Elevator Electrical Parts Photoelectric Switch With IP54 Protection

 

 
BE-G3SE4 Products Detail
Technical Data
Output ModePNP output
Detection Distance (groove width)23mm
Standard Testing ObjectsOpaque more than ∅ 1.5mm
Light Source (Wavelength)IR LED(850-940nm)
Supply VoltageDC12~24V ±10 % Ripple (p-p) < 10 %
Current Consumption< 40mA
Control OutputLoad supply voltage is lower than DC26.4V, load current is lower than 100mA (the remaining voltage is lower than 1V) NPN Open type output Light in: ON/Shading: ON Switch mode
Protective CircuitPower reverse connection protection
Response TimeAction < 1ms Reset < 1ms
Working Ambient TemperatureReceives illumination: Filament Lamp ≤ 3,000lx; Sunlight ≤ 10,000lx
Ambient TemperatureWork:-25~+55 C, Storage: -40~+70 C (non-freezing, non-condensing)
Ambient HumidityWork: 35~85 % RH, Storage: 35~95 % RH (non-condensing)
Dielectric Resistance20M Ω (DC500V Megger) between whole conductor and the shell
Voltage WithstandAC1,000V 50/60Hz 1min between whole conductor and the shell
Vibration(Endurance)10~55Hz Amplitude fluctuation 1.5mm 2hs X, Y, Z each direction
Impact(Endurance)500m/s2 X, Y, Z each direction three times
IP CodeIEC Standard IP54
Connection TypeWire Leads Type (Standard Lead Length 2m/500mm)
Indicator LampAction Indicator (Red)
Gross Weight≈ 100g
Wiring ModeRed: Power Supply +/- Black: Power Supply -/+ Yellow: Output OUT

BE-GS3B4 Products Detail 

Technical Data
Output ModePNP output
Detection Distance (groove width)30mm
Standard Testing ObjectsOpaque more than ∅ 1.5mm
Light Source (Wavelength)IR LED(850-940nm)
Supply VoltageDC12~24V ±10 % Ripple (p-p) < 10 %
Current Consumption< 40mA
Control OutputLoad supply voltage is lower than DC26.4V, load current is lower than 100mA (the remaining voltage is lower than 1V) NPN Open type output Light in: ON/Shading: ON Switch mode
Protective CircuitPower reverse connection protection
Response TimeAction < 1ms Reset < 1ms
Working Ambient TemperatureReceives illumination: Filament Lamp ≤ 3,000lx; Sunlight ≤ 10,000lx
Ambient TemperatureWork:-25~+55 C, Storage: -40~+70 C (non-freezing, non-condensing)
Ambient HumidityWork: 35~85 % RH, Storage: 35~95 % RH (non-condensing)
Dielectric Resistance20M Ω (DC500V Megger) between whole conductor and the shell
Voltage WithstandAC1,000V 50/60Hz 1min between whole conductor and the shell
Vibration(Endurance)10~55Hz Amplitude fluctuation 1.5mm 2hs X, Y, Z each direction
Impact(Endurance)500m/s2 X, Y, Z each direction three times
IP CodeIEC Standard IP54
Connection TypeWire Leads Type (Standard Lead Length 2m/500mm)
Indicator LampAction Indicator (Red)
Gross Weight≈ 200g
Wiring ModeRed: Power Supply +/- Black: Power Supply -/+ Yellow: Output OUT

 

 

FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.

Hot Products

DC110V Brake Voltage Gearless Traction Machine For Safe And Stable Elevator Operation Features ...
32 Poles Gearless Traction Machine For Stable Elevator Operation With DC110V Brake Voltage SSL ...
32 Poles Gearless Traction Machine With F Insulation Class For Safe Elevator Operation SSL 1800kg ...
Permanent Magnet Synchronous Gearless Traction Machine 220/380V Voltage Type:SN-MONA150A Voltage ...
0.25-2.0m/S High-Performance Gearless Traction Machine For Elevator Solutions Type:SN-MY05-E(Φ420...
IP41 Rated Gearless Traction Machine For Elevators With 0.4-1.0m/S Speed Voltage 220V/380V Roping 2...