Product Details

Safety Testing System / Electrical Testing System of appliances supporting MES
 
1. Application industry: home appliances & electric appliances such as air conditioner, refrigerator, washing machine, TV etc.
 
2. Test items: ground resistance, leakage current, insulation resistance, low voltage start, power, AC Hipot, DC withstand voltage
 
3. Technical parameters:

AC Hipot

Output voltage setting range/precision

AC 200~5000V ±(1.5%*setting value + 5 digit)

Breakdown current measuring range/precision

0.10~99.99mA ±(1.5%*displayed value + 5 digit)

Presetting breakdown current alarm range/precision

Up limit: 0.10~99.99mA;
Lower limit: 0.00~5.00mA

Testing time range/resolution

1~300S 1s/step

DC withstand voltage

Output voltage setting range/precision

DC 200~5000V ±(1.5%*setting value + 5 digit)

Breakdown current measuring range/precision

0.10~10.00mA ±(1.5%*displayed value + 5 digit)

Presetting breakdown current alarm range/precision

Up limit: 0.10~10.00mA;
Lower limit: 0.00~5.00mA

Testing time range/resolution

1~300S 1s/step

Insulation resistance

Output voltage setting range/precision

DC 500/1000V ±(1.5%*displayed value + 5 digit)

Insulation resistance measuring range/precision

1~2000MΩ Within 100MΩ:±(5%*displayed value + 3 digit);
Above 100MΩ:±(8%*displayed value + 8 digit);

Presetting insulation resistance alarm range/precision

Up limit: 0~2000MΩ; Lower limit: 1~2000MΩ

Testing time range/resolution

1-300s 1s/step

Grounding

Ground current output range/precision

AC 5.0~30.0A ±(1.5%*setting value + 5 digit)

Ground resistance measuring range/precision

10.0~600mΩ±(1.5%*displayed value + 5 digit)

Presetting ground resistance alarm range

Up limit: 5~10A 10.0~600mΩ; 11~25A 10.0~300mΩ; 26~30A 10.0~200mΩ
Lower limit: 0.0 ~100mΩ

Testing time/resolution

1~60s 1s/step

Leakage current

Output voltage

1.06 times of nominal voltage

Setting of leakage type

Dynamic leakage, static leakage, built-in body impedance network is optional, customized is available.

Output voltage measuring range/precision

AC 50~280V ±(0.5%*displayed value + 2 digit)

Leakage current measuring range/precision

0.05~20.00mA ±(1.5%*displayed value +0.02mA)

Presetting leakage current alarm range

Up limit: 0.05~20.00mA; Lower limit: 0.01~5.00mA

Testing time range/resolution

1~300s 1s/step

power

Output voltage

Equals input voltage

Output voltage measuring range/precision

AC 50~500V ±(0.5%*displayed value + 2 digit)

Output current measuring range/precision

AC 0.20~40.00A ±(0.5%*displayed value + 2 digit)

Power measuring range/precision

30~20000W ±(0.5%*displayed value + 5 digit)

Presetting power alarm range

Up limit: 30~20000W; Lower limit: 0~20000W

Testing time/resolution

1~300s 1s/step

Low voltage start

Output voltage

O.85 times of input voltage

Output voltage measuring range/precision

AC 50~500V ±(0.5%*displayed value + 2 digit)

Starting current measuring range/precision

AC 0.20~40.00A ±(0.5%*displayed value + 2 digit)

Presetting current alarm range

Up limit: 0.20~40.00A; Lower limit: 0.00~25.00A

Testing time/resolution

1~300s 1s/step

 
Accessories: power cord*1, foot switch*1(30A), clamp*2, test box1, input power wire*1, fuse tube*1.
 
4. Tips of electrical safety test
4.1 Attentions during dynamic leakage current measurement:

  • The voltage regulation index of isolation transformer should be minimized to avoid the measurement error cause by the change of power supply of tested product. It will be better to access an adjustable AC power source at the primary winding of isolation transformer, which can make sure applying a correct input voltage to the tested object.
  • The tested product should be placed on the insulation workbench without grounding if the isolation power source is not available.
  • To ensure the accuracy of measurement, the leakage current meter should contain a wide frequency detect range and true RMS conversion circuit, because the leakage current passed through insulated material contains sinusoidal, non-sinusoidal and higher harmonic components.

4.2 Attentions for the ground conduction resistance measurement:

  • Four-wire measurement method should be used in ground conduction testing, to eliminate contact thermo-electric potential and measurement error. The tester should have the function of automatically clearing wire resistance and contact resistance, which can ensure the accuracy of measurement.

Hot Products

4 in 1 Stator Testing Machine , IR/Hipot/Surge/Winding Resistance 1. Product introduction The stator ...
Stator Testing Machine For Compressor Motor Stator/Refrigerator/Air Conditioner Compressor Motor 1. ...
Fan Motor Stator Testing Machine Of Ceiling Fan / Table Fan / Wall Fan 1. Test: AC Hipot, Insulation ...
Stator Testing Machine For Compressor Motor Stator/Refrigerator/Air Conditioner Compressor Motor 1. ...
Stator Testing Machine For Compressor Motor Stator/Refrigerator/Air Conditioner Compressor Motor 1. ...
Stator Testing Machine For Compressor Motor Stator/Refrigerator/Air Conditioner Compressor Motor 1. ...