Home Companies Ningbo Tianan (Group) Co.,Ltd.

C - Gis Gas Insulated Switchgear 24kv Cubicle Type Metal Clad With Vcb

Ningbo Tianan (Group) Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: 3/F, Building B7 , 999 Yangfan Road,High-tech Zone, Ningbo, China 315040

Contact name:Lian Huanhuan

Inquir Now

Ningbo Tianan (Group) Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

C - Gis Gas Insulated Switchgear 24kv Cubicle Type Metal Clad With Vcb

Country/Region china
City & Province ningbo zhejiang
InquireNow

Product Details

C-GIS 24kV Cubicle type Metal - Clad Gas Insulated Switchgear With VCB

 

General:
XGN49Series lndoor Gas lnsulatlon MetaI-clad Switchgear(hereinafter called C-GlS)is a high quality product which the China power industry federation sole recommends technology from Korea Rijin electrical equipment industry corporation and it meets Chinese standards of GB/T11022-1999 and GB3906-2006C-GlS,has the characteristics of high reliability,free from maintenance and small cover area.

Purpose:
The GIS is suitable for power plant, substation, combined substation and electric power system, which is three phase indoor AC single busbar and sectioning single busbar with 50Hz, 35kV rated voltage, used to control, accept and distribute electric power.

Service ambient conditions:
1. Air temperature: Max: +40, Min: -25 (average is not more than 35 in 24 hours)
2. Altitude above sea level: <= 5000m
3. Air humidity:
The average relative humidity measured in 24 hours is not more than 95%,
The average relative humidity per month is not more than 90%,
average water vapor pressure measured in 24 hours is not more than 2.2kPa,
average water vapor pressure per month is not more than 1.8 kPa.
4. Without frequent heavy vibration.

Parameters :

NameUnitParameters
Rated VoltagekV24
Rated CurrentA1250 2000 2500
Rated FrequencyHz50/60
Rated Power Frequency Withstand Voltage (1min)Between Phases, Phase to EarthkV65
Insulation DistanceKV79
Rated Lightning Impulse Withstand VoltageBetween Phases, Phase to EarthkV125
To open gap145
Secondary Circuit Power Frequency Withstand Voltage (1min)V2000
Rated Short-circuit Breaking CurrentkA20 25 31.5
Rated Short-circuit Making CurrentkA50 63 80
Rated Short-time Withstand Current 4SkA/S20/4 25/4 31.5/4
Rated Peak Withstand CurrentkA50 63 80
Enclosure Protection Class (Air Inflation Shell/LV Cubicle) IP67/IP4X
Main Circuit Resistance Each PhaseμΩ≤250
Rated Operating Pressure of SF6 Gas (Gage pressure for 20ºC )Mpa0.05
Minimum Operating Pressure of SF6 Gas (Gage pressure for 20ºC )Mpa0.03
SF6 Gas Annual Gas Leakage Rate%≤0.5
Auxiliary Circuit Rated Operating VoltageVDC110/220,AC220
Enclosure Dimension (Width*Depth*Height)mm

600*1300*2350

(800*1600*2550)

 

 

 

Hot Products

6.6 kV SCB Three Phase Cast Resin Dry Type Distribution Transformer Product Description SC(B)10 ...
Power Distribution Air Cooled Transformer Scb Series Dry Type Electrical Transformers Overviews SG(H...
125kva Industrial Dry Power Transformer 11kv Distribution electrical power transformer​ Overview ...
6.6 kV SCB Three Phase Cast Resin Dry Type Distribution Transformer Product Description SC(B)10 ...
Insulating Non-encapsulated Environmental Cast Resin Dry Type Transformer Overview: Insulating Non...
10kV Oil Immersed Off - Load Tap Changer Power Distribution Transformer General: 11KV class ...