4.3" TFT HMI PLC Combo 32bit CPU 408MHz Thermocouple Temperature Controller

Country/Region china
City & Province shenzhen
Categories Chargers
InquireNow

Product Details

60K colors resistive 4.3"TFT HMI PLC All-in-one 32bit CPU 408MHz Thermocouple Temperature Controller
 
In the field of personalized applications, coolmay technology provides users with a PLC application platform to create high-performance industrial integration control solutions for users, saving time and cost for users, improving efficiency and enhancing corporate competitiveness.
 
PRODUCT DESCRIPTION of HMI PLC ALL IN ONE
 

Feature:

 

  1.  

  2. ModelQM3G-43FH
    Dimension134*102*34mm
    Cutout size120*94mm
    Input24VDC
    Power Consumption4-6W
    HMI
    Feature60K colors resistive touch screen, supports portrait display
    Type4.3"TFT
    Display size97*56mm
    Resolution(pixels)480*272
    RAM64MB (Please inquire if requires storing historical data)
    ROM

    NOR Flash 8MB

     

    CPU32bit CPU 408MHz
    COM portsType-C HMI download port (can download PLC program through the USB penetrating function), RS232 port
    SoftwareCoolmay TPWorks HMI Programming Software
    PLC
    I/O level

    - Input: Passive NPN, public terminal isolated

    - Transistor output: Low level NPN, COM connect to negative

    - Relay output: Normally open dry contact

    DO type and load

     

    - MT: 2A/point, 4A/4 point COM, 5A/12 point COM
    MR: 2A/point, 5A/12 point COM

    High-speed countingSingle phase 6 channel 60KHz, or 2 AB 60KHz + 1 AB 10KHz, or 2 ABZ 60KHz + 1 AB phase 10KHz

    High-speed pulse

    (Only for MT models)

    8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz.

    High-speed counting + high-speed pulse < 480KHz

    COM port1x TYPE-C, 1x RS232, 1x RS485
    SoftwareCompatible with GX Developer8.86 and GX WORKS 2
    Detailed info. refer to: “Coolmay QM3G-FH All-in-One User Manual”, “Coolmay CX3G/FX3GC PLC Programming Manual”, “Coolmay TP HMI User Manual
     
     

 

Maintenance and service

  • Your products will be 18-month warranty excluding artificial damage.
  • You would receive unlimited support via video, phone or email.
  • OEM/ODM is supported, MOQ is 200 sets. More modules or functions can be customized as per your requirements.

FAQ

1.Precautions of using PLC transistor and relay
The PLC output is a common cathode output, the theoretical value is 1A, the actual use is less than 500mA, the COM wiring is negative, please use 24V voltage, there is no voltage output when it is used as a switch. If an external relay, the relay needs an external power supply.
The relay has a contact life, the theoretical value is 30W times, and the theoretical value of the external load does not exceed 5A. Frequently, the full load current may affect the service life, and there is no voltage out.
2.Precautions of Coolmay PLC output type selection
MT: indicates the transistor output, MR: indicates the relay output, and MRT: indicates the relay transistor mixed output.
The main differences between transistor output and relay output are:
(1)The difference in current load. At present, we use a transistor with a maximum current load of 500MA, and the maximum current load of the relay is 5A (the maximum relay current of the EX2N(S)/DX2N(S) series PLC is 3A);
(2)Output power: The transistor can only be connected to the DC24V power supply , and the relay can be connected to the DC24V and AC220V power supply ;
(3)Functional characteristics: If you need to send a pulse to drive a stepper motor, you should use the transistor output or the mixed output. Also if the output switch is active, it is recommended to use a transistor output;
(4)If both the relay and the transistor are available, it is recommended to use a transistor output because the transistor has no contact life limit and the lifetime will be longer than the relay as long as the current does not exceed the limit.

 

 
  1.  
















Hot Products

3.5 Inch HMI Control Panel Resistive Touch Screen Programmable PLC Light Grey 300cd/M² Modbus Rtu ...
4.3" Small size touch screen HMI control panel monitor RS232 RS485 107mA/24V IP65 front panel​ ...
800*480 pixels 5 inch hmi control panel 65536 colors HMI monitor with RS232 and WIFI PRODUCT ...
7-Inch HMI Control Panel 65536 Colors Light Grey 32bit CPU 408MHz Touchable HMI 800*480 Pixels ...
10-Inch IP65 Front Panel HMI Control Panel 222*125 32 Bit CPU 408MHz 4-Wire Resistive Panel 145mA...
3.5 Inch 320*240 Small Size HMI Control Panel 64MB RAM Support MODBUS​ PRODUCT DESCRIPTION Feature: ...