Heavy Duty Diesel Generator 75kVA Silent Enclosed Genset with
Integrated-fuel-tank
Key advantages 75kVA diesel generator with an integrated fuel tank
offers several benefits for various applications.
Convenience and Extended Operation: The integrated fuel tank eliminates the need for an external fuel
source, providing convenience and ensuring extended operation
without frequent refueling. With a sufficient fuel capacity, the
generator can run for a significant duration, making it suitable
for applications where continuous power supply is required, such as
construction sites, events, or remote locations.
- Space-Saving Design: The integrated fuel tank is designed to be compact and seamlessly
integrated into the generator's structure. This space-saving design
helps optimize the overall footprint of the generator, making it
suitable for applications where space is limited, such as on boats,
in mobile units, or in compact industrial settings.
- Easy Maintenance: The integrated fuel tank design simplifies maintenance
procedures. It allows for easy access to the fuel tank, making
refueling and fuel level monitoring straightforward. Additionally,
integrated fuel tanks often come with built-in fuel filters,
ensuring fuel quality and reducing the risk of engine issues caused
by contaminated fuel.
- Improved Mobility: Generators with integrated fuel tanks offer enhanced mobility as
they do not rely on external fuel connections or storage systems.
This feature makes them more versatile and suitable for
applications that require frequent relocation or mobile power
solutions, such as construction projects or temporary events.
- Reduced Installation Complexity: With an integrated fuel tank, the installation process is
streamlined and simplified. There is no need to set up additional
fuel storage systems or connect external fuel lines, reducing
installation time, effort, and associated costs.
- Enhanced Safety: Integrated fuel tanks often come with safety features such as
fuel level sensors and automatic shut-off mechanisms. These
features ensure safe operation by preventing overfilling, fuel
leakage, or fuel-related accidents.
- Noise Reduction: Some generators with integrated fuel tanks feature silent type
enclosures that reduce noise and vibration during operation. This
makes them suitable for applications where noise control is
essential, such as residential areas, hospitals, or events.
7.Reliable Power Backup: A 75kVA diesel generator with an integrated fuel tank serves as a
reliable power backup solution. It can seamlessly provide backup
power during mains power outages, ensuring uninterrupted operation
of critical systems and equipment.
TECHNICAL DATA:
Technical Specification: |
75kVA Landbase Diesel Generator Set Specification |
Genset Model | TG83WCD6 | TG83WCSD6 |
Open | Silent |
Frequency | 60Hz |
Voltage | 480V |
Phase | 3 |
Rate Current | 90A |
Prime Power | 60kW / 75kVA |
Standby Power | 66kW / 83kVA |
Engine Model | Weichai WP4.1D80E201 |
Alternator Model | Leroy Somer TAL-A42-H |
Controller | DEIF SGC-420 |
Fuel Tank Type | 8 Hours Integrated-fuel-tank |
ATS | 100A Built-in Auto Transfer Switch |
Weight & Dimensions |
Length (mm) | 1900 | 2600 |
width (mm) | 850 | 1020 |
Height (mm) | 1250 | 1550 |
Weight (kgs) | 1100 | 1600 |
Engine Specification |
Brand | Weichai |
Engine Model | WP4.1D80E201 |
Prime/Standby power | 72kW / 80kW |
Injection | Indirect |
Aspiration | Turbocharged |
No. of cylinders | 4 |
Bore of Stroke (mm) | 105 x 118 |
Displacement (L) | 4.087 |
Cooling | water |
Compression Ratio | 16:1 |
Engine Oil capacity (L) | 8.3 |
Coolant Capacity ( In radiator) | 8.3 |
Governor | Electric |
Air Filter | Dry Element |
Fuel consumption | at 60Hz |
100% Load (L/h) | 17 |
75% Load (L/h) | 12.9 |
50% Load (L/h) | 8.6 |
25% Load (L/h) | 4.3 |
Alternator Specification |
Brand | Leroy Somer |
Model | TAL-A42-H |
Rate Output | 75kVA |
Pole | 4 |
Winding Connections | Star |
Insulation Class | H |
Enclosure | IP23 |
Altitude (m) | ≤1000 |
Voltage Regulator | AVR |
Steady State Voltage Regulator | 1% |
Bearing | Single |
Controller System |
Brand | DEIF |
Model | DEIF SGC-420 |
Functions | Control with AMF module |
Static with auto. battery charger |
Emergency stop push button |
ATS Connection |
OPTIONAL EQUIPMENTS |
ATS Box, Switch Box, Remote Control, Daily Fuel Tank, Engine
Heater, Water Heater, PMG Generator, Parallel Panel, Fuel-water
separator, Trailer Type, 3000Hours Spare Parts |
Heavy-duty diesel generator with a silent type enclosure and an
integrated fuel tank offers several advantages, including easy
maintenance:
- Silent Type Enclosure: The silent type enclosure is designed to minimize noise and
vibration during operation. It includes soundproofing materials and
insulation to reduce the noise levels, making it suitable for
applications where noise control is essential, such as residential
areas, hospitals, or events. The enclosure also provides protection
from environmental elements, ensuring the generator operates
reliably in various weather conditions.
- Heavy-Duty Performance: The generator is built to handle heavy-duty power demands. It is
capable of providing sustained power output for extended periods,
making it suitable for demanding applications such as construction
sites, industrial facilities, or large-scale events.
- Integrated Fuel Tank: The integrated fuel tank eliminates the need for an external fuel
supply, providing convenience and ease of use. The generator comes
with Integrated fuel tank of sufficient capacity to ensure extended
operation without frequent refueling. This feature is particularly
useful in remote locations or situations where a continuous power
supply is critical.
- Easy Maintenance: The integrated fuel tank design simplifies maintenance
procedures. It allows for easy access to the fuel tank, making
refueling and fuel level monitoring straightforward. Additionally,
integrated fuel tanks often come with built-in fuel filters,
ensuring fuel quality and reducing the risk of engine issues caused
by contaminated fuel.
- Convenient Monitoring and Control: The generator is equipped with a user-friendly control panel that
enables easy monitoring and control of various parameters. It
provides real-time information about voltage, frequency, load, and
other essential data, allowing operators to keep track of the
generator's performance and take necessary actions if required.
- Safety Features: Heavy-duty diesel generators often incorporate safety features
such as automatic shutdown mechanisms for low oil pressure, high
engine temperature, or other critical parameters. These safety
features protect the generator from potential damage and ensure the
safety of personnel operating in the vicinity.
- Reliable Power Backup: A heavy-duty diesel generator with a silent type enclosure and an
integrated fuel tank serves as a reliable power backup solution. It
can seamlessly provide backup power during mains power outages,
ensuring uninterrupted operation of critical systems and equipment.