11KVPad Mounted Transformer Step Up Transformer Photovoltaic Power Generation

Country/Region china
City & Province ningbo zhejiang
InquireNow

Product Details

Product Description

Summarize
ZGS-Z.G-/11 series wind power combined transformer is a special power equipment integrating step-up transformer, HV current limited fuse, load switch, LV switch and related auxiliary equipments. It transforms the 0.69kV voltage produced by wind power motor into 35kV,and output the electricity through 35KV cable circuit, which is the ideal equipment in wind power complete set equipment.

Normal ambient conditions for service
Altitude shall be within 2000m
Ambient temperature range shall be : -40ºC~+40ºC
Outdoor wind speed shall not exceeds 35m/s
Relative humidity: daily average value shall not exceed 95%, monthly average value 90%
Installation site: indoor
Service environment: installed in sites with no fire or explosion danger, serious fifth, chemical corrosion and fierce vibration.
When transcend the above normal ambient conditions for service, users can negotiate with us to solve.


Product technical parameter
Parameter of 11kV oil immersed load switch
Table 1

S/N
NameUnitParameter
1Rated voltageKV12
2Rated currentA315630
3Rated frequencyHz50
4Rated short-circuit withstand currentkA/2s12.520
5Rated peak withstand currentkA31.550
6Mechanical endurancetimes>2000
71 min power withstand voltage (phase-to-phase, phase-to-earth)kV42
8Lightning impulse level (phase-to-phase, phase-to-earth)KV75
      

 

Parameter of 11kV fuse
Table 2

Rated voltageFuse rated current ARated Max. breaking current kARemark
15.563, 80,100,125,15050off lineback-up type
15.56.3,10,16,25,40,63,100,1402.5Plug -in
    

Parameter of lightning arrester
Table 3

Rated voltageContinuous operating voltageDC reference voltage (1mA)Nominal discharging currentNominal discharging current residual2ms square-wave current withstand value
17kV13.6kV≥24kV5kA(peak value)≤45kV (peak value)≥250A(peak value)

Condensation controller and other auxiliary equipment can be added in the body as per clients' requests.
Note: As per different requirement from client, the capacity of transformer can be customized.
 

Hot Products

35KV Transformer Station Resin Insulation Dry - Type Power Transformer Overview SCB series resin ...
35KV Transformer Station Resin Insulation Dry - Type Power Transformer Overview This product adopts ...
6 ~ 35 KV / 30 ~ 2500 KVA Resin Casting Dry Type Distribution Transformer ​ General: As the ...
30 ~ 2500 KVA Thin - Insulation Resin Cast Dry Type Power Transformer General: 10 KV grade SCB10, ...
Indoor 10 KV Three phase Resin Cast Dry - type Power Distribution Transformer​ Overview: SC(B)10 ...
35kv / 20kv / 10kv Electrical Dry Type Distribution Transformer NINGBO TIANAN (GROUP) CO., LTD. ...