Electric Heater Boiler 500Kw Heating Area: 5000-7000㎡ Hot Water Heater Electric Heating Equipment In Winter

 

The Electric Heater Boiler Has Some Advantages:

    1. Beautiful design: the electric heater and boiler must be the same from the inside to the outside from the design. From work to internal structure, they are serious handicrafts, saving more than 30% energy.

    2. No leakage: frequency conversion electromagnetic heating technology is adopted. A gap of 15-20mm between the heating part and the induction part is also known as space heating. So the real separation of water and electricity. It can be safely used.

    3. Water cooling technology: during electromagnetic heating, the IGBT of the electromagnetic component also consumes about 5% of the heat while working. If it is not recycled, it will cause great waste.

 

Electric Heater Boiler Technical Parameter:

Serial numberProduct modelCompanyLC-L-500kw
1Rated powerKW500
2Rated currentA760
3Heating area5000-7000
4input voltage50HZ380V
5Minimum flow of water pump configurationL/min800
6Hot water yield 50 ℃L/min567
7Design thermal efficiency98%
8Maximum water temperature85
9Low temperature protection temperature5
10Overall dimension (length * width * height)mm2600L*1400W*2000H
11Water inlet and outlet interfaceDN100

 

 

What If The Electric Heater Boiler Does Not Produce Hot Water:

    For the above two cases, let's make an analysis. If there is water circulation, but the water is cold; When encountering this problem, we should first open the door of the electromagnetic heating furnace and check whether the movement electromagnetic heater of the electric heater boiler works normally. If the normal electromagnetic heater fails, the fault code will be displayed. As long as we contact the manufacturer according to the fault code in the manual, we can help you solve it quickly.

    The second is that there is no circulating water, and the temperature sensor naturally cannot detect the water temperature, so it will be mistakenly thought that no hot water can be produced. We need to check whether there is a problem with the water pump, whether the water circulation is blocked, or whether the inner tank of the electric heater boiler has been used for too long, and the water quality is poor, and no soft water treatment is done, so the inner tank is blocked; In addition, the water temperature is too high to produce gas, and the gas is not exhausted in time. The air pressure causes the water to circulate. We need to check carefully and step by step to solve the problem of blocking the water pipe.

 

 

Hot Products

Electric Heater Boiler 70Kw Heating Area: 700-900 ㎡ Easy Operation, Intelligent Temperature Control ...
Electric Heater Boiler 60Kw Heating Area: 600-800 ㎡ Safe And Reliable, Safe To Use, No Leakage ...
Electric Heater Boiler 600Kw Heating Area: 6000-8000㎡ Safe And Reliable, Safe To Use, No Leakage ...
Electric Heater Boiler 500Kw Heating Area: 5000-7000㎡ Hot Water Heater Electric Heating Equipment In ...
Electric Heater Boiler 600Kw Electric Heating Equipment In Winter Electric Heater Boiler Technical ...
Electric Heater Boiler 450Kw Heating Area: 4500-6000㎡ Heating Furnace With Water And Electricity ...