Home Companies Shanghai S&D International Dental Co., Ltd.

21mm Rotary Endodontic Files Dental Hand Files Plugger Root Canal Filling Size #15-40

Shanghai S&D International Dental Co., Ltd.

Contact Us

[China] country

Trade Verify

Contact name:Alex Shi

Inquir Now

Shanghai S&D International Dental Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

21mm Rotary Endodontic Files Dental Hand Files Plugger Root Canal Filling Size #15-40

Country/Region china
InquireNow

Product Details

Dental Hand Use Endo Files Plugger Used For Root Canal Filling Stainless Steel Or NIckel Titannium Files With Size #15-40

 

S&D Plugger

1. This is a dental root canal dilator with a handle. it fills root canals
By welding pressure and material. It is a non-sterile instrument.
2. Main material
1) Cutting part: stainless steel (containing nickel and chromium)
2) Handle: Plastic

 

Purpose of use and function-efficacy
This is a dental instrument with a tapered working part that has
Circular form in cross section. for welding filler material
Pressure (mainly on the outside).


Specification
According to the ISO 13485 performance test, the twisting and bending durability of the product must exceed the specified value of our standard.

#15white
#20yellow
#25red
#30blue
#35green
#40black

 

How to use
According to its intended use, choose the most suitable FOREVER
PLUGGER and for filling material into root canals by means of welding pressure.


Precautions for use
1. To prevent infection, please autoclave the product and make sure to complete the sterilization before use.
2. Choose the most appropriate type for each case and follow the general approach.
3. Before use, make sure that the instruments outside the oral cavity are free from deformation, scratches and cracks.
4. The head of the product is thin, long or large, which may be broken or twisted. Because of this, be sure to avoid unreasonable angles and excessive pressure.
5. Wear safety glasses to protect your eyes from injury. Also, wear a dust mask to prevent inhaling dust.
6. Tie a chain, string or other utensil to the hole in the handle to prevent it from falling into the mouth.
7. Rubber dam or gauze should be used to prevent accidental ingestion and aspiration. Patients at high risk of accidental ingestion or aspiration should not be treated in a horizontal position, but should be treated in a seated position whenever possible.
8. Do not use this instrument for any purpose other than those mentioned above.
9. For dentist use only.
10. Dispose of this product as medical waste.
11. If the product is damaged or contaminated, please discard it.
12. After use, wash with a medical cleaner and a brush, and then wash away attached body fluids, tissues and other foreign objects.
13. When cleaning with an ultrasonic cleaner, please place the product on the bracket to avoid aging of the cutting part.
14. Be extra careful when using this product to avoid stabbing your fingers because it has sharp parts.
15. Avoid using unreasonable angles and excessive pressure.
16. This product may be corroded when it encounters NaOCl, EDTA, etc. for a long time.


Storage and usage period
1. Avoid storing in places with high temperature, humidity and direct sunlight. Keep away from liquids. Store it at room temperature.
2. Do not damage or perforate the packaging material.
3. The product is subject to improvement without prior notice. Inventory management implements the first-in first-out method.
4. Do not put it under a germicidal lamp to avoid deterioration.


Maintenance and Inspection
Sterilize this product by autoclaving according to the established method and duration of each use.
Sterilization method:
Put this product into a sterilization bag (or aluminum foil), place it on a sterilization tray or file rack, and perform autoclaving according to the following clauses.
Sterilization terms:
term(1) Temperature: 121°C Time: over 20 minutes
term(2) Temperature: 126°C Time: over 15 minutes
2. Do not use an autoclave that heats over 200 degrees Celsius including the drying process.
3. When using the instrument again, thoroughly clean and sterilize the foreign matter.
4. Regarding the use of medical cleaning agents, please operate in strict accordance with the manufacturer's instructions.
5. If the product is damaged or its performance deteriorates, please discard it.

Hot Products

Product Description: Dental Acrylic Resin Teeth are an ideal solution for dental prosthetic needs. ...
Product Description: Dental Acrylic Resin Teeth are dental false teeth made of acrylic resin which ...
Product Description: Dental Acrylic Resin Teeth are artificial dental teeth made of premium quality ...
Product Description: Dental Acrylic Resin Teeth are prosthetic dental teeth made from strong, ...
Product Description: Dental Acrylic Resin Teeth are false acrylic teeth designed for dental ...
Product Description: Dental Artificial Teeth - High Wear Resistance, Colored with VITA System, ...