Home Companies Delta Technology (Chongqing) Co., Ltd.

CCT Building Material Heat Release Rate HHR Testing ISO5660 ASTM E1354 Cone Calorimeter

Delta Technology (Chongqing) Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.85 Zhong Shan Yi Road, Yu Zhong District, Chongqing, China. 400010

Contact name:Tina Chen

Inquir Now

Delta Technology (Chongqing) Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

CCT Building Material Heat Release Rate HHR Testing ISO5660 ASTM E1354 Cone Calorimeter

Country/Region china
City & Province chongqing chongqing
InquireNow

Product Details

CCT Building Material Heat Release Rate HHR Testing ISO5660 ASTM E1354 Cone Calorimeter

 

Introduction:

  • The CCT Cone calorimeter is designed and manufactured according to international standards and mainly for building products and electric cable testing.
  • The analysis cabinet of our CCT ISO5660 Cone Calorimeter can be moved, it can be used for cone calorimeter test, and it can also be used in the large heat release rate test system such as Single Burning Item(SBI), cable burning test system, etc.


Parameters:

Measured properties:

  1. Heat release rate;
  2. Flue gas flow rate;
  3. C coefficient;
  4. Time to ignition;
  5. Extinction time;
  6. Total oxygen consumption;
  7. Smoke release rate;
  8. Mass loss rate;
  9. Effective heat of combustion;
  10. Rates of release of combustion gas (e.g. CO and CO2)

 

Application Field:

  1. Building products;
  2. Railway rolling-stock applications;
  3. Maritime applications;
  4. Electric cables;
  5. Etc;
No.Item NameCCT Building Material Heat Release Rate HHR Testing ISO5660 ASTM E1354 Cone Calorimeter
1Dimension1800mm (W) x 900mm x (H) x 2600mm (D)
2Weight350kg
3Power supply220V, 50Hz
4Ambient temperature10 ~ 35 Centigrade
5Working gasCompressed air
6Calibration gasCH4, N2, CO2/CO mixed gas

 

 

Application Field:

  1. Building products;
  2. Railway rolling-stock applications;
  3. Maritime applications;
  4. Electric cables;
  5. Etc;

 

Features:

  1. Integrated body and 19" analysis rack, 15" touch screen panel type PC for the whole control and automatic testing
  2. Conical Heater - is wound in the form of a truncated cone, rated 5000 W at 230 V with a heat output of 100 kW/m2.
  3. Facility for testing horizontally or vertically orientated specimens
  4. Temperature control by the use of a 3 type K thermocouples and a 3-term (PID) temperature controller.
  5. Auto Split Shutter automatically opened to transmit radiation to the sample, Automatic Spark Igniter to facilitate measurement of ignition time
  6. Specimen Holders - for specimens 100mm x 100mm up to 50mm thick, in the horizontal and vertical orientation.
  7. Load Cell - mass measurements are conducted via a strain gauge load cell with an accuracy of 0.1g. Fitted with a quick electronic tare facility and mechanical stops to avoid movement damage, give stable results and long life.
  8. Exhaust System - manufactured from stainless steel for long life. This comprises, hood, gas sampling ring probe, exhaust fan (with adjustable flow controls from 0-50g/s, at a resolution of at least 0.1g/s) and an orifice plate flow measurement (thermocouple and differential pressure transducer). Normal operation is at a nominal 24 l/s.
  9. ABB Gas feed unit, Model SCC-S, including 1 gas path, condensate monitor, pump and flow controller with needle valve Peltier cooler and condensate pump. SCC-S can remove water automatically.
  10. ABB EL3020-Uras26+ Magnos206, CO 0-1%, CO2 0-10%, automatic calibration of CO & CO2, does not require the use of mixture of CO&CO2 gas. O2 0-25%, Only once a month is used to calibrate the zero point with the nitrogen,
  11. Smoke Obscuration - measured with a laser system, using photodiodes, and a 0.5 mW Helium Neon laser, with main and reference (compensating) photo detectors. Supplied with alignment cradle and 0.3, 0.8 neutral density filters for calibration.
  12. Medtherm Heat Flux Meter - for setting the irradiance level at the surface of the specimens, the range from 0-100KW/m2.
  13. Provide the Self circulation cooling water to cool heat flux meter, without External tap water.
  14. Calibration Burner - to calibrate the rate of heat release measured by the apparatus using methane of 99.5% purity.
  15. Methane MFC, to control the flow rate of Methane automatically.
  16. OMRON PLC to control all movement such as Split Shutter, Spark Igniter etc.
  17. DAQ(Data Acquisition) Program controllable with the touch screen panel PC
  18. Provide 10units of PMMA samples for comparison testing

Hot Products

SR-601 12 Channels Curve Data Logger Data Recorder for Power System Introduction: SR-601 Data Logger ...
SR-601 Generator Motor Waveform Curve Testing Digital Signal Recorder Introduction: SR-601 Signal ...
SR-601 Instantaneous Power Signal Recorder Power Data Logger Introduction: SR-601 Signal Recorder is ...
Three Phase Power Quality Analyzer, Power Quality Data Logger Introduction: ETCR-5000 Three Phase ...
ETCR-5000 Three Phase Power Quality Analyzer and Power Quality Meter Introduction: ETCR-5000 Three ...
ETCR-5000 Energy Quality Meter Introduction: ETCR-5000 Energy Quality Meter is specially designed ...