SHANGHAI SUNNY ELEVATOR CO.,LTD |
Verified Suppliers
|
|
50HZ Or 60HZ 5A Power Supply Cabinet / Elevator Control Cabinet
Elevator Parts AC380V Three Phase 50HZ 60HZ 5A Elevator Control Cabinet
Introduction
This device is designed to improve the safety performance of the
elevator. The device makes use of the original control and
frequency conversion system of the elevator and the driving system
not independent of the original elevator control system, so it has
the characteristics of simple installation and wiring, convenient
debugging, and high cost performance. In the process of using the
elevator, once the power supply system is cut off, it will cause
physical and psychological injury to the passengers trapped in the
elevator. When the above situation occurs, the device will
automatically put into operation within the set time, so that the
elevator car will slowly run to the nearest station level, open the
door and release the passengers in the light load direction.
Main technical parameters
1. Input parameters:
Input voltage: | Three _phase AC380V+ 10% (at AC380V) Three-phase AC220V+10% (at AC220V) |
Frequency: | 50HZ or 60HZ |
Battery pack: | 2x 12V/5AH(7AH/12AH) or 3x 12V/5AH (7AH ) |
2. Output parameters:
Inverter output voltage: | Two-phase AC380V+10% (at AC380V) Two-phase AC220V+10% (at AC220V) |
Frequency: | 50HZ or 60HZ |
Maximum output current: | 5A |
3. Applicable environment:
Ambient temperature: | -30℃ - ~ 60℃ |
Humidity: | 30%~ 75% (Non-condensing) |
Installation size
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.