Home Companies Innovation Electronic Co.,Ltd

Load Cell IPW6C 3-40kg Static Weighing Aluminum weight sensor 2mv/v C6 for Counting Scale IP67

Innovation Electronic Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: #201,Shunda Road, Yuhang Economic Area, Hangzhou,China

Contact name:TINA LIU

Inquir Now

Innovation Electronic Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Load Cell IPW6C 3-40kg Static Weighing Aluminum weight sensor 2mv/v C6 for Counting Scale IP67

Country/Region china
City & Province hangzhou zhejiang
Categories Used Measuring & Analysing Instruments
InquireNow

Product Details

IPW6C 3KG TO 40kg single point load cell aluminum material for Static Weighing OIML C3 C6

40kg Counting Scale Portable Load Cell Sensor For Weight Measurement ODM

 

 

Special features
 

--  Accuracy class C3 with OIML-R60 test report

--  Off center load compensated (OIML R 76)

--  Max. capacities: 3 kg ... 40 kg

--  Degree of protection IP67(according to EN 60 529)

--  Shielded connection cable

--  Optimized for static weighing applications

 

Optional:
 

--  Accuracy class C6 with OIML-R60 test report

--  Connection cable in six wire circuit

--  Different cable lengths

−   Aligned output, suitable for connectionin parallel

 
TypeIPW6C
Accuracy class1)C3; C3MR
Number of load cell intervals (nLC)3000
Maximum capacity (Emax)2))kg3510152030-40 

Minimum LC verification interval (vmin)

Accuracy class C3

g10102020505050

Temperature effect on

zero balance (TK0)

Accuracy class C3

 

% v.

Cn /

10 K

 

±0.0233±0.0280±0.0280±0.0186±0.0350±0.0233±0.0350

Minimum LC verification interval (vmin)

Accuracy class C3MR

g0.20.511225

Temperature effect on

zero balance (TK0)

Accuracy class C3MR

% v.

Cn /

10 K

 

±0.0093±0.0140±0.0140±0.0093±0.0140±0.0093±0.0175
Max. platform sizemm300 x 300
Sensitivity (Cn)mV/V2.0±0.2
Zero balance0±0.12

Temperature effect on

sensitivity (TKC)3)

Temperature range

+20 ... +40℃ [+68 ... +104℉]

−10 ... +20℃ [+14 ... +68℉]

% v.

Cn /

10 K

 

±0.0175

±0.0117

Hysteresis error (dhy)3)% of Cn±0.0166
Non-linearity (dlin)3)±0.0166
Minimum dead load output return (DR)±0.0245
Off center load error4)±0.0233
Input resistance (RLC)Ω300 ... 500
Output resistance (R0)300 ... 500
Reference excitation voltage (Uref)V5
Nominal range of excitation voltage (BU)1...12
Insulation resistance (Ris) at 100 VDC> 2
Nominal temp. range (BT)

°C

[°F]

−10 ... +40 [+14 ... +104]
Service temp. range (Btu)−10 ... +50 [+14 ... +122]
Storage temp. range (Btl)−25 ... +70 [−13 ... +158]

Safe load limit (EL ), at max.

100mm eccentricity

% of

Emax

150

100

Lateral load limit (Elq), static

% of

Emax

300
Breaking load (Ed)300
Deflection at Emax (snom), approx.mm< 0.5
Weight (G), approx.kg0.25

Protection class according to

EN 60 529 (IEC 529)

 IP67

Material: Measuring element

Coating

Cable sheath

 

Aluminum

Silicone rubber

PVC

 
 
 
 
 
 

Hot Products

IN-1004 300g 600g 1000g 1200g 2000g 3000g for jewellery scale and electronic balance replace VISHAY ...
IN-1022 3kg 5kg 6kg 10kg 15kg 35kg Single Point Load Cell for price computer scale replace VISHAY ...
IPW6C 3 to 40kg Single Point Load Cell for price computer scale Dust - Free Single Point Load Cell , ...
IN PW15AH 10KG 20KG 50KG 100kg single point stainless steel load cell for check weigher and filling ...
IN-PW10A 0.05 to 10t Single Point Load Cell for platform scale Vishay-Tedea 3400 load cell special ...
IN-L6H5 4 to 20kg Single Point Load Cell for platform scales special features: Rated load: 100~500...