Home Companies Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

High Static Pressure Duct Type Split System Air Conditioning Units 380V 50Hz

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
Active Member

Contact Us

[China] country

Address: Euroklimat Industrial Park, Huangjiang Dongguan Guangdong China 523766

Contact name:LENG Zhengliang

Inquir Now

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

High Static Pressure Duct Type Split System Air Conditioning Units 380V 50Hz

Country/Region china
City & Province dongguan guangdong
Categories Toilet Tissue
InquireNow

Product Details

EKDB 200ARX ~ EKDB 300ARX high static pressure duct type total fresh air handling Unit

 

 

Specifications:

 

 

ModelIndoor unit EKDB200ARXEKDB250ARXEKDB300ARX
Outdoor unit 2xEKAA100ARX2xEKAA125ARX2xEKAA150ARX
Rated cooling capacityW56,00065,00090,000
Rated heating capacityW52,00058,00082,000
Indoor unit circulating air flowm3/h5,8007,0009,000
Standard external static pressurePa200200250
Power supply 380V/3N~/50Hz
Indoor unit fan drive mode V-belt transmission
Total cooling input powerW201002480033800
Total heating input powerW197002440031200
Rated operating current for coolingA38.247.264.3
Rated operating current for heatingA3746.459.3
NoiseIndoor unitdB(A)≤64≤65≤65
Outdoor unitdB(A)≤65(single unit)≤65(single unit)≤68(single unit)
Outer dimensions (W × D × H)Indoor unitmm1719x965x7361719x965x7362242x1059x735
Outdoor unitmm2x990x840x18402x990x840x18402x1290x840x1840
WeightIndoor unitkg188198250
Outdoor unitkg2x2802x2852x300
Specifications for the condensed water
drainage pipe
 R1
Refrigerant type R22
Indoor and outdoor unit connection type Soldering
Connecting pipe specifications              External diameter of liquid tubemm2x15.882x15.882x15.88
External diameter of air tube                              mm2x28.62x28.62x34.9

 

Note:
■ The condition for the cooling capacity is as follows: The air dry bulb reads 34 oC and the wet bulb reads 28 oC. The condition for the
heating capacity is as follows: The dry bulb reads 7 oC and the wet bulb reads 6 oC. The cooling capacity and heating capacity change
according to the conditions. During model selection, you need to select a proper model based on local climatic conditions.
■ The external static pressure in the preceding table shows the specification for a standard unit. The static pressure changes depending on
customer requirements. For the specific value, see the reading on the nameplate.
■ The unit input power and current are based on the standard external static pressure. If the customer requires a different external static
pressure, check the nameplate on the unit for the power and current values.
■ The noise level is measured before the unit leaves factory. Due to environment noise and other factors in actual operation, the noise level
may be different from those listed in the preceding table.
■ The specifications may suffer change due to product update. The readings on the nameplate of the unit prevail.
■ For details about on-site power distribution and wiring for unit installation, see the nameplate or installation manual of the unit.

 

Description:

 

1. Intelligence and Fresh Air

 

  The EKDB-X total fresh air Handling system makes fresh air Handling more flexible. A separate fresh air system can directly supply fresh air to indoor in the air supply mode, or to the indoor unit as return air.

 

2. Long-distance Air Supply

 

    A high external static pressure ensures that air can be supplied to every room over a long distance. The air flow can be as high as 9000 m3/h to meet fresh air requirements in a large area.

 

 

Competitive Advantage:

 

The EKDB-X total fresh air Handling system best meets customer requirements for indoor air environment, intelligence, efficiency, and safety. A separate fresh air system can directly supply fresh air to indoor in the air supply mode, or to the indoor unit as return air, making fresh air Handling more flexible. The unit supports flexible combination and intelligent control, meets requirements for indoor space, and provides pleasant and comfortable experience. With its high intelligence and efficiency, low noise, delicate structure, easy operation, safe running, and convenient installation and maintenance, it is widely applicable to commercial scenarios such as hotels, malls, office buildings, and factory workshops.

 

Hot Products

68kW R410A Refrigerant Air Cooled Modular Chiller with DANFOSS Compressor Specifications: EKAC ...
R410a air cooled modular chiller 68KW/90KW/95KW/100KW/134KW/150KW Specifications: Basic Model ...
Features 1. Copeland scroll compressor or Danfoss scroll compressor 2. Plate heat exchanger or shell ...
Totally Heat Recovery Air Cooled Modular Chiller 130KW Features 1. Copeland scroll compressor or ...
Tropical area air cooled scroll chiller max working ambient temperature 56 C Features 1. 4 nos ...
EVI air cooled scroll chiller Features 1. 4 nos Copeland scroll compressors 2. Plate heat exchanger ...