Home Companies Wetown Electric Group Co.,Ltd.

KEMA 160A 400V EM160 Molded Case Circuit Breaker

Wetown Electric Group Co.,Ltd.
Active Member

Contact Us

[China] country

Address: NO.1 Nanzi Road,Technology Park,XinbaTown,
Yangzhong City,Jiangsu Province,China

Contact name:Evan Xu

Inquir Now

Wetown Electric Group Co.,Ltd.

KEMA 160A 400V EM160 Molded Case Circuit Breaker

Country/Region china
City & Province jiangsu
Categories Battery Chargers
InquireNow

Product Details

EcoMaster Series Molded Case Circuit Breaker EM160 ln10-160A 400V

 

The new EcoMaster Series Molded Case circuit breaker, with four types of frame rated current covering 10A-1000A,breaking capacity up to 100kA(Icu) 75kA (Ics), has comprehensive intelligent tripping and residual current protection products.

 

The circuit breaker meets the following standards:

● IEC60947-1 and GB 14048.1-2006 general rules for low-voltage switchgear and control equipment

● IEC60947-2 and GB 14048.2-2008 low-voltage switchgear and control equipment circuit breakers

● IEC60947-4-1 and GB 14048.4 low-voltage switchgear and control equipment electromechanical contactors and motor starters

● The circuit breaker has passed the national compulsory "CCC" certification

● Obtained internationally recognized CB certificate

  1. EcoMaster series plastic case circuit breakers (hereinafter referred to as circuit breakers) are suitable for infrequent conversion and motor protection in circuits with AC 50Hz, rated working voltage 690V and below, and rated working current to 1000A
  2. The altitude of the installation site does not exceed 2000m
  3. The circuit breaker can be operated under the condition of ambient air temperature of -5℃∽+40℃, and the average value of 24 hours does not exceed 35℃ (except for special orders)
  4. The relative humidity of the air at the installation site does not exceed 50% when the maximum temperature is +40°C, and can have a higher relative humidity at a lower temperature, for example, up to 90% at 20°C. Special measures should be taken for the occasional condensation due to temperature changes
  5. Pollution degree is 3
  6. The installation category of the main circuit of the circuit breaker and the undervoltage release is Ⅲ, and the installation category of the other auxiliary circuits and control circuits is Ⅱ
  7. The circuit breaker can be installed vertically (ie vertical installation) or horizontally (ie horizontal installation)
  8. The circuit breaker should be installed and wired according to the product manual

                                                           

Hot Products

Fussion socket panel , W32Q/2Y , white Fussion socket panel is available in three colors: Amour ...
gold Fussion socket panel , W33Q / 2Y Fussion socket panel is available in three colors: Amour White...
Air Circuit Breaker EcoMaster series EA16 AC50/60HZ 50KA GB14048.2 Extremely high breaking capacity...
Air Circuit Breaker EcoMaster series EA40 AC50/60HZ GB14048.2 Extremely high breaking capacity...
EcoMaster Series Molded Case Circuit Breaker EM160 ln10-160A 400V The new EcoMaster Series Molded ...
EcoMaster Series Molded Case Circuit Breaker EM630 ln250-630A 400V The new EcoMaster Series Molded ...