Qingdao AIP Intelligent Instrument Co., Ltd |
|
Stator Vacuum Testing Machine Of Automotive Air Conditioner
Compressor Motor
1. Tests and introduction
2. Technical parameters
Surge | |
test ambient | comparatively vacuum |
output voltage setting range / precision | 500~3000V ±(3%×display value+8V) |
waveform comparison | area, area difference, corona and phase 3 waveforms displayed in the testing interface |
AC Hipot | |
output voltage setting range and precision | AC 200~3000V ±(2%×setting value+10V) |
breakdown current testing range / precision | 0.10~20.00mA ±(2%×display value+0.05 mA) |
breakdown current presetting alarm range | Max:0.10~20.00mA;Min:0.00~20.00mA |
test time range / resolution | 0.5~999.9s 0.1s/step |
Direction of rotation | |
rotation | CW, CCW, still |
DC winding resistance test | |
testing range and precision | 10.0mΩ~20KΩ ±(0.3%×display value+3 words) temperature compensation can be set. |
test time range / resolution | 0.5~999s 0.1s/step |
temperature compensation function | Yes |
temperature probe / range | DS18b20 -10.0℃~+50.0℃ |
precision | ±0.5°C(range: -10℃~+50℃) |
Insulation resistance | |
output voltage setting range / precision | DC 500V/1000V ±(2%×setting value+10V) |
insulation resistance testing range / precision | 1~500MΩ |
insulation resistance alarm setting range | Max: 0~500MΩ; Min: 1~500MΩ |
test time range / resolution | 0.5~999s 0.1s/step |
3. Introduction
4. After-sales service