Home Companies Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

Household 2 Ton / 3 Ton Heat Pump Package Unit HVAC Air Conditioning

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
Active Member

Contact Us

[China] country

Address: Euroklimat Industrial Park, Huangjiang Dongguan Guangdong China 523766

Contact name:LENG Zhengliang

Inquir Now

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

Household 2 Ton / 3 Ton Heat Pump Package Unit HVAC Air Conditioning

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

 

EKRV-B Series Inverter Multi-connected Household Central Air-conditioning

 

Parameter

 

Model EKRV035BR1EKRV040BR1EKRV050BR1EKRV060BR1EKRV070BR1
Power supply 220V~/50Hz380V/3N~/50HZ
Rated cooling capacitykW1012141618
Rated heating capacitykW1214161820
Rated cooling input powerkW2.633.23.884.545.21
Rated heating input powerkW2.853.293.924.655.29
Rated cooling input currentA1214.517.620.69.9
Rated heating input currentA131517.821.110
External dimensions (W×D×H)mm900×350×1030900×350×1030900×350×1160900×350×1290900×350×1420
Weight of the unitKg105105120135150
Operating noisedB(A)5454555657
PipingLiquid pipemm(in)Ф9.52
Air pipemm(in)Ф15.88Ф19.05
Pipe connection mode Evase connected to the threaded joint
Refrigerant R410A
Maximum number of connected indoor unitsSet78101113

 

 

Description:

 

Super High Air Supply Temperature in Low Temperature Environment
Scroll compressor enjoys a wider working temperature range than rotor compressor. Enhanced vapor injection can break through the limit of exhaust pressure and exhaust temperature in low temperature environment, to substantially increase the unit's heating capacity and the air supply temperature indoors.
When the ambient temperature is -25ºC, the maximum air supply temperature of EK inverter multi-connected indoor units can reach 41ºC.

 

Technology of Heating in Low Temperature Environment
With enhanced compressor frequency and the EVI function, the attenuation of heating capacity for EKRV-B series inverter multi-connected units under -15ºC ambient temperature is almost 0, which perfectly resolve the heating issue in cold areas in winters.

 

Lower Noise from Scroll Compressor
All series units adopt scroll DC inverter compressor. Compared with the common rotor inverter compressor, it features a more stable operating, less vibration, lower noise, and higher energy efficiency and longer life span.

 

Integrated Intelligent Temperature Control Technology
Quality temperature sensor can precisely detect the air supply temperature, air return temperature and indoor temperature. The indoor unit's control chip can intelligently sensor the change in temperature, and then automatically adjust the actual cooling capacity or heating capacity of the indoor unit to keep constant indoor temperature with a tiny variation of ±0.5ºC.

 

Broad Working Temperature Range
Advanced cooling system enables reliable running of EKRV-B series units. A cozy indoor environment is guaranteed, no matter in a summer when the outdoor temperature is 48ºC or in a winter when it is -30ºC.
Range of cooling operating temperature: 5~48ºC
Range of heating operating temperature: -30~29ºC

 

Exquisite Design, Pipe Connection From Three Sides
The clever design of unit enabled the refrigerant pipe to be directed out from the front side, rear side, or bottom of the unit. This is space-saving and facilitates the on-site construction.

 

Long Pipe and Large Elevation Difference

Item3.5HP/4HP/5HP6HP/7HP
Maximum equivalent pipe length (m)5070
Maximum elevation difference between
outdoor unit and indoor unit (m)
2030
Maximum elevation difference between
indoor units (m)
1515
Length from the first branch pipe to the
farthest indoor unit (m)
2530
Note: All pipe lengths here are equivalent lengths.  

 

Remote Monitor (Optional)
Remote intelligent control over smart phone/laptop
Intelligent software in cell phone can be used to implement remote monitor and control over air-conditioning units. Comprehensive and dynamic monitor of the running status of indoor and outdoor units make the life easier.
Centralized monitor through computer
Centralized monitor software for EK multi-connected units can perform centralized control of a maximum of 32 outdoor units.

 

Non-polar Communication
Advanced non-polar communication processing is adopted by connecting outdoor and indoor units with non-polar communication cables. This can prevent communication failure caused by incorrect cabling over communication ports during on-site construction.

 

Applications

hotels,entertainment centers, hospitals, restaurants, office buildings, cinemas,

factories, school supermarkets and so on.

Competitive Advantage:

EKRV unit using R410A refrigerant meets the energy saving and environmental protection.

Hot Products

68kW R410A Refrigerant Air Cooled Modular Chiller with DANFOSS Compressor Specifications: EKAC ...
R410a air cooled modular chiller 68KW/90KW/95KW/100KW/134KW/150KW Specifications: Basic Model ...
Features 1. Copeland scroll compressor or Danfoss scroll compressor 2. Plate heat exchanger or shell ...
Totally Heat Recovery Air Cooled Modular Chiller 130KW Features 1. Copeland scroll compressor or ...
Tropical area air cooled scroll chiller max working ambient temperature 56 C Features 1. 4 nos ...
EVI air cooled scroll chiller Features 1. 4 nos Copeland scroll compressors 2. Plate heat exchanger ...