SHANGHAI SUNNY ELEVATOR CO.,LTD |
Verified Suppliers
|
|
Elevator Electrical Parts Photoelectric Switch With IP54 Protection
Technical Data | |
Output Mode | PNP output |
Detection Distance (groove width) | 23mm |
Standard Testing Objects | Opaque more than ∅ 1.5mm |
Light Source (Wavelength) | IR LED(850-940nm) |
Supply Voltage | DC12~24V ±10 % Ripple (p-p) < 10 % |
Current Consumption | < 40mA |
Control Output | Load supply voltage is lower than DC26.4V, load current is lower than 100mA (the remaining voltage is lower than 1V) NPN Open type output Light in: ON/Shading: ON Switch mode |
Protective Circuit | Power reverse connection protection |
Response Time | Action < 1ms Reset < 1ms |
Working Ambient Temperature | Receives illumination: Filament Lamp ≤ 3,000lx; Sunlight ≤ 10,000lx |
Ambient Temperature | Work:-25~+55 C, Storage: -40~+70 C (non-freezing, non-condensing) |
Ambient Humidity | Work: 35~85 % RH, Storage: 35~95 % RH (non-condensing) |
Dielectric Resistance | 20M Ω (DC500V Megger) between whole conductor and the shell |
Voltage Withstand | AC1,000V 50/60Hz 1min between whole conductor and the shell |
Vibration(Endurance) | 10~55Hz Amplitude fluctuation 1.5mm 2hs X, Y, Z each direction |
Impact(Endurance) | 500m/s2 X, Y, Z each direction three times |
IP Code | IEC Standard IP54 |
Connection Type | Wire Leads Type (Standard Lead Length 2m/500mm) |
Indicator Lamp | Action Indicator (Red) |
Gross Weight | ≈ 100g |
Wiring Mode | Red: Power Supply +/- Black: Power Supply -/+ Yellow: Output OUT |
BE-GS3B4 Products Detail
Technical Data | |
Output Mode | PNP output |
Detection Distance (groove width) | 30mm |
Standard Testing Objects | Opaque more than ∅ 1.5mm |
Light Source (Wavelength) | IR LED(850-940nm) |
Supply Voltage | DC12~24V ±10 % Ripple (p-p) < 10 % |
Current Consumption | < 40mA |
Control Output | Load supply voltage is lower than DC26.4V, load current is lower than 100mA (the remaining voltage is lower than 1V) NPN Open type output Light in: ON/Shading: ON Switch mode |
Protective Circuit | Power reverse connection protection |
Response Time | Action < 1ms Reset < 1ms |
Working Ambient Temperature | Receives illumination: Filament Lamp ≤ 3,000lx; Sunlight ≤ 10,000lx |
Ambient Temperature | Work:-25~+55 C, Storage: -40~+70 C (non-freezing, non-condensing) |
Ambient Humidity | Work: 35~85 % RH, Storage: 35~95 % RH (non-condensing) |
Dielectric Resistance | 20M Ω (DC500V Megger) between whole conductor and the shell |
Voltage Withstand | AC1,000V 50/60Hz 1min between whole conductor and the shell |
Vibration(Endurance) | 10~55Hz Amplitude fluctuation 1.5mm 2hs X, Y, Z each direction |
Impact(Endurance) | 500m/s2 X, Y, Z each direction three times |
IP Code | IEC Standard IP54 |
Connection Type | Wire Leads Type (Standard Lead Length 2m/500mm) |
Indicator Lamp | Action Indicator (Red) |
Gross Weight | ≈ 200g |
Wiring Mode | Red: Power Supply +/- Black: Power Supply -/+ Yellow: Output OUT |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements.
Configuration is not only for wire rope and rated load, but also
considered the size of the traction, as a result, the tensile
strength of wire rope is greater than the weight of the lift. The
safety factor is equipped with more than four wire rope. So it
won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily
proportional to the operation complexity. Therefore, escalators
designed by us apply an integrated structure, so that the equipment
is more precise and more efficient and allows easier and more
convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.