Home Companies Tianjin Grewin Technology Co., Ltd

75A 100A 150A output 0.333v 5A split core current transformer current sensor for meter and energy system

Tianjin Grewin Technology Co., Ltd
Active Member

Contact Us

Address: Room907, No.1 Building, Yi Hao Qiao He Dong District, Tianjin, P.R.China

Phone: 86-22-84943756

Contact name:maggie shan

Inquir Now

Tianjin Grewin Technology Co., Ltd

75A 100A 150A output 0.333v 5A split core current transformer current sensor for meter and energy system

City & Province Tianjin Tianjin
InquireNow

Product Details

0.333-3.53V rated secondary output current transformer :

Model No 1 :GWCTSA010

Ratio : 3000:1

Rated input: 5A 10A 20A 50A 75A

Accuracy class: 1.0s 3.0s

Rated primary current:120A

Protection: 5 times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750A

Model No.2 :GWCTSA016

Ratio :3000:1

Rated input: 75A 100A 150A

Accuracy class: 0.5 1.0S

Rated accuracy limit primary current: 300A

Protection : 5 times Protection, 10 times protection

Model No. 3:GWCTSA024

Ratio : 3000:1


Rated input: 100A 150A 200A 250A


Accuracy class: 0.5 1.0S


Rated accuracy limit primary current: 540A

Protection : 5 times Protection, 10 times protection


Model No.4:GWCTSA035

Rated input: 200A 300A 400A 600A

Accuracy class: 0.5 1.0S

Rated accuracy limit primary current: 600A

Protection : 5 times Protection, 10 times protection

Frequency: 50--400Hz


0.333v transformer Key Specifications/Special Features:
A. Power rating: 0.6VA
Frequency range: 50/60Hz
Rated system voltage: 380V AC
Isolated voltage: 2,500V AC
Operating temperature range: -40 to +85°C
Storage temperature range: -45 to +90°C
Terminals: PC board or wire assembly
Conforms to IEC 60044-1
UL-/CE-approved and fully RoHS-compliant
Applications: current measurements and power meter


Split Core Current Transformers mA or 0.333-3.53V Rated Secondary Output

Part
Number

Ratio

Measuring

Protection

Frequency
(Hz)

Outline
Dimensions
ID-L-W-H
(mm)

Rated Input

Accuracy
Class

Rated Accuracy
Limit
Primary
Current
(A)

Accuracy
Class (Protection)

GWCTSA010

3000:1

5,10,20,50,75

1.0,3.0

120

5Protection,10P

50~400

10
-29.4-26.4-41.7

GWCTSA016

75,100,150

0.5,1.0

300

5P,10 Protection

50~400

16
-36.9-39.2-52.9

GWCTSA024

100,150,200,250

0.5,1.0

540

5P,10P

50~400

24
-51.2-47-70.2

GWCTSA035

200,300,400,600

0.5,1.0

600

5P,10P

50~400

35
-65.8-51.2-83.5

Hot Products

GWSCTK691A008retro-fit (Clamp-on) current transformer has been specially designed to facilitate ...
GWSCTK691A013retro-fit (Clamp-on) current transformer has been specially designed to facilitate ...
GWSCTK691A050retro-fit (Clamp-on) current transformer has been specially designed to facilitate ...
GWSCTK691A085retro-fit (Clamp-on) current transformer has been specially designed to facilitate ...
This product has been speciallydesigned to facilitate their installation in new or already existing ...