Vertical Electric Steam Generator Boiler Installation Simple And
Fast Small
Introduce:
Gas-fired steam boiler refers to the steam boiler heated by burning
gas. Vertical steam boiler adopts combustion engine setting mode,
two-return structure, full fuel combustion, stable operation and
less space occupied by the boiler, at the same time, there is a
spoiler inserted in the smoke pipe, slow down the smoke exhaust
speed, increase heat exchange, high thermal efficiency of the
boiler, reduce user cost; Horizontal steam boiler for pot shell
type wet back downstream all three return fireworks tube structure,
indoor micro positive pressure combustion flame in the combustion,
fully extended, low combustion heat load, high combustion
efficiency, effectively reduces the exhaust temperature, saving
energy and reducing consumption, use a more economic, the waveform
furnace and threaded pipe structure, namely improve the boiler heat
intensity, and the heat transfer surface heat expansion needs,
scientific and reasonable, use for a long time.
Features:
1. Fire in the furnace, no open fire outside the furnace, and the
steam boiler shall be tested before leaving the factory. After
strict testing, the performance of the boiler, combustion
equipment, automatic control system and related devices shall be
tested; Equipped with high and low water level alarm and low water
level furnace shutdown, and automatic control of water pump.
2. Compact structure, single layer layout, less floor space, easy
installation.
3. The inlet and outlet are of the same caliber, which can reduce
the scaling of furnace bile and increase the service life.
4, the use of glass fiber cotton insulation, small heat loss, high
thermal efficiency.
5. Energy saving: Italian burner, low fuel consumption, low noise.
6. Convenience: automatic combustion and water level control,
automatic adjustment of air pressure and water level, automatic
heating and equipped with water shortage and low-pressure
protection of automatic fault detection of the burner.
7. the control system USES traditional electrical components,
convenient maintenance.
8. The gas steam boiler is manufactured as a whole and installed as
needed.
Maintenance:
I. Cleaning and maintenance measures
1. First open the burner door, remove the rear shell panel, and
unscrew the rear side cleaning port of the boiler.
2. Clean the gas pipeline with a wire brush.
3. Clean the combustion chamber with a soft brush.
4. For the residue in the boiler, screw the cleaning mouth, close
the burner door, and check whether the sealing ring is complete.
5. If the boiler is installed in the area with a temperature below
0℃, take the following protective measures: If the boiler room is
outside, reduce the indoor temperature to 15℃ or 18℃, and make the
boiler run all day. If no one is in the room for a long time, empty
the boiler.
Ⅱ. Boiler sewage treatment.
Boiler bottom blowdown can condense the flue gas. Smoke
condensation is due to smoke (diesel or natural gas) in water and
smoke temperature is too low, water production. Some of this water
is expelled from the chimney, some is absorbed by the chimney
walls, and the rest is deposited at the bottom of the chimney.
The amount of water produced is affected by the following factors:
the flue gas temperature, which should reach 170℃) the total
surface area of the chimney, the material of the chimney and the
insulation condition of the chimney.
Ⅲ. Maintenance of burner.
Maintenance of gas steam boiler and burner, maintenance after steam
supply. Because the combustion products will corrode the boiler and
clean up carbon deposition, so do not let the combustion products
in the boiler for too long.