Home Companies Guangzhou Kenton Apparatus Co., Ltd.

OEM Biosafety Cabinet Class 2 Type A2 Bacteria Lab Safety Cabinet 110V 220V

Guangzhou Kenton Apparatus Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No. 6, Tongxing Street, Daxiang Industrial Zone, Renhe

Contact name:Brian Kwan

Inquir Now

Guangzhou Kenton Apparatus Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

OEM Biosafety Cabinet Class 2 Type A2 Bacteria Lab Safety Cabinet 110V 220V

Country/Region china
InquireNow

Product Details

OEM Class II A2 Biological Safety Cabinet Bacteria BioSafety Cabinet 110/220V For Lab

A2 B2 Biological safety cabinet:

Product introduction:
●Equipped with German EBM high air flow and low energy consumption fan, based on airflow mechanics principle, arc-shaped large-diameter inlet design to reduce turbulence generated, to ensure low noise operation of the system.
●Reasonable duct design, optimization of the plenum tank, with the design of micro-shaped mesh layer outflow wind deflector, non-convex, no dead ends, to ensure uniformity and stability of the airflow.
●Equipped with long life exhaust HEAP and down flow ULPA, >99.995% efficient at 0.12-micron sizes.
●BIOCASION series BSC have two types:
A2 Type:70% inner circulation, 30% exhaust.
B2 Type:100% exhaust.
Work zone width:1000mm and 1300mm

SAFELOGIC™ Plenum leak-proof technology:
●Around the work zone at the top and side wall plenum design, so that the discharge of polluting gases completely in a plenum environment, work with indoor backplane to a molding design, effective way to avoid the possibility of leakage.
●Equipped with the accurate pressure sensor to monitor the pressure of the working area, where there is abnormal situation such as breakage of the filter zone of negative pressure seal failure, the system will automatically stop the fan running, and through sound and light alarm prompts the operator, thus avoiding due to leakage caused damage.

BIOCASION™ Microcomputer controller system:
●The integrated LCD screens. Display inflow/down flow speed, pressure, filter life, failure alarm and other parameter status.
●The user-friendly design, with sterilization, lighting, interlock function, frond window over high alarm and front window closed then the fan shut down.
●Fan speed is adjustable according to need to adjust the appropriate amount of fan.

STABLEFLOW™ Stable fan speed system:
●High air flow fan, the system will automatically track and adjust the air volume and pressure, to balance the role of compensation, with the design of micro-shaped mesh layer outflow wind deflector, so that more air flow stability and uniformity.

Excellent imported sensor: Air Velocity Sensor and Pressure Plenum Sensor
●Imported air velocity sensors collect data of high precision, the performance of corrosion-resistant, anti-interference ability.
●Real-time monitoring and control cabinet status.
●Imported pressure plenum sensor responsive, effective monitoring the pressure of the work zone and plenum.

Ergonomically design:
●Ergonomically angled front. Increase operating comfort, reduce work fatigue.
●Equipped with splash electrical outlet. The Weight-Balance front window can move up and down freely.
●INSIDE lighting system to provide the best illumination angle and brightness, reducing visual fatigue.
●Front windows with explosion-proof, anti-ultraviolet tempered glass, to better protect the safety of the operator.

Modern manufacturing processes:
●Sheet metal parts use laser cutting and CNC bending technology. Cold-rolled sheets use three line of acidification anti-rust technology. Incubator surface use workmanship of spraying plastics.

Easy to clean:
●Working surface with anti-corrosion wear of SUS304 stainless steel plate forming a seamless, leak-proof, easy cleaning use.
●Under the working surface with the drain valve, easy to clean and emissions.

Convenient Maintenance:
●Removable combination tripod, easy to transport and move, Stand height adjustable.
●Eversion design of the front control panel to facilitate the electrical components, maintenance and replacement.
●In order to make the BSC able to achieve long-term safety requirements, it is recommended that the user to clean or replace the HEAP of the BSC in use for some time.

Technical Parameters:

Product Model

A2-
Biological safety cabinet

B2-
Biological safety cabinet

 

A2-1000G(D)

A2-1300G(D)

B2-1000G(D)

B2-1300G(D)

clean rating

International standard ISO14644.1 CLASS 5(US209E,CLASS 100)

inflow velocity

0.53m/s

0.56m/s

down flow velocity

0.35m/s

down flow velocity precision

±0.015m/s

noise level(dB)

≤65

vibration

≤3μm(X,Y,Z direction)

HEPA

efficiency 99.995%

light intensity(LX)

≥650

pressure difference range (Pa)

0~500

operate environment

environment temp.10-30℃,relative humidity under 70%, no obvious vibration and dust

external dimensions(H*W*D) (mm)

2060×1035×740

2060×1340×740

2120×1035×740

2120×1340×740

dimension of working zone(H*W*D) (mm)

670×965×560

670×1270×560

670×965×560

670×1260×560

power supply

Single-phase voltage source AC220V/50HZ

Power(W)

300

350

300

350

net weight(KG)

175

210

175

210

gross weight(KG)

195

235

195

235

package size (H*W*D) (mm)

1650×1205×910

1650×1510×910

1710×1205×910

1710×1510×910

 

Hot Products

110V Laboratory Dryer Oven Ultraviolet High Temperature Sterilization Drying Oven Usage Scenario ...
Medical Equipment Intelligent Blast Drying Sterilization Heating Oven Hot Sale Application: Constant ...
Professional high-temperature electrothermal oxidation free oven Hot air circulation clean room ...
Vertical Blowing Drying Oven Laboratory Sterilization lndustrial Drying Oven Oven Blowing Drying ...
Blast Thermostatic Industrial Oven Large High-Temperature Hot Air Oven Experimental Oven Laboratory ...
High Temperature 250 Degree Dryer Oven For Lab Testing Dryer Equipment GX series: Cavity preheating ...