be delivered within 30 days.

-- Flexibility in orders
Small orders acceptable as well.

Hot Products

Stick Type 3.6 Volt D4000mah Batteries Ni Cd Exit Light Batteries Product parameters: Pos. Product ...
Emergency Lighting Batteries | Ni-CD D4000mAh 3.6V | Good safety Product parameters: Pos. Product ...
HS Code 8507300090 NiCD SC1200mAh 3.6V Battery Emergency Lighting Product parameters: Pos. Product ...
Led Emergency Light LiFePO4 6600mah Battery 6.4V Blue PVC IFR26650 LiFePO4 Rechargeable Battery 6.4V ...
14500 Lithium Iron Phosphate Battery Rechargeable 3.2V 1200MAh LiFePO4 Rechargeable Battery 3.2V ...
UPS Emergency Lighting IFR 18650 Cell LiFePO4 Battery 12.8 V 1600mAh Description of LiFePO4 Battery ...